Keepower Large User Manual

Manual is about: Keepower Battery Charger

Summary of Large

  • Page 1

    Small, medium, large and xl-con keepower battery charger user guide.

  • Page 2: Small 1A Or 4A/12V

    Small, medium, large and xl-con small 1a or 4a/12v medium 8a/12v clamp cable 0.75mm² 74753607 2.50mm² 74753608 motorbike cable 0.75mm² 74753580 2.50mm² 74753581 mains cable mains cable xl-con 30a/12v 15a/24v temperature sensor mains cable the keepower charger kit large 15a/12v cigarette cable max 8a...

  • Page 3: English

    Small, medium, large and xl-con english • battery acid is highly corrosive. Acid on the clothes should be rinsed off immediately in running water. Acid on the skin or in the eyes, rinse thoroughly in running water and contact a doctor. • a battery produces explosive gases during charging and good ve...

  • Page 4

    Small, medium, large and xl-con flash light button flash light full medium low discharged battery deep discharged bike charging cold charging normal charging battery indicator error indicator charging mode: xl-con 30a/12v 15a/24v selection button supply mode (14.8v/29.6v) (14.4v/28.8v) charging mode...

  • Page 5

    Small, medium, large and xl-con selection of the different charging modes normal charging is used on normal batteries (wet, open type), maintenance-free, gel and sealed battery with a gas limit at 14.0v/12v in bulk mode, and 14.4v/12v in aftercharge mode. Normal charging is used on normal batteries ...

  • Page 6

    Small, medium, large and xl-con connect the clamps to the battery. • red to + terminal • black to - terminal select charging mode. • select charging mode, and charging will start. • chargingfinishwhenledconstantlight. • charger can be constant connected. Before disconnection. • switch off mains supp...

  • Page 7: Keepower Chargers

    Small, medium, large and xl-con small medium large xl-con keepower chargers the charger can be installed in 4 different positions. How to install the charger this user guide can be used for 4 variants of the keepower chargers. Thefirstpartoftheuserguideisageneralpartandthelastpartisspecialfor the xl...

  • Page 8

    Small, medium, large and xl-con the intelligent charging curve soft charge(indication:dischargedledflashing): the “soft charge” phase is used when the battery is deep dis- charged. The battery is charged until it is ready to receive normal charging (12.0v) and then the normal charging is started. De...

  • Page 9

    Small, medium, large and xl-con after charging(indication:fullledflashing): the “after charging” phase is the phase where the battery under a constant voltage is charged to app. 100% of the full capacity. The voltage is raised 0.4v compared to the bulk charging phase. Testing (indication:fullledflas...

  • Page 10: Error Indication

    Small, medium, large and xl-con error indication warning flashing: • clamps not connected to battery. • mains cable not plugged in or mains switch not switched on. • supply: overload, i.E. The voltage is dropping due to loading with more than the nominal current (8/15/30a). Warning constant: before ...

  • Page 11: Flash Light

    Small, medium, large and xl-con flash light thechargercontainsaflashlighttobeusedasasmallworkinglampwhen using the charger in a dark room. Theflashlightisusinganinternalbatterysoitcanbeusedwithorwithoutthe mains connected. Theflashlightcanbereplaced.Pleaseordersparepartno.45004105 (see picture 2). G...

  • Page 12: Technical Data

    Small, medium, large and xl-con technical data nominal battery voltage charge current battery size max. Total input power input voltage (mains voltage) ripple voltage (charging old battery with 40% capacity left) current ripple (charging old battery with 40% capacity left) ipclassification keepower ...