Keepower Large User Manual - page 8
Small, Medium, Large and XL-Con
The intelligent charging curve
Soft charge(Indication:DischargedLEDflashing):
The “soft charge” phase is used when the battery is deep dis-
charged. The battery is charged until it is ready to receive normal
charging (12.0V) and then the normal charging is started.
Desulphation(Indication:DischargedLEDflashing):
The “desulphation” phase is used if the battery has not been used
for a longer period.
Bulk charging (Indication:LowLEDflashing):
The “bulk” phase is the phase where the battery under a constant
current is charged to app. 85% of the full capacity.
Absorption(Indication:MediumLEDflashing):
The “absorption” phase is the phase where the battery under a
constant voltage is charged to app. 98% of the full capacity.
Testing
Soft charge
Desulphation
Bulk charge
Absorption
After charge
Testing
Maintenance
Maintenance