KeepRite DLCCAR Installation instruction

Other manuals for DLCCAR: Service Manual
Manual is about: High Wall Ductless Split System - Sizes 09 to 36

Summary of DLCCAR

  • Page 1

    Dlfcab / dlccar / dlfchb / dlcchr dlfdab / dlcdar / dlfdhb / dlcdhr high- wall ductless split system sizes 09 - 36 installation instruction note: read the entire instruction manual before starting the installation. Table of contents page safety considerations 2 . . . . . . . . . . . . . . . . . . . ...

  • Page 2: Warning

    2 safety considerations installing, starting up, and servicing air- conditioning equipment can be hazardous due to system pressures, electrical components, and equipment location (roofs, elevated structures, etc.). Only trained, qualified installers and service mechanics should install, start- up, a...

  • Page 3

    3 piping and refrigerant tables dlfcab / dlccar / dlfchb / dlcchr table 2—piping information dlfcab / dlccar / dlfchb / dlcchr system size 9k 12k 9k 12k 18k 24k 30k 36k voltage 115/1/60 115/1/60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 min. Piping length ft 10 10...

  • Page 4

    4 piping and refrigerant tables dlfdab / dlcdar / dlfdhb / dlcdhr table 4— piping information dlfdab / dlcdar / dlfdhb / dlcdhr system size 9k 12k 9k 12k 18k 24k 30k* 36k* voltage 115/1/60 115/1/60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 min. Piping length ft 10...

  • Page 5: Caution

    5 all wires must be sized per nec (national electrical code) or cec (canadian electrical code) and local codes. Use electrical data table mca (minimum circuit amps) and mocp (maximum over current protection) to correctly size the wires and the disconnect fuse or breakers respectively. Per caution no...

  • Page 6

    6 dimensions - indoor fig. 1 - indoor unit dimensions table 8—dlfcab / dlccar / dlfchb / dlcchr system size 9k 12k 9k 12k 18k 24k 30k 36k voltage 115/1/60 115/1/60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 height (h) in 11.4 11.4 11.4 11.4 11.8 12.8 12.8 12.8 widt...

  • Page 7

    7 dimensions - outdoor n m h d w s p fig. 3 - outdoor unit table 12—dlfcab / dlccar / dlfchb / dlcchr system size 9k 12k 9k 12k 18k 24k 30k 36k voltage 115/1/60 115/1/60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 height (h) in 21.3 23.3 21.3 23.3 27.6 31.1 31.1 31....

  • Page 8

    8 clearances - indoor 6" (0.15m) min. 5" (0.13m) min. 6' 5" (0.13m) min. (1.8m) ceiling floor fig. 4 - indoor unit clearances clearances - outdoor a d b air-outlet air-inlet c e fig. 5 - outdoor unit clearances table 14—outdoor clearances unit minimum value in. (mm) a 24 (609) b 24 (609) c 24 (609) ...

  • Page 9: Caution

    9 installation guide ideal installation locations include: indoor unit s a location where there are no obstacles near inlet and outlet area. S a location which can bear the weight of indoor unit. S do not install indoor units near a direct source of heat such as direct sunlight or a heating applianc...

  • Page 10: Caution

    10 piping guide: s do not open service valves or remove protective caps from tubing ends until all the connections are made. S bend tubing with bending tools to avoid kinks and flat spots. S keep the tubing free of dirt, sand, moisture, and other contaminants to avoid damaging the refrigerant system...

  • Page 11: Caution

    11 install all power, interconnecting wiring, and piping to indoor unit 1. Run interconnecting piping and wiring from outdoor unit to indoor unit. 2. Pass interconnecting cable through hole in wall (outside to inside). 3. Lift indoor unit into position and route piping and drain through hole in wall...

  • Page 12

    12 outdoor unit indoor unit refrigerant service valve low side high side a b c d a07360 fig. 16 - service valve manifold gage 500 microns low side valve high side valve charge hose charge hose vacuum pump low side valve a07361 fig. 17 - manifold deep vacuum method the deep vacuum method requires a v...

  • Page 13

    13 start- up test operation perform test operation after completing gas leak and electrical safety check. 1. Push the “on/off” button on remote control to begin testing. Note: a protection feature prevents the air conditioner from being activated for approximately 3 minutes. 2. Push mode button, sel...

  • Page 14

    14 wiring diagrams d n g ' l s ' n d n g n l ' l s ' n ground 0 6 - 1 - 5 1 1 c d v w o l 0 6 - 1 - 5 1 1 0 6 - 1 - 5 1 1 0 6 - 1 - 5 1 1 0 6 - 1 - 5 1 1 c d v w o l 0 6 - 1 - 5 1 1 power from outdoor unit ground k c o l b l a n i m r e t t i n u r o o d n i j 2 1 & 9 0 * f l d k c o l b l a n i m r...

  • Page 15

    15 troubleshooting this unit has on- board diagnostics. Error codes appear on the led display on the front panel of the indoor unit in place of the temperature display. Error codes are also displayed on the outdoor unit microprocessor board with colored led lights. The table below explains the error...

  • Page 16

    16 copyright 2015 international comfort products lewisburg, tn 37091 usa manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. Edition date: 06/15 catalog no:42101942000 replaces: new.