Keison KANE200 Manual - page 19
17 KANE200
series
manual
BAT
Displays the Battery power available in %
When the LO BAT symbol appears this indicates the batteries are at
less than 10% of charge and should be replaced, readings may be
affected if used with low power batteries. Warning: all stored
readings are lost when the batteries are removed or become
exhausted.
DATE :
Date shown as day, month and year. The order can be changed using
the menu function. Date is recorded when each combustion test is
printed.
TIME :
The time is shown in hours and minutes, expressed in “Military”
time or the 24hr clock. Time is recorded when each combustion test
is printed.
Note! When changing the batteries on the instrument the memory
will store the date and time for up to one minute, if outside this
time it may be necessary to re-enter the details.
Date and time may also need to be reset if re-chargeable batteries are
allowed to totally discharge.
SYMBOLS used on the display's top line
P
Poison Index: measured CO divided by calculated CO
2
multiplied by
100
R CO/CO
2
Ratio: measured CO divided by calculated CO
2
lamda
Excess Air
AMB
Either the internal temperature of the meter or the inlet temperature as
measured during the start up sequence
loss triangle Loss%: losses = 100 minus efficiency%
delta T
Nett Temperature.
TF
Flue
Temperature
eff symbol
Efficiency %
Ħ mg/m
3
normalised