Italiano english libretto di istruzioni e installazione use and installation instruction.
Grazie per aver acquistato un climatizzatore d’aria hisense, le raccomandiamo di leggere attentamente questo manuale d’uso e di installazione prima di installare ed utilizzare questo apparecchio, e, di conservare questo manuale in caso di eventuali future necessità. Le raccomandiamo inoltre di attiv...
Indicatore super 7.
Use and care manual 1 r4 0a refrigerant 1 r4 0a f a re riger nt 1 r4 0a refrigerant 1 r4 0a f a re riger nt thank you very much for purchasing hisense air conditioner, please read this use and care manual carefully before installing and using this appliance and keep this manual for future reference....
1 preparation before use before using the air conditioner, be sure to check and preset the following. Remote controller(rc) presetting auto-restart function the air conditioner has auto-restart function. Each time after the remote controller replaces batteries or is energized, remote controller auto...
Safety precautions symbols in this use and care manual are interpreted as shown below. Be sure not to do. The feature of the appliance, instead of a fault. Pay attention to such a situation. Grounding is essential. Be sure to follow this instruction. Do not use the power supply circuit breaker or pu...
Air intake air outlet vertical adjustment louver horizontal adjustment louver air filter remote controller open panel display panel figures in the manual are only simple representation of the appliance, its may not comply with the appearance of the air conditioner you purchased. Charcoal precipitato...
The symbols may be different from these models, but the functions are similar. Display introduction 4 1 2 3 4 5 6 running indicator it lights up when the ac is running. It flashes during defrosting. 2 timer indicator it lights up during set time. 3 sleep indicator it lights up in sleep mode and the ...
The symbols may be different from these models, but the functions are similar. Display introduction 5 1 2 3 4 5 6 1 1 2 2 3 3 4 4 5 5 6 6 ns series vt series vq series.
The symbols may be different from these models, but the functions are similar. Display introduction 6 1 2 3 4 5 6 1 2 3 4 5 6 timer comp. Run sleep ul series uq series up series 6 timer comp. Run sleep 1 2 3 4 5.
8 emergency button 8 the symbols may be different from these models, but the functions are similar. 7 display introduction off you can stop the unit immediately by pressing the button. Force cooling : you can force the unit to run in cooling mode by pressing the button for 5 seconds. And in this sta...
The remote controller transmits signals to the system. - h1 remote controller 8 1 2 4 3 13 12 5 6 11 7 8 9 10 super button swing button fan button room temperature setting buttons sleep button dimmer button clock button on/off button smart button mode button timer on/off button used to start or stop...
How to use 9 to operate the room air conditioner, aim the remote controller to the signal receptor. The remote controller will operate the air conditioner at a distance of up to 8m when pointing at signal receptor of indoor unit. Remote controller remote controller signal receptor mo de l c c o k e ...
Each time mode button is pressed, the operation mode is changed in sequence: each time the "fan" button is pressed, the fan speed is changed in sequence: 18 ~32 ℃ ℃ heating mode is not available for cooling only air conditioner. Heating cooling dry fan only selecting mode fan mode auto high medium l...
5 airflow direction control vertical airflow is automatically adjusted to a certain angle in accordance with the operation mode after turning on the unit. The direction of airflow can be also adjusted to your own requirement by pressing the "swing" button of the remote controller. Operation mode dir...
Indoor temperature indoor temperature smart button is ineffective in super mode. Target temperature target temperature 21 ℃ or below 26 ℃ or below 22 ℃ 22 ℃ 26 ℃ 26 ℃ over 26 ℃ over 26 ℃ 21 ℃-23℃ 23 ℃-26℃ your feeling what you can do in smart mode button adjustment procedure operation mode operation...
13 timer mode how to set timer on how to cancle timer on timer on button can be used to set the timer programming as wished in order to switch on the appliance at your desired time. Press timer on button, "12:00 on" flashes on the lcd, then you can press the or buttons to select your desired time fo...
14 operation instructions 11 sleep mode super mode sleep mode can be set in cooling, heating or drying operation mode, this function gives you a more comfortable environment for sleep. The appliance will stop operation automatically after operating for 8 hours. In sleep mode, note: heating is not av...
The remote controller transmits signals to the system. Remote controller 15 1 2 4 3 13 12 5 6 11 7 8 9 10 super button swing button fan button room temperature setting buttons sleep button clock button on/off button smart button mode button timer on/off button used to start or stop the fast cooling....
How to insert the batteries how to use remove the battery cover according to the arrow direction. Insert new batteries making sure that the (+) and (-) of battery are matched correctly. Reattach the cover by sliding it back into position. Note: use 2 lr03 aaa(1.5volt) batteries. Do not use rechargea...
Each time mode button is pressed, the operation mode is changed in sequence: each time the "fan" button is pressed, the fan speed is changed in sequence: 18 ℃ ~32 ℃ heating mode is not available for cooling only air conditioner. Heating cooling dry fan only selecting mode fan mode auto high medium l...
5 airflow direction control vertical airflow is automatically adjusted to a certain angle in accordance with the operation mode after turning on the unit. The direction of airflow can be also adjusted to your own requirement by pressing the "swing" button of the remote controller. Operation mode dir...
Indoor temperature smart button is ineffective in super mode. Target temperature 21 ℃ or below 22 ℃ 22 ℃ 26 ℃ over 26 ℃ 21 ℃-23℃ 23 ℃-26℃ your feeling what you can do in smart mode button adjustment procedure operation mode heating fan only dry room temperature decrease 1.5 ℃ after operate for 3 min...
20 timer mode how to set timer on how to cancel timer on timer on button can be used to set the timer programming as wished in order to switch on the appliance at your desired time. Press timer on button, "on 12:00" flashes on the lcd, then you can press the or buttons to select your desired time fo...
1121 operation instructions 11 sleep mode super mode sleep mode can be set in cooling, heating,drying operation mode. This function gives you a more comfortable environment for sleep. The appliance will stop operation automatically after operating for 8 hours. In sleep mode, note: heating is not ava...
The remote controller transmits signals to the system. Remote controller 22 1 2 4 3 13 12 5 6 11 7 8 9 10 super button swing button fan button room temperature setting buttons sleep button i feel button clock button on/off button smart button mode button timer on/off button used to start or stop the...
How to insert the batteries how to use remove the battery cover according to the arrow direction. Insert new batteries making sure that the (+) and (-) of battery are matched correctly. Reattach the cover by sliding it back into position. Note: use 2 lr03 aaa(1.5volt) batteries. Do not use rechargea...
Each time mode button is pressed, the operation mode is changed in sequence: each time the "fan" button is pressed, the fan speed is changed in sequence: 18 ℃ ~32 ℃ heating mode is not available for cooling only air conditioner. Heating cooling dry fan only selecting mode fan mode auto high medium l...
On/off mode fan swing sleep super smart ifeel dimmer timer on timer off clock on on off off on on off off 5 airflow direction control vertical airflow is automatically adjusted to a certain angle in accordance with the operation mode after turning on the unit. The direction of airflow can be also ad...
Indoor temperature smart button is ineffective in super mode. Target temperature 21 ℃ or below 22 ℃ 22 ℃ 26 ℃ over 26 ℃ 21 ℃-23℃ 23 ℃-26℃ your feeling what you can do in smart mode button adjustment procedure operation mode heating fan only dry room temperature decrease 1.5 ℃ after operate for 3 min...
Timer mode how to set timer on how to cancel timer on timer on button can be used to set the timer programming as wished in order to switch on the appliance at your desired time. Press timer on button, "on 12:00" flashes on the lcd, then you can press the or buttons to select your desired time for a...
28 operation instructions sleep mode super mode sleep mode can be set in cooling, heating,drying operation mode. This function gives you a more comfortable environment for sleep. The appliance will stop operation automatically after operating for 8 hours. In sleep mode, note: heating is not availabl...
Turn off the appliance first before disconnecting from power supply. It is necessary to clean the air filter after using it for about 200 hours. Clean it as follows: front panel maintenance air filter maintenance cut off the power supply never use volatile substance such as gasoline or polishing pow...
Noise pollution operating condition the protective device maybe trip and stop the appliance in the cases listed below. Heating cooling dry o room temperature is over 27 c o room temperature is below 21 c o room temperature is below 18 c if all operation has stopped, press on/offbutton again to resta...
Trouble analysis does not run no cooling or heating air ineffective control does not operate immediately peculiar odor a sound of flowing water cracking sound is heard spray mist from the outlet the running indicator flashes on constantly, and indoor fan stops. For the reason that all indoor units u...
Over 50mm over 50mm over 50mm over 2500mm i o r u i nd o n t a installation diagram installation must be performed in accordance with the national wiring standards by authorized personnel only. Above figure is only a simple presentation of the unit, it may not match the external appearance of the un...
Location for installing indoor unit: 1. No obstacle near the air outlet and the cooling air can 2. It is easy to draw off connection pipe and drill a wall hole 3. Keep the required distance from the ceiling and wall 4. Easy to detach air filter. 5. Keep the appliance and remote controller a distance...
Pipe direction 1 2 3 4 trough note: when installing the pipe at the directions 1,2 or 4, saw the corresponding unloading piece off the indoor unit base. Unloading piece saw the unloading piece off along the trough put the pipes (liquid and gas pipe) and cables through the wall hole from outside or p...
Installation instructions pipe joints thermal insulation: wrap the pipes joints with thermal insulation materials and then wrap with a vinyl tape. Pipes thermal insulation: a. Place the drain hose under the pipes. B. Insulation material uses polythene foam over 6mm in thickness. Note: drain hose is ...
4. Connecting of the cable indoor unit connect the connecting cable to the outdoor unit by connecting the wires to the terminals on the control board individually in accordance with the outdoor unit connection. Chassis cabinet front panel cable specifications note: for some models, it is necessary t...
Please read this manual before installing and using it. Only the air conditioner can be connected to the power line. Refer to the rating plate of the equipment for power consumption details. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or similarly qual...
Service.Clima@hisenseitalia.It hisense italy srl via sestriere, 5 – 10060 candiolo (to), italy tel. +39 011 500916 fax +39 011 5183200 e-mail: service.Clima@hisenseitalia.It - www.Hisenseitalia.It c.F. - p.Iva 09403050017.