Kelvinator KSD25HRG Installation Manual

Other manuals for KSD25HRG: User Manual
Manual is about: Inverter Air Conditioner

Summary of KSD25HRG

  • Page 1

    Inverter air conditioner installation manual ksv25crg, ksv35crg, ksv70crg, ksv25hrg, ksd25hrg, ksv35hrg, ksd35hrg, ksv50hrg, ksd50hrg, ksv70hrg, ksd70hrg, ksv80hrg, ksd80hrg.

  • Page 2

    Congratulations and thank you for choosing our inverter split system room air conditioner. We are sure you will find your new air conditioner a pleasure to use. Before you use the air conditioner, we recommend that you read through the entire user manual, which provides the description of the air co...

  • Page 3

    Kelvinator air conditioning important safety instructions 3 warning caution 1 the unit must only be installed by a qualified refrigeration mechanic and electrical work carried out by a qualified electrician according to as/nzs 3000 electrical installation standard and in accordance with all local an...

  • Page 4

    4 choosing a location kelvinator air conditioning choosing a location to mount unit indoor unit • do not install the unit near any heat source, flammable gas or steam. • choose a location where the air circulation is good, and where there are no obsticles blocking the air flow. • select a place that...

  • Page 5

    Kelvinator air conditioning installation drawing 5 installation drawing note: appearance of outdoor unit and indoor unit may differ from some models. The actual shape shall prevail. Air conditioner qty. Qty. 1 indoor unit 1 7 battery (aaa 1.5v) 2 2 outdoor unit 1 8 drain elbow & seal 1 3 indoor unit...

  • Page 6

    6 indoor unit installation kelvinator air conditioning indoor unit installation remove the installation plate from the indoor unit. The installation plate should be installed on a wall which can support the weight of the indoor unit. Model indoor unit dimensions w x h x d (mm) weight (kg) ksv25crg k...

  • Page 7

    Kelvinator air conditioning indoor unit installation 7 indoor unit installation drilling the wall 1. Choose the hole position to be either on the left or right side of the installation plate and mark the position according to the dimensions shown in figure 2. Note most simple installation is with ho...

  • Page 8

    8 indoor unit installation kelvinator air conditioning indoor unit installation drain piping 1. Run the drain hose as shown in figure 6, ensuring it has a constant downward fall. 2. The installer must supply a suitable drain hose extension to run from the indoor unit drain hose to the desired drain ...

  • Page 9

    Kelvinator air conditioning indoor unit installation 9 indoor unit installation recommended circuit breaker rating model circut breaker rating (amps) ksv25crg, ksv25hrg, ksd25hrg 15a ksv35crg, ksv35hrg, ksd35hrg 15a ksv50hrg, ksd50hrg 20a ksv70crg, ksv70hrg, ksd70hrg 25a ksv80hrg, ksd80hrg 25a note:...

  • Page 10

    Outdoor unit installation warning caution • install the outdoor unit on a rigid base to prevent excessive noise level and vibration. • choose an outdoor unit location where the air outlet direction is not blocked, and the clearances as per the assembly diagram (figure 1) are followed. • in the case ...

  • Page 11

    Kelvinator air conditioning outdoor unit installation 11 outdoor unit installation refrigerant pipe connection note: • the connectors used to join the indoor and outdoor refrigeration pipes must be located outside. They cannot be located inside or within a wall cavity where refrigerant may build up ...

  • Page 12

    12 outdoor unit installation kelvinator air conditioning flaring work tips & information important for installer it is critical that the installer follows the correct flaring procedure using the right tools to produce good quality flares in order to ensure installation without refrigerant gas leaks....

  • Page 13

    Kelvinator air conditioning outdoor unit installation 13 outdoor unit installation tightening connection • align the center of the pipes. • sufficiently tighten the flare nut with fingers, and then tighten it with a spanner and torque wrench as shown in fig.16 & 17. Outer diameter (mm) torque (n.Cm)...

  • Page 14

    14 outdoor unit installation kelvinator air conditioning electrical connection wiring diagram 1(l) 1(l) 2(n) 2(n) s s l n indoor unit terminal block (3) power supply outdoor unit terminal block key: 1(l) = live (brown) 2(n) = neutral (blue) s = signal (white) = earth (yellow & green) installation of...

  • Page 15

    Kelvinator air conditioning test running 15 test running air purging air and other foreign matter in the refrigerant circuit causes abnormal pressure rise, which may result in equipment damage and even injury. Therefore, the indoor unit and tubing between the indoor and outdoor unit must be leak tes...

  • Page 16

    16 outdoor unit installation kelvinator air conditioning outdoor unit installation • make sure the refrigerant added into the air conditioner is liquid form. Caution in handling the packed valve • to open the packed valve, remove the cap then open the valve stem using an allen key until it hits the ...

  • Page 17

    Kelvinator air conditioning electrical and gas leak check 17 electrical and gas leak check electrical safety check perform the electric safe check after completing installation: 1. Earth connection - check the earth connection visually and with a multi meter following national wiring rules to confir...

  • Page 18

    18 information servicing kelvinator air conditioning information servicing checks to the area prior to beginning work on systems containing flammable refrigerants, safety checks are necessary to ensure that the risk of ignition is minimised. For repair to the refrigerating system, the following prec...

  • Page 19

    Kelvinator air conditioning information servicing 19 information servicing repairs to sealed components 1. During repairs to sealed components, all electrical supplies shall be disconnected from the equipment being worked upon prior to any removal of sealed covers, etc. If it is absolutely necessary...

  • Page 20

    20 information servicing kelvinator air conditioning information servicing charging procedures in addition to conventional charging procedures, the following requirements shall be followed: • ensure that contamination of different refrigerants does not occur when using charging equipment. Hoses or l...

  • Page 21

    Kelvinator air conditioning notes 21 notes.

  • Page 22

    22 notes kelvinator air conditioning notes.

  • Page 23

    Kelvinator air conditioning warranty 23 this document sets out the terms and conditions of the product warranties for electrolux appliances. It is an important document. Please keep it with your proof of purchase documents in a safe place for future reference should you require service for your appl...

  • Page 24

    ©2018 electrolux home products pty ltd abn 51 004 762 341 kman_air_im_jan18 if you’d like further information about kelvinator appliances, please visit your retailer, phone or email our customer care team or visit our website. Telephone: 1300 363 640 fax: 1800 350 067 email: customercare@electrolux....