Kelvinator KSD25HRG User Manual

Other manuals for KSD25HRG: Installation Manual
Manual is about: Inverter Air Conditioner

Summary of KSD25HRG

  • Page 1

    Inverter air conditioner user manual ksv25crg, ksv35crg, ksv70crg, ksv25hrg, ksd25hrg, ksv35hrg, ksd35hrg, ksv50hrg, ksd50hrg, ksv70hrg, ksd70hrg, ksv80hrg, ksd80hrg.

  • Page 2

    2 contents congratulations and thank you for choosing our inverter split system room air conditioner. We are sure you will find your new air conditioner a pleasure to use. Before you use the air conditioner, we recommend that you read through the entire user manual, which provides the description of...

  • Page 3

    3 safety instructions meanings of symbols used in this manual are shown below: warning warning this symbol indicates information concerning your personal safety or information on how to avoid damaging the air conditioner tips & information important this symbol indicates tips and information about u...

  • Page 4

    4 important safety instructions troubleshooting you'll find many answers to common problems in the chart of troubleshooting tips on page 21. If you review the chart of troubleshooting tips first, you may not need to call for service. Service for repair and maintenance, contact your authorised servic...

  • Page 5

    5 installation drawing installation drawing air conditioner qty. Qty. 1 indoor unit 1 7 battery (aaa 1.5v) 2 2 outdoor unit 1 8 drain elbow & seal 1 3 indoor unit mounting plate 1 9 flare nuts 2 4 mounting plate fixing screws, st3.9x25 5 10 installation manual 1 5 remote controller 1 11 user manual ...

  • Page 6

    6 remote control specifications mod e swin g tem p sho rtcu t fa n spee d tim er o ff re set lo ck l ed foll ow m e time r on t urb o self cle an dire ct slee p fres h location of the remote controller • use the remote controller within a distance of 8 meters from the appliance, pointing it towards ...

  • Page 7

    7 using the remote control replacing batteries the following cases signify exhausted batteries. Replace old batteries with new ones. • receiving beep is not emitted when a signal is transmitted. • indicator fades away. The remote controller is powered by two dry batteries (2x aaa 1.5v)housed in the ...

  • Page 8

    8 operation of buttons operation of buttons 1. On/off button this button turns the air conditioner on and off. 2. Mode button press this button to modify the air conditioner mode in a sequence of following: auto > cool > dry > heat > fan note: please do not select heat mode if the machine you purcha...

  • Page 9

    9 operation of buttons operation of buttons 9. Timer on button press this button to initiate the auto-on time sequence. Each press will increase the auto-timed setting in 30 minute increments. When the setting time displays 10.0, each press will increase the auto timed setting by 60 minute increment...

  • Page 10

    10 indicators on lcd indicators on lcd mode display auto cool dry heat fan icon function displayed when data transmitted displayed when remote controller is on battery display (low battery detection) on displayed when timer on time is set off displayed when timer off time is set show set temperature...

  • Page 11

    11 how to use the buttons how to use the buttons on/off mode fan temp sleep swing direct led follow me turbo self clean timer off timer on silence fp auto operation ensure the unit is plugged in and power is available. The operation indicator on the display panel of the indoor unit starts flashing. ...

  • Page 12

    12 timer operation timer operation on/off mode fan temp sleep swing direct led follow me turbo self clean timer off timer on silence fp press the timer on button can set the auto-on time of the unit. Press the timer off button can set the auto-off time of the unit. To set the auto-on time 1. Press t...

  • Page 13

    13 timer operation examples of timer operation timer on (auto-on operation) off start set 6 hours later the timer on feature is useful when you want the unit to turn on automatically before you return home. The air conditioner will automatically start operating at the set time. Example to start the ...

  • Page 14

    14 special functions sleep operation sleep operation cooling heating sleep operation continuous run continuous run 1 hour 1 hour 1°c 1°c 1°c 1°c 1 hour 1 hour set temp. Set temp. When selected, the set temperature will increase (cooling) or decrease (heating) by 1°c per hour for the first 2 hours. U...

  • Page 15

    Warning caution • do not operate the air conditioner for long periods with the air flow direction set downward in cooling or dehumidifying mode. Otherwise, condensation may occur on the surface of the horizontal louver causing moisture to drop on to the floor or on furnishings. • after a quick resta...

  • Page 16

    Manual operation warning caution • this switch is used for testing purposes only. Please do not use it unless necessary. • to restore the remote controller operation, use the remote controller directly. This air conditioner is equipped with a manual switch to allow operation should the remote contro...

  • Page 17

    Before maintenance • turn the system off before cleaning. To clean, wipe with a soft, dry cloth. Do not use bleach or abrasives. Note: power supply must be disconnected before attempting to clean or service. Warning warning servicing shall only be performed as recommended by the equipment manufactur...

  • Page 18

    5. After the filters are dry, refit the small filters onto the large air filter. 6. Re-insert the filters back into the unit following the reverse order as described in steps 1 & 2. 7. Close the front panel. Make sure the buckles are fully fit and the panel is completely closed. Preparation for exte...

  • Page 19

    Troubleshooting symptom cause operation is delayed after restart to prevent blowout of the fuse, the compressor will not operate while the protection circuit is working for about 3 minutes after sudden off/on operation of the power supply, this is normal operation and designed to protect the compres...

  • Page 20

    Troubleshooting symptom diagnostic unit will not operate is there a power failure? Has a switch been turned off, a circuit breaker tripped or a fuse blown? Is the timer operating? Are the batteries used in the remote controller exhausted? Are the batteries used in the remote controller loaded proper...

  • Page 21

    Notes 21 notes.

  • Page 22

    Notes 22 notes.

  • Page 23

    23 warranty warranty for sales in australia and new zealand appliance: kelvinator split system air conditioner important notice before calling for service, please ensure that the steps listed in clause 8 above have been followed. For service or to find the address of your nearest authorised service ...

  • Page 24

    Part no. 66129913264 © 2017 electrolux home products pty ltd. Abn 51 004 762 341 kman_aircare_jun17 australia phone: 1300 363 640 fax: 1800 350 067 email: customercare@electrolux.Com.Au web: kelvinator.Com.Au new zealand phone: 0800 436 245 fax: 0800 225 088 email: customercare@electrolux.Co.Nz web:...