Kelvinator KSE26CRB Installation Manual

Other manuals for KSE26CRB: User Manual

Summary of KSE26CRB

  • Page 1

    Fixed speed split-type room air conditioner installation manual kse26crb, kse26hrb, kse35crb, kse35hrb,kse53hrb, kse62hrb, kse70crb,kse70hrb, kse88crb and kse88hrb refrigerant r410a.

  • Page 2

    Warning do not install yourself. Incorrect installation could cause injury due to fire, electrical shock, the unit falling or leakage of water. Consult the dealer from whom you purchased the unit or authorised installer. Perform the installation securely referring to the installation instruction. In...

  • Page 3

    Kelvinator air conditioning typical installation 5 4 before installation kelvinator air conditioning caution • use a stud finder to locate studs to prevent unnecessary damage to the wall. • a minimum pipe run of 3 metres is required to minimise vibration & excessive noise. • two of the a, b and c di...

  • Page 4

    • ensure that the clearance around the back of the unit is more than 30cm and left side is more than 30cm. The front of the unit should have more than 2.0m of clearance and the connection side (right side) should have more than 60cm of clearance. • do not place animals and plants in the path of the ...

  • Page 5

    Kelvinator air conditioning flaring work and connection 9 8 installation kelvinator air conditioning flaring work and connection of piping installation indoor outdoor 5 -7 m m wall (7.0kw) and (8.0kw) model) a 40 b right rear side refrigerant pipe hole 65 installation plate indoor unit outline left ...

  • Page 6

    Kelvinator air conditioning flaring work and connection 11 10 flaring work and connection kelvinator air conditioning c tape the drain hose and the connecting cable. Be sure that the drain hose is located at the lowest side of the bundle. Locating at the upper side can cause drain pan to overflow in...

  • Page 7

    Kelvinator air conditioning flaring work and connection 13 12 flaring work and connection kelvinator air conditioning • do not connect two power cords together to supply power to the air conditioner. • do not extend the power cable conductors by cutting. • power supply should be in the range of 90%~...

  • Page 8

    Kelvinator air conditioning flaring work and connection 15 14 flaring work and connection kelvinator air conditioning c drain piping • the drain hose should point downward for easy drain flow. • do not make drain piping similar to diagrams shown below. Air tip of drain hose dipped in water less than...

  • Page 9

    Kelvinator air conditioning air purging 17 16 air purging kelvinator air conditioning pressure manifold set outdoor unit indoor unit gauge vacuum pump open close lo hi note: a lo stop valve b hi stop valve c and d: connections to the indoor unit. Charge hose lo hi c evacuation • connect the charge h...

  • Page 10

    Kelvinator air conditioning test running 19 18 test running kelvinator air conditioning indoor unit check point d b c a outdoor unit check point co ver man ua l c ontrol button auto/cool caution a: lo packed valve b: hi packed valve c and d are ends of indoor unit connection. Test running perform te...

  • Page 11

    Notes kelvinator air care notes 21 20 notes kelvinator air care notes.

  • Page 12

    Notes 22 notes kelvinator air care kelvinator air conditioning warranty 23 this document sets out the terms and conditions of the product warranties for electrolux appliances. It is an important document. Please keep it with your proof of purchase documents in a safe place for future reference shoul...

  • Page 13

    P/no. 1452635 © 2011 electrolux home products pty ltd abn 51 004 762 341 print code: kfiximum_jul11 if you’d like further information about kelvinator appliances, please visit your retailer, phone or email our customer care team or visit our website. Telephone: 1300 363 640 fax: 1800 350 067 email: ...