Kelvinator Air Conditioning typical installation 5
4 before installation Kelvinator Air Conditioning
caution
• Use a stud finder to locate studs to prevent
unnecessary damage to the wall.
• A minimum pipe run of 3 metres is required to
minimise vibration & excessive noise.
• Two of the A, B and C directions should be free
from obstructions.
• This illustration is for explanation purposes only.
• Copper lines must be insulated independently.
Pipes needed for installation (Purchase separately according
the following table).
Diameter
6.35mm
9.53mm
12.7mm
16.0mm
19.0mm
1.5kW
Yes
Yes
No
No
No
2.6kW
Yes
Yes
No
No
No
3.5kW
Yes
No
Yes
No
No
5.3kW
Yes
No
Yes
No
No
6.2kW
No
Yes
No
Yes
No
7.0kW
No
Yes
No
Yes
No
8.8kW
No
Yes
No
No
Yes
Yes: Pipe needed on model. No: Pipe not needed on model.
Settlement of outdoor unit
• Anchor the outdoor unit with a bolt and nut (
φ
10mm)
tightly and horizontally on a concrete or rigid mount.
• When installing on a wall, roof or rooftop, anchor the
mounting base securely.
• In case the vibration of the unit is conveyed to the
connecting pipes, secure the unit with an anti-
vibration mount.
Connection pipe
Before Installation
Typical installation
Tools needed for installation
Level gauge
Screwdriver
Electric drill, Hole core drill (
φ
65mm)
Flaring tool set (R410A specific)
Specified torque wrenches: 1.8kgf.m,
4.2kgf.m, 5.5kgf.m, 6.6kgf.m
(different depending on model No.)
Spanner (half union)
Hexagonal wrench (4mm)
Gas-leak detector
Vacuum pump
Gauge manifold
Users manual
Thermometer
Multimeter
Pipe cutter
Measuring tape
Items required for installing the unit
Number Name of Accessories
Qty
1
Installation Plate
1
2
Clip Anchor
8
3
Self-tapping Screw A
8
4
Seal (See page 8 for details)
1
5
Drain Joint (See page 8 for details)
1
6
Remote controller
1
Note: Excluding the parts that are provided with the
unit detailed above all other parts must be
purchased separately.
Loop the
connective
cable.
Air Outlet
15cm clearance
2
1
3
6
7
2.0m below
60cm above
Air Filter
30cm left
12cm right
30cm behind
60cm right
2.0m front
A
B
C