  • Page 1

    Inverter split room air conditioner installation manual ksv25hrd, ksv35hrd, ksv52hrd, ksv70hrd, ksv80hrd refrigerant r410a.

  • Page 2

    2 contents congratulations and thank you for choosing our inverter speed split room air conditioner. We are sure you will find your new air conditioner a pleasure to use. Before you use the air conditioner, we recommend that you read through the entire user manual, which provides the description of ...

  • Page 3

    3 safety warning caution 1 the unit must only be installed by a qualified refrigeration mechanic and electrical work carried out by a qualified electrician according to as/nzs3000 electrical installation standard and all local and national regulations, and in compliance with this manual. 2 before in...

  • Page 4

    4 notice for installation safety precautions for electric appliances 1. A dedicated power supply circuit should be used for products not supplied with a service cord and plug in accordance with local electrical safety regulations. 2. The unit must be reliably earthed and connected to a rcd by the qu...

  • Page 5

    5 installation drawing installation drawing space to the ceiling space to the wall space to the wall air outlet side space to the floor horizontally in front below 15cm horizontally to the side 15cm horizontally to the side 300cm 200 cm 15cm above the dimensions of the minimum clearance if these dim...

  • Page 6

    6 installation instructions 2. Insert the piping-hole sleeve into the hole to prevent the connection piping and wiring from being damaged when passing through the hole. Ø Ø 55/ 65 indoor outdoor wall pipe seal pad installation of drain hose 1. Connect the drain hose to the outlet pipe of the indoor ...

  • Page 7

    7 installation instructions installation of indoor and outdoor electric wires 1. Open the front panel. 2. Remove the wiring cover connect and fix the power connection cord to the terminal board as shown in below. 3. Pass the power connection cord through the hole at the back of the indoor unit. 4. R...

  • Page 8

    8 installation instructions 1 flaring work main cause for refrigerant leakage is due to defects in the flaring work. Carry out correct flaring work using the following procedure: oblique 90 c roughness burr a: cut the pipes and the cable. 1. Use the piping kit accessory (if applicable) or pipes purc...

  • Page 9

    9 installation instructions tightening connection • align the center of the pipes. • sufficiently tighten the flare nut with fingers, and then tighten it with a spanner and torque wrench as shown below. Spanner torque wrench piping taper nut indoor unit piping model discharge (mm) suction (mm) maxim...

  • Page 10

    10 installation instructions installation and maintenance of hepa filter check after installation and operation test check after installation items to be checked possible malfunction has the unit been fixed firmly? The unit may drop, shake or emit noise. Has you the refrigerant leakage test been don...

  • Page 11

    11 dred network cable installation installation of dred network cable installation instruction of dred network cable insert network cable tightly as shown in the fig. For 2.5kw and 3.5kw is as below: clasp of rj45 plug of network cable shall aim at the notch of rj45 terminal to be installed. The cla...

  • Page 12

    12 notes notes.

  • Page 13

    13 notes notes.

  • Page 14

    14 notes notes.

  • Page 15

    15 warranty this document sets out the terms and conditions of the product warranties for electrolux appliances. It is an important document. Please keep it with your proof of purchase documents in a safe place for future reference should you require service for your appliance. 1. In this warranty: ...

  • Page 16

    Part no. 66129909124 © 2015 electrolux home products pty ltd. Abn 51 004 762 341 kman_airwave_im_jun15 australia phone: 1300 363 640 fax: 1800 350 067 email: customercare@electrolux.Com.Au web: kelvinator.Com.Au new zealand phone: 0800 436 245 fax: 0800 225 088 email: customercare@electrolux.Co.Nz w...