Kelvinator KSV26CRE Installation Manual

Other manuals for KSV26CRE: User Manual
Manual is about: Inverter Room

Summary of KSV26CRE

  • Page 1

    Inverter room air conditioner installation manual ksv26cre, ksv26hre, ksv35cre, ksv35hre, ksv53hre, ksv62hre, ksv70cre, ksv70hre, ksv80hre refrigerant r32.

  • Page 2

    Congratulations and thank you for choosing our inverter air conditioner. We are sure you will find your new air conditioner a pleasure to use. Before you use the air conditioner, we recommend that you read through the entire user manual, which provides the description of the air conditioner and its ...

  • Page 3

    Kelvinator air conditioning important safety instructions 3 caution 1 the unit must only be installed by a qualified refrigeration mechanic and electrical work carried out by a qualified electrician according to local or government regulations and in compliance with this manual. 2 before installatio...

  • Page 4

    4 installation instructions kelvinator air conditioning minimum floor areas your air conditioner is designed to condition the air for a certain range of room sizes, please ensure the selection of your air conditioner complies with the kelvinator selection tool available from www.Kelvinator.Com.Au th...

  • Page 5

    Kelvinator air conditioning installation drawing 5 product description light turbo healthy timer-on temp timer-off swing i feel eco fan clock mode 2 3 indoor unit outdoor unit space to obstruction air inlet side space to the wall space to the wall space to the ceiling space to the floor air outlet s...

  • Page 6

    6 checklist kelvinator air conditioning important • if your appliance is damaged due to improper installation your warranty may be void. • proper installation requires the use of a licensed installer. • you must keep full details of the installer including the license number and provide those detail...

  • Page 7

    Kelvinator air conditioning installation instructions 7 15 note low temperature soldering alloys are not acceptable. 16 minimum room space requirements as advised on the rating plate must be complied with. 17 reusable mechanical connectors may not be used within indoors or within wall or ceiling cav...

  • Page 8

    8 installation instructions kelvinator air conditioning rooftop installation if the outdoor unit is installed on a roof structure, be sure to level the unit. Ensure the roof structure and anchoring method are adequate for the unit location. If the outdoor unit is installed on roof structures or exte...

  • Page 9

    Kelvinator air conditioning installation instructions 9 outdoor unit installation outdoor condensate drainage • during heating operation, the condensate and defrosting water should be drained out reliably through the drain hose. • the drain-water hole must be plugged. Whether to plug other holes wil...

  • Page 10

    10 installation instructions kelvinator air conditioning indoor unit installation installing the mounting plate 1 fit the mounting plate horizontally on the wall with five or more self-tapping screws (type st4x25, item 3 on page 3). 2 be sure that the mounting plate has been fixed firmly enough to w...

  • Page 11

    Kelvinator air conditioning installation instructions 11 mounting plate type c mounting plate type d indoor unit installation 70 70 36 67 67 36 14 6 90 65 575 left right indoor unit indoor unit 172 253 179 746 1073 183 685 14 9 326 33 7 65 65 50 163 90 6 74 105.

  • Page 12

    12 installation instructions kelvinator air conditioning indoor unit installation drill piping hole 1. Determine hole positions according to the diagram. Drill one (1) hole ( Ф 55 or Ф 70 mm) in the wall at a slight downward slant to the outdoor side. Piping hole model 55 ksv26cre, ksv35cre, ksv26hr...

  • Page 13

    Kelvinator air conditioning installation instructions 13 caution 1. The insulating tube should be connected reliably with the sleeve outside the outlet pipe. 2. The drain hose should be slanted downward slightly, without distortion, bulge or fluctuation. Do not block water flow with a rise do not pu...

  • Page 14

    14 installation instructions kelvinator air conditioning d. Insert the drain hose into the drain hole at the rear right of the indoor unit. Drain hose 3. Arrange the pipe in the most convenient direction and position. Piping on the rear right side drain hose from the left side piping on the rear rig...

  • Page 15

    Kelvinator air conditioning installation instructions 15 4. Take out the piping from body case, wrap the piping, power cords, drain hose with the tape and then make them pass through the piping hose. Do not put any object in the drain pan located in the rear of the indoor unit, as the condensed wate...

  • Page 16

    16 installation instructions kelvinator air conditioning refrigerant pipe connection the main cause of refrigerant leakage is due to defects in the flaring work. Carry out flaring work using the following procedure: note: when using refrigerant r32, a reusable flared connection is the only allowed p...

  • Page 17

    Piping connection - indoor unit a. Connecting the indoor unit tubing to the connection piping: align the centres of the pipes and sufficiently tighten the flare nut with your hands first. Indoor unit tubing flare nut piping torque wrench spanner (fixed) flare nut piping indoor unit piping then tight...

  • Page 18

    C. Positioning the indoor unit: remove the spacer. Hook the indoor unit onto the upper portion of the mounting plate (engage the hooks of the mounting plate into the openings at the rear top of the indoor unit). Ensure that the hooks are properly seated on the mounting plate by moving the indoor uni...

  • Page 19

    Indoor unit installation safety precautions kelvinator air conditioning safety precautions 19 c. In cases where the outdoor unit is installed above the indoor unit level: wrap the piping and connecting cable from bottom to top. Form a trap to prevent water from entering the room. Secure the wrapped ...

  • Page 20

    Indoor electric wiring note: for correct operation of the air conditioner and standby power modes the mains power should be supplied to the indoor unit. 1. Open the front panel and remove the wiring cover by loosening the screw. Wiring cover n(1) 2 4 5 n(1) 2 3 n(1) 2 2. Route the power connection c...

  • Page 21

    Outdoor electric wires 1. When required, remove the handle on the right side plate of outdoor unit by loosening the screw. Handle terminal block n(1) 2 n(1) 2 3 n(1) 2 4 5 2. Take off wire cable clamp. Connect and screw the power connection cable and signal control wire (for reverse cycle models onl...

  • Page 22

    Checking the drainage a. Open and lift the indoor unit front panel. Hold the lower part of the left and right sides of the panel, pull it against you and lift it stops with a full support from the bracket. Panel bracket b. Check the drainage carefully pour a glass of water on the evaporator. Ensure ...

  • Page 23

    Outdoor unit indoor unit gas side liquid side half union hi stop valve (2-way valve) caution a: low pressure valve (3-way) - gas side. B: high pressure valve (2-way) - liquid side. C and d: they are the ends of indoor unit connection valve body flare nut cap charge port valve stem stopper make sure ...

  • Page 24

    24 kelvinator air conditioning installation instructions testing the air conditioner soapy water method apply soapy water or liquid neutral detergent on all valves and pipe connections (a, b, c and d, refer to the figure below) involved in installation by a soft brush to check for leakage. If bubble...

  • Page 25

    Kelvinator air conditioning installation instructions 25 post installation checks items to be checked possible malfunction has the unit been fixed firmly? The unit may drop, shake or emit noise have you done the refrigerant leakage test? It may cause insufficient cooling (heating) is thermal insulat...

  • Page 26

    26 notes kelvinator air conditioning notes.

  • Page 27

    Kelvinator air conditioning warranty 27 this document sets out the terms and conditions of the product warranties for electrolux appliances. It is an important document. Please keep it with your proof of purchase documents in a safe place for future reference should you require service for your appl...

  • Page 28

    © 2013 electrolux home products pty ltd abn 51 004 762 341 kman_kairinv2_im_dec13 if you’d like further information about kelvinator appliances, please visit your retailer, phone or email our customer care team or visit our website. Telephone: 1300 363 640 fax: 1800 350 067 email: customercare@elect...