    Installation instructions horizon 3 sided fireplaces.

  • Page 2

    Installation instructions kemlan natural draft electronic ignition 3 sided gas fireplaces 2 model type 2: natural draft electronic ignition gas fireplace data plate: refer to data plate for information in respect to gas pressure, consumption and gas type,natural or lpg. Data plate is located under t...

  • Page 3

    3 installation instructions kemlan natural draft electronic ignition 3 sided gas fireplaces installation 1. The n.D.E.I. System is supplied with all required electrical fittings. Work needs to be undertaken by a licensed electrician if extending wiring. Wiring requires clearance of minimum 100mm to ...

  • Page 4

    4 installation instructions kemlan natural draft electronic ignition 3 sided gas fireplaces measurements and specification of ndei three sided 150mm +-285mm 150mm min 80mm 108mm 60mm cement sheeting under 1000mm min 150mm b e c g d f note: 1. Glass on one side is optional all structural work to arch...

  • Page 5

    5 installation instructions kemlan natural draft electronic ignition 3 sided gas fireplaces ventilation required under. Min 10 fc sheet. Minimum 4x 50mm holes in sheet between framing. Sections frame details a f b c e refer frame details clearance to flue min 25mm vented under 10mm sheeting min 80mm...

  • Page 6

    6 installation instructions kemlan natural draft electronic ignition 3 sided gas fireplaces power flue internal kit all structural work to architects design internal power flue components : 1. 1x reducer - stainless steel - size as above - 150mm 2. 1x attenuator - zincanneal 3. 1x power flue fan - i...

  • Page 7

    7 installation instructions kemlan natural draft electronic ignition 3 sided gas fireplaces power flue external kit all structural work to architects design external power flue components : 1. 1x reducer - stainless steel - size as above - 150mm 2. 1x attenuator - zincanneal 3. 1x flues - stainless ...

  • Page 8

    8 installation instructions kemlan natural draft electronic ignition 3 sided gas fireplaces location requirements all structural work to architects design space heaters up to 50 mj/h input up to 50 mj/h input over 50 mj/h & up to 50 mj/h over 150 mj/h input all other devices clearances ā€˜nā€™ (mm) note...

  • Page 9

    9 installation instructions kemlan natural draft electronic ignition 3 sided gas fireplaces gas installation 1. Check unit is suitable for intended gas supply. 2. Note position on gas appliance on drawing specification on right hand side of appliance. 3. Gas cock has to be fitted prior to gas burner...

  • Page 10

    10 installation instructions kemlan natural draft electronic ignition 3 sided gas fireplaces laying the fire - coal & pebble mark 2 coals 440 / 500 - 390 x 240 mark 2 coals 600 - 460 x 260 mark 2 coals 700 - 580 x 260 mark 2 pebbles 700 - 580 x 260 mark 2 coals 700/800 - 600 x 155 mark 2 pebbles 700...

  • Page 11

    11 installation instructions kemlan natural draft electronic ignition 3 sided gas fireplaces commissioning procedure installed correctly the burner should not emit any fumes into the room. The following procedure should be undertaken to test that the unit is operating correctly. 1. After unit has be...

  • Page 12

    12 wiring diagram for further service information contact kemlan australia head office: 13 french avenue, brendale qld 4500 ph: (07) 3490 5500 fax: (07) 3490 5520 www.Kemlan.Com sense electrode model n a flue fan air flow switch air flow switch wall switch 1 2 n2 e a n e j4 j3 j1 j2 3 5 4 6 pvc encl...

  • Page 13

    13 wiring diagram for further service information contact kemlan australia head office: 13 french avenue, brendale qld 4500 ph: (07) 3490 5500 fax: (07) 3490 5520 www.Kemlan.Com 430x125mm air vent to air burner wall switch on/off switch burner 240v plug 3 sided elevation.

  • Page 14

    14 wiring diagram for further service information contact kemlan australia head office: 13 french avenue, brendale qld 4500 ph: (07) 3490 5500 fax: (07) 3490 5520 www.Kemlan.Com head office 13 french avenue, brendale qld 4500 ph: (07) 3490 5500 fax: (07) 3490 5520 www.Kemlan.Com.