Installation Instructions Kemlan Natural Draft Electronic Ignition 3 Sided Gas Fireplaces
2
Model Type 2:
Natural Draft Electronic
Ignition Gas Fireplace
DATA PLATE: Refer to data plate for information
in respect to gas pressure, consumption and gas
type,Natural or LPG.
Data Plate is located under the gas burner and is
accessed by lifting front access panel or removing
base plate.
Location Requirements
Horizon natural draft electronic ignition fireplaces are
designed to be installed as a complete fireplace system.
The firebox incorporates a gas burner with electronic
ignition and spiggot for attaching a flue. The flue needs
to run vertically and exit above the roof line. 45 degree
bends can be utilised. All A.G.A requirements for flues
are to be observed when installing.
Natural Draft Electronic
Ignition approved for the
following models:
SUITABLE GAS BURNER OPTION
THREE SIDED MODELS
1100 Low Line
1500 Low Line
1100 Coal
1100 Pebble
1500 Coal
1500 Pebble
Ventilation Requirements:
Rooms with gas open fires require fresh air vents a per
gas regulations. For example:
1 x VENT REQUIRED
2 x VENTS REQUIRED
VENTILATION: An opening to outside with a minimum
free ventilation area of 400sq centimetres for each
decorative gas log fire.
NOTE: The chimney in which the appliance is installed
is not to be considered as a ventilation opening
430mm
125mm
270mm
125mm