Kemppi 3200 Operating Manual

Summary of 3200

  • Page 1

    Operating manual • english käyttöohje • suomi bruksanvisning • svenska bruksanvisning • norsk brugsanvisning • dansk gebrauchsanweisung • deutsch gebruiksaanwijzing • nederlands manuel d’utilisation • français instrukcja obsługi • polski Инструкции по эксплуатации • По-русски en fi sv no da de nl fr...

  • Page 3: Operating Manual

    Operating manual english kempo w eld 3200, 3200w / © kemppi o y / 1117.

  • Page 4

    En contents 1. Preface ................................................................................................................................ 3 1.1 general .........................................................................................................................................

  • Page 5

    En 1. Preface 1.1 general congratulations on choosing the kempoweld power source. Used correctly, kemppi products can significantly increase the productivity of your welding, and provide years of economical service. This operating manual contains important information on the use, maintenance and saf...

  • Page 6

    En 1.3 kempoweld panels 1.3.1 operation control and connectors s1, h1 h2 s2 s3 x1 05 x2 s1 main switch (pilot lamp h1) s2 voltage selecting switch (coarse grading) s3 voltage selecting switch (fine grading) h2 pilot lamp for overheating (power source) x1 return current connector (coarser arc) x2 ret...

  • Page 7

    En f2 fuse for cooling unit (2 a delayed) 02 water circulation return connector 03 water circulation output connector 04 filler hole for water tank 1.3.3 rear plate of kempoweld 3200, 3200w 02 03 01 x3 f1 x4 01 inlet of mains cable f1 fuse of auxiliary transformer (8 a delayed) x3 welding current co...

  • Page 8

    En 1.4.2 accessories kmw sync k3 wire feed adjustment selection (panel or push-pull gun) x1 control connector for push-pull gun 1.4.3 cooling unit connections 01 return water connector for gun 02 feed water connector for gun 04 inlet of water hoses 1.4.4 rear panel x3 x2 03 04 03 shielding gas conne...

  • Page 9

    En 2. Installation 2.1 positioning of the machine place the machine on a firm, dry and level surface. Where possible, do not allow dust or other impurities to enter the machines cooling air flow. Preferably site the machine above floor level; for example on a suitable carriage unit. Notes for positi...

  • Page 10

    En the cable is entered into the machine through the inlet ring on the rear wall of the machine and locked with a cable clamp (05). The phase conductors of the cable are coupled to connectors l1, l2 and l3. The earth protection coloured green-yellow is coupled to connector marked with earth protecti...

  • Page 11

    En 2.5 operation and use of controls see the page for kempoweld panels and cooling unit. 2.5.1 main switch (s1) in zero position all control and welding current circuits of the equipment are dead (without voltage). In position i the control circuits of the machine become live (get voltage). The prim...

  • Page 12

    En 2.5.7 accessory drawer in the accessory drawer in the cover part of the unit are by delivery the plastic guide tubes needed for welding of aluminium and stainless steels. In the drawer are also the screw and the insulation bushings needed for locking of rotation of the wire feeder kempoweld wire ...

  • Page 13

    En note! If the water does not start circulating, see paragraph operation disturbances: “the water does not circulate ... Etc. Do not let any waste and dirt into the water circulation! Check filling volume before starting to weld! Use the cooling liquid according to recommendations, or the one you k...

  • Page 14

    En 3. Operation disturbances by the operation or functional disturbances take the measures according to the following list. If the disturbance cannot be eliminated, check the equipment according to the paragraphs installation and maintenance, and take contact with authorized kemppi repair workshop. ...

  • Page 15

    En 4. Maintenance the amount of use and the working environment should be taken into consideration when planning the frequency of maintenance of the machine. Careful use and preventive maintenance will help to ensure trouble-free operation. Cables check the condition of welding and connection cables...

  • Page 16

    En 5. Ordering numbers units kempoweld 3200 230 v / 400 v 621532002 kempoweld 3200w 230 v / 400 v 621632002 wire feeder unit kempoweld wire 400 621740001 accessories kmw sync 2 6219150 msd-1 6185666 p500 transport unit (feeder) 6185265 kv400 swing arm 6185247 kv400 50-1.5-gh 6260351 kv400 50-1.7-wh ...

  • Page 17

    En air-cooled interconnection cables mounting cables for short distance: kw 50-1.3-gh 6260350 interconnection cables for long distance: multimig 50-5-gh 626010401 multimig 50-10-gh 626010601 liquid-cooled interconnection cables mounting cables for short distance: kw 50-1.5-wh 6260352 interconnection...

  • Page 18

    En 6. Technical data kempoweld 3200 3200w connection voltage 3 ~ 400 v 380 v -10 % ... 415 v +6 % 380 v -10 % ... 415 v +6 % 3 ~ 230 v 220 v -10 % ... 240 v +6 % 220 v -10 % ... 240 v +6 % connection capacity 230 v / 400 v 40 % ed 13,6 kva 13,6 kva 60 % ed 10,0 kva 10,0 kva 100 % ed 6,6 kva 6,6 kva ...

  • Page 19

    En 17 kempo w eld 3200, 3200w / © kemppi o y / 1117.

  • Page 20

    Www.Kemppi.Com 1922010 1117 kemppi oy hennalankatu 39 pl 13 fin-15801 lahti finland tel +358 3 899 11 telefax +358 3 899 428 export@kemppi.Com www.Kemppi.Com kotimaan myynti: tel +358 3 899 11 telefax +358 3 734 8398 myynti.Fi@kemppi.Com kemppi sverige ab box 717 s-194 27 upplands vÄsby sverige tel ...