Kemppi FastMig KM300 Operating Manual - page 13
3.3.10 setting of the Mig operating mode
Button P7 allows you to set the MIG welding gun to either two-sequence or four-sequence
mode. The indicator shows the mode selected.
• In two-sequence mode (2T), welding is started by pressing the gun switch and stopped
by releasing the switch.
• In four-sequence mode (4T), the following actions take place:
1. When you press the gun switch, the shielding gas starts to flow.
2. When you release the switch, welding starts.
3. When you press the switch again, welding ends.
4. When you release the switch again, the flow of the shielding gas ends.
3.3.11 setting of operation parameters
Button P7 also is used for changing welding parameters as follows:
• Depress button P7 for at least five seconds. The set-up menu appears on display P2.
• Select the parameter to adjust with the left-hand knob (P8) so that the name of the
parameter you want to adjust is shown on display P2.
• Set a value for the parameter by using the right-hand knob (P9) such that the value you
want is shown on display P2. The value you selected is recorded in the control panel
memory.
• Exit the set-up menu by pressing button P7 again and holding for at least five seconds or
by briefly pressing the control panel start button (P1).
The table below lists the operation parameters and their possible values.
Name of
parameter
Name
displayed
Parameter
values
Factory
values
Description
Pre gas Time
PrG
0.0…9.9 s
(0.1 s)
Pre-welding gas time in seconds
Post Gas Time
PoG
Aut, 0.1…32.0 s
(Aut)
Post-welding gas time in seconds or
automatically according to welding
current 1 s / 100 A (Aut)
Creep Start Level
CrE
10…170 %
(50 %)
Initial wire feeding speed as a
percentage of the pre-set value:
10% = slowed start
100% = no creep start
170% = rush start
Start power
StA
-9…+9
(0)
Strength of initial pulse
Post Current Time
PoC
-9…+9
(0)
Post-welding current time
Remote Switch
rS
2t4, Inc
(2t4)
Selection of wire feed device switch
operation
Calibration Menu
CAL
– – –, Ent
(– – –)
Wire feed speed calibration (see
instructions in sub-section 3.3.12)
LongSystem Mode
LSy
on, OFF
(OFF)
Select ‘ON’ if you are using long (>40
m) connector cables
Restore Factory
Settings
FAC
OFF, PAn, All
(OFF)
Restore factory settings; exit the
menu by selecting ’All’
EN