Kemppi Minarc 120 AU Operating Manual - Operating Manual

Other manuals for Minarc 120 AU: Operating Manual

Summary of Minarc 120 AU

  • Page 1

    Minarc 150, 151 150 vrd 120 au, 150 au operating manual • english käyttöohje • suomi bruksanvisning • svenska bruksanvisning • norsk brugsanvisning • dansk gebrauchsanweisung • deutsch gebruiksaanwijzing • nederlands manuel d’utilisation • français manual de instrucciones • español instrukcja obsług...

  • Page 3: Operating Manual

    En operating manual english m inar c 150, 151 / © kemppi o y / 1117.

  • Page 4: Contents

    En contents 1. Preface ................................................................................................................. 3 1.1 general .......................................................................................................................... 3 1.2 product introduction...

  • Page 5: Preface

    En 1. Preface 1.1 general congratulations on choosing the minarc equipment. Used correctly, kemppi products can significantly increase the productivity of your welding, and provide years of economical service. This operating manual contains important information on the use, maintenance and safety of...

  • Page 6: 1.2

    En 1.2 product introduction kemppi minarc is a manual metal arc welding machine, small in size, suitable for industry, site and repair welding. The unit uses one phase connection voltage and it is manufactured for two different mains voltages: 230 v (minarc 150) and 110 v (minarc 151). Minarc tolera...

  • Page 7: 2.3

    En 2.3 serial number serial number of the unit is marked on the rating plate of the unit. The serial number makes it possible to trace product manufacturing series. You might need the serial number when placing spare parts orders or when planning maintenance. 2.4 main components connect welding cabl...

  • Page 8: 2.5

    En 2.5 distribution network all regular electrical devices without special circuits generate harmonic currents into distribution network. High rates of harmonic current may cause losses and disturbance to some equipment. Minarc 150, 150 vdr, 120 au, 150 au warning: this equipment does not comply wit...

  • Page 9: Use

    En 3. Use note! It is forbidden to weld in places where there is a danger of fire or explosion! 3.1 welding processes 3.1.1 manual metal arc welding (mma) in manual metal arc (mma) the welding filler material is melted from the electrode to the weld pool. Rate of welding current is selected on the b...

  • Page 10: 3.2

    En 3.2 operating functions see also 2.4. Main components and 3.4. Welding selections. 1. Signal light, machine 'on', (vrd: 'vrd safe on') 2. Welding process selecting switch 3. Welding current adjuster 4. Signal light for overheating 5. Suitable electrodes; reference values for welding current 1 3 2...

  • Page 11: 3.3

    En welding process selector, mma / tig switch is used for selecting either mma or tig welding, depending on welding target. Vrd: when you have switched the unit to tig welding, vrd is constantly active, thus reducing terminal voltage to 30 v. This facilitates arc cut-off when you stop welding. Regul...

  • Page 12: 3.4

    En 3.4 welding selections note! Welding fumes may be dangerous to your health, see that there is ample ventilation during welding! Never look at the arc without face shield made for arc welding! Protect yourself and your surroundings from the arc and hot spatter! 3.4.1 earthing if possible, always f...

  • Page 13: Maintenance

    En 4. Maintenance note! Be careful when handling electrical cables! In maintaining the unit, take into consideration the rate of use and the environment it is used in. When the unit is used properly and serviced regularly, you will avoid unnecessary disturbances in use and production. 4.1 daily main...

  • Page 14: 4.3

    En 4.3 disposal do not dispose of electrical equipment with normal waste! In observance of european directive 2002/96/ec on waste electrical and electronic equipment, and its implementation in accordance with national law, electrical equipment that has reached the end of its life must be collected s...

  • Page 15: Technical Data

    En 6. Technical data minarc 150, 150 vrd minarc 151 connection voltage 1 ~ phase 50/60 hz 230 v ± 15 % 110 v ± 15 % rated power at max. Current 35 % ed mma 140 a/7.5 kva 140 a/7.5 kva 100 % ed mma 100 a/5.1 kva 100 a/5.1 kva 35 % ed tig 150 a/5.0 kva 150 a/5.0 kva 100 % ed tig 110 a/3.3 kva 110 a/3....

  • Page 16

    En minarc 120au minarc 150au connection voltage 1 ~ phase 50/60 hz 240 v + 10 % ... - 20 % 240 v + 10 % ... - 20 % rated power at max. Current ed mma 50 %, 110 a/5.5 kva 35 %, 140 a/7.5 kva ed mma 100 %, 80 a/3.9 kva 100 %, 100 a/5.1 kva ed tig 50 %, 120 a/3.5 kva 35 %, 150 a/5.0 kva ed tig 100 % ,8...

  • Page 17

    En 15 m inar c 150, 151 / © kemppi o y / 1117.

  • Page 18

    Kemppi oy hennalankatu 39 pl 13 fin-15801 lahti finland tel +358 3 899 11 telefax +358 3 899 428 export@kemppi.Com www.Kemppi.Com kotimaan myynti: tel +358 3 899 11 telefax +358 3 734 8398 myynti.Fi@kemppi.Com kemppi sverige ab box 717 s-194 27 upplands vÄsby sverige tel +46 8 590 783 00 telefax +46...