    Built-in fully-automatic coffee machine ekv 6600.0

  • Page 2

    Service manual: h6-72-01 responsible: mario kühne kÜppersbusch hausgerÄte ag email: mario.Kuehne@kueppersbusch.De tel.: (0209) 401-756 kundendienst fax: (0209) 401-743 postfach 100 132 date: 21.12.06 45801 gelsenkirchen.

  • Page 3

    3 for internal use only contents 1. Safety ............................................................................................................................... 5 2. Safety instructions ...........................................................................................................

  • Page 4

    4 for internal use only 12. What is to be done if … ................................................................................................ 30 12.1 … “water tank empty“ is not shown? .................................................................. 30 12.2 … ventilate “permanently“ is show...

  • Page 5

    5 for internal use only 1. Safety • because of the universal cut-off device (relay and manometric switch), on measuring the connector plug in accordance with vde 0701, the boiler must be tested for insulation faults by means of direct measurement, or the differential current of the appliance must be...

  • Page 6

    6 for internal use only 2. Safety instructions • the appliance may only be connected to a suitable wall outlet. Do not remove the plug from the socket by pulling on the cable! Do not use any extension cables in wet rooms. • the power supply must correspond to the information on the nameplate. Recomm...

  • Page 7

    7 for internal use only 3. Your appliance at a glance n bar handle to open the panel o clear text display p control panel q rotating knobs for aroma control r nozzle s service flap t coffee dispenser drip tray u box for coffee grounds v drip tray m display for drip tray n o n q r t m s o p u v ¬.

  • Page 8

    8 for internal use only fittings n red clear text display o box for coffee beans p water tank q main switch r adjusting the grinding setting s brewing unit the features • led lighting • central switch-off device • adjustable coffee dispenser height • electronic push buttons • electronic clock with a...

  • Page 9

    9 for internal use only 4. Technical data 4.1 general this service manual serves the purpose of providing customer service technicians who already have the know-how required to repair coffee machines with specific information on the operating mode of the appliances indicated on the front page. Overa...

  • Page 10

    10 for internal use only 5. Installation 5.1 instructions for installation • statutory regulations and the connection specifications issued by the local power supply company must be strictly observed. • prior to connecting the appliance to the mains ensure that the power supply complies with that fo...

  • Page 11

    11 for internal use only 5.3 installation in a top unit 5.4 installation in a tall unit at least 570mm (without a front door at least 550mm).

  • Page 12

    12 for internal use only the height can possibly be regulated with the adjusting screw (clearances, flush mounting)..

  • Page 13

    13 for internal use only 6. Button assignments 6.1 pre-set button assignment when the control panel has been opened up various beverages can be selected simply by pressing a button. The buttons have been assigned in the factory. The individual user settings can be set with the electronic push button...

  • Page 14

    14 for internal use only 7. User settings 1. Start with p 2. Select a function 3. Making settings exit with esc select confirm select confirm exit function display setting and display standby standby the machine switches into the power-down mode at 3-4 w rinsing the cycle is automatically cleaned wh...

  • Page 15

    15 for internal use only function display setting and display aroma espresso aroma espresso choosing the quantity of ground coffee for espresso between 6.87, 8.5 and over 10g/s for 80 - 122 impulses. Aroma coffee aroma coffee choosing the quantity of ground coffee between 1.3 and 1.5g/s for approx. ...

  • Page 16

    16 for internal use only 8. Fittings 8.1 aroma control operation for standard grinder setting aroma control enables the machine to be set individually according to a customer's wishes, from american weak to italian strong, simply by turning the aroma knob. Maximum setting – for a light coffee, café ...

  • Page 17

    17 for internal use only 8.3 grinder in order for the coffee beans to develop their full flavour to perfection, they must firstly be ground to just the right fineness. The excellent quality of the innovative ceramic grinder guarantees that you will be able to enjoy perfect coffee. The first-class gr...

  • Page 18

    18 for internal use only 9. Aquaprima water filter the best ph level for a good cup of coffee is in the neutral range of between 6.5 and 7.5. Coffee will taste bitter if the ph is higher. On the other hand, if it is lower coffee will take on a slightly tart taste. Water hardness defines the lime con...

  • Page 19

    19 for internal use only if the machine is operated with the aquaprima water filter, the “water filter – on“ setting should be activated in the user settings. This means that only every second cycle of the water flow-through metre is registered as an impulse, so that the machine only needs to be des...

  • Page 20

    20 for internal use only 10. Accessing individual components grinder motor pump steam boiler excess pressure power module micro fuses coffee water valve safety fuse excessive boiler safety fuse temperature valve z the brewing unit must be set at zero before the brewing system is installed. Service f...

  • Page 21

    21 for internal use only 10.1 coffee dispenser the coffee dispenser will need to be replaced if it no longer engages properly since this means that the catch is defect. 1. Remove the entire flap. Final switch brewing unit normal position final switch service flap brewing unit drive final switch brew...

  • Page 22

    22 for internal use only 2. Loosen the screws and remove the metal plate inserted in the door. 3. Remove the brass bush with the lock washer and then the hinge. 4. Remove the other screws. 5. Pull the coffee dispenser right out. 10.2 door lock 1. Loosen the screws. 2. Pull the lock upwards. Z attent...

  • Page 23

    23 for internal use only 10.3 aromacontrol the full element can only be replaced if the door is dismantled. However, the valve may also be replaced without a casing. In this case the door will not need to be dismantled. 1. Remove the cover with a small screw driver, making sure that the casing is no...

  • Page 24

    24 for internal use only 10.5 hot water nozzle 1. Loosen the splint. 2. Remove the screws. 3. Swing the swivel nozzle out towards the front. 4. Turn it by a ¼ turn and pull it out. Assembly 5. First push the nozzle and then turn it by a ¼ turn until it engages. 6. Pay attention to the teflon ring an...

  • Page 25

    25 for internal use only 10.6 brewing unit sieve z attention! Carefully tighten the sieve with a spanner or by hand. If the sieve is too tight the brass bush may loosen and come out of the shell. This may cause the brewing unit to get stuck..

  • Page 26

    26 for internal use only 11. Care and maintenance 11.1 cleaning clean the machine, the brewing unit and the accessories once a week under running water, without any detergent. Never rinse parts of the machine in the dishwasher and never dry them in the oven or in the microwave. Water tank / coffee b...

  • Page 27

    27 for internal use only coffee dispenser 1. Press the coffee dispenser to the back. Slide the drip safeguard onto the aromacontrol and remove the drip tray. 2. Open the service flap. The push button is located behind the cover. 3. Press the button at the top and pull the coffee dispenser towards th...

  • Page 28

    28 for internal use only nozzle 1. Pull the lower part of the nozzle downwards. 2. Rinse it under running water without any detergent. 11.2 descaling the machine can either be descaled when it becomes necessary or when the display shows descale. Do not under any circumstances use vinegar since this ...

  • Page 29

    29 for internal use only preparation and descling 1. Remove the water filter. 2. Fill in the antiliming agent in accordance with the producer's instructions and dilute it with at least 1l of water. The descaling cycle will not run properly if this is not done. 3. Replace the water tank. 4. Place a l...

  • Page 30

    30 for internal use only 12. What is to be done if … 12.1 … “water tank empty“ is not shown? The water level is variable and is considered to be empty at approx. 22mm. As of this reed switch impulse the water metre will transmit 900 impulses. This will always be sufficient for any cup size until the...

  • Page 31

    31 for internal use only possiblity 2: the water tank has developed a leak 1. Check to ensure that the valve has not become calcified and/or that the o ring is not defect. 2. To do so screw the o ring off. 3. Remove the valve. 4. Clean the parts and replace them if necessary.. 12.3 … water is not di...

  • Page 32

    32 for internal use only 3. Remove the nozzle and replace it completely with the o rings. 12.4 ... The drip tray drops down? Cut a piece off the grid under the tray. 12.5 … coffee bean box does not close? • no beans may be in the funnel above the grinder. • the cover is defect. 12.6 … coffee is not ...

  • Page 33

    33 for internal use only 12.7 ... Coffee tastes bitter? • the brewing temperature is above 92°c. - set the temperature at 88, 90 or 92°c. • the pump pressure is less than 9bar, i.E. The pump may have become calcified. • the grinder setting is too fine and must be adjusted. • there is too much coffee...

  • Page 34

    34 for internal use only 12.11 … faults develop during operation? 12.12 … the following messages are shown? The machine does not switch on. • switch on the main switch. • check the power connection. • check the fuses of the house wiring system. Coffee is not hot enough. • pre-heat cups with hot wate...

  • Page 35

    35 for internal use only 13. Test and diagnosis program 13.1 tests carried out on component and function test mode when the machine is switched on press s2 twice in order to access the standby mode. Please proceed as follows to get into the test mode: 1. In the standby mode press buttons s3 and s6 a...

  • Page 36

    36 for internal use only s3 button grinding function • check that turning the button anti-clockwise for brewing functions correctly. • check the grinding noises. • when the motor for grinding is in operation the display will show the reference setting of the motor speed on the bottom right-hand side...

  • Page 37

    37 for internal use only 13.2 testing the microswitch display microswitch function 1 brewing unit switch moving determines the final position of the upward movement of the unit. 2 brewing unit switch in the normal position determines the final position of the downward movement of the unit. 3 control...

  • Page 38

    38 for internal use only 14. Heating diagram temperature measured in the boiler 1. Coffee 117°c temperature high 110°c previous coffee temp. Normal 90°c temperature measured in the boiler 1. Coffee 117°c temperature high 110°c temp. Rise 0 - 50°c temp. Normal 90°c temperature definition example: tem...