Six-source six-zone music distribution amplifier khs6640 owners manual six-zone amplification system model khs6640 on power standby the khs6640 is a six source, six zone music distribution amplifier that will fill your home with the highest quality music of any system being built today. It offers u...
This apparatus shall not be exposed to dripping or splashing. No objects filled with liquids such as vases shall be placed on the apparatus. To avoid electrical shock, do not disassemble. Refer servicing to qualified personal only! Kustom inc., 4940 delhi pike, cincinnati, oh usa (800) 999-5558 fa...
A.) power switch - left on, the khs6640, when not being used, will go into a sleep mode, ready to turn back on when an input signal is applied from any of the six sources. In the off position, the unit will not function. B.) on led - with the power switch on, this led indicates that the unit is po...
Zone 1 l r left - + right - + zone 2 l r left - + right - + zone 3 l r left - + right - + zone 4 l r left - + right - + zone 5 l r left - + right - + zone 6 l r left - + right - + line out / speaker out 20w/8 ohm x2 20w/8 ohm x2 20w/8 ohm x2 20w/8 ohm x2 20w/8 ohm x2 20w/8 ohm x2 line out line out l...
Zone controllers 1 8 out 1 8 1 8 1 8 1 8 1 8 1 8 1 8 in 1 2 3 4 5 6 master individual zones controller section 7.) master output - this connector allows the party mode to apply to multiple units if additional units are added. 8.) master input - this is for the party mode controller. This control...
Avis: risque de choc electrique-ne pas ouvrir. Warning: shock hazard - do not open. Ir remote outputs 1 source output sum output a 2 b 3 c 4 d infrared (ir) section 16.) source output #1 through 4 - this 1/8 2 conductor jack is for the ir emitters and are locked source specific. This is useful in...
Khs6640 installation manual.
Page 1 khs6640 installation manual recommended cables: category-5 or category-3 (4 twisted pair stranded), shielded or unshielded. 16-4 or (2) 16-2 speaker cables. To keep the installation process as simple as possible for first time users, please follow these simple steps. These instructions are wr...
Master in/out: the master controller input will accept a seventh khs6s controller. This controller will then become a master control for the entire system. If source 1 is selected on this controller, all zones will switch to source 1. If volume up is pressed, all zones will go up and visa versa vo...
Page 3 ir emitter modulation frequency - these are factory set to give optimum preformance of the emitters. Factory setting is 40khz. Range is 32 khz full ccw to 65 khz full cw. Doorbell level - adjust to onboard doorbell chime to appropriate level. Factory setting -10db page level - adjust to set p...
Page 4 page out speaker out doorbell + + + - - - strike 1 strike 2 chimes audio mute doorbell a doorbell b unit on trigger on + - khs6640 te-200 +15vdc + - 9vdc-12vdc /100ma power supply 15vdc power supply - + 470 1/2w this is alternative wiring using existing power supply. This supply is not needed...
Page 5 audio mute doorbell ab panasonic kxta624 khs6640 doorphone doorphone adapter (back) page out phone jacks co s gv out to phones in from telco shielded cable recommended standard hook-up wire standard hook-up wire neg pos tr? Doorbell xformer ac input these wires can also come directly from doo...
1.) ir sensor - this is an infrared sensor window. We suggest you aim the external remote control directly at this window to pass commands back to and through the unit. 2.) source selector buttons (1 - 6) - these buttons will select the source you want to listen to. Individual key caps (supplied wit...
Khs6d controller 8.) reset - this resets the local zone controller if an ir command locks up the zone. It will not erase the local zone memory. It will just send a local clear command. 9.) clear - this button has 3 modes: a.) device mode - will clear learned commands from the local zone memory. If...
Khs6d controller (contd) 16.) numeric entry keys (0 - 9) - depending on the mode you are in these keys will allow direct track access on a cd, an individual station on tv or dss, or a station on a tuner, etc. If you are in the macro mode, these will allow direct access to your stored macros. 17.) e...
The khs6d controller is designed to learn and store ir codes for virtually any piece of audio/video equipment. This enables the individual programming and use of multiple functions for all of your source components. Programming individual functions 1) press the learn button on the controller. The ...
Macro programming the khs6d has 16 programmable macro memories. It will automatically transmit a series of 20 commands deep. To enter the macro mode - press macro and the either the 0 through 9 buttons or the device source keys (1-6). You can insert a delay time from 1 to 99 seconds between steps (t...
Page 11 1) remove the decora cover plate, and controller face plate. 2) place your wireless remote in learn mode. 3) select the device bank button to program (i.E. Tv, vcr, tuner, aux, etc.) on the wireless remote. 4) select the button to be programmed on the learning remote. (i.E. 1-6, mute, or vol...
Can i control volume and source selection with a wireless remote? Yes, the khs6s and the khs6d controllers have a built-in ir emitter that will teach learning remote the kustom ir codes for volume, source selection, and mute. How do i control ir if i am using more than one 6640 amplifier? The best s...
Page 13 you are using the paging and or doorbell hook-ups on the back of the khs6640, disconnect these. If the page audio inputs are causing the muting then try adjusting the page sensitivity pot in the inside of the 6640 (see the owners manual). Sometimes it is necessary to reset the 6d controlle...
Installation notes date of purchase: _________ date of install: ____________ serial number of unit: __________________________________ installing company: ___________________ name: __________ installers address: __________________________________________________ installers phone: _________________...
Additional notes: p a g e 1 5.
Specifications power output: 20 watts at 6 ohms x 12 frequency response: 20 hz-20 khz (+/- 1 db) t.H.D.: 0.2% or less @ rated power signal/noise ratio: >80 db (a weighted) slew rate: 10v/u sec. Input impedance: 10k ohms input sensitivity: -10 dbv for rated output voltage trigger in: 5 volts to 12 vo...