  • Page 1

    Kerosene high pressure portable forced air heaters owner’s manual ® fill in for your records model no. ___________________ (located on side panel) serial no. ___________________ (located on fuel tank) date of purchase: ______________ 350 side pv 026 with thermostat heater sizes: 350,000 and 600,000 ...

  • Page 2: Safety Information

    105850-01d 2 safety information danger: carbon monoxide poisoning may lead to death! Warnings important: read this owner’s manual carefully and completely before trying to assemble, operate, or ser- vice this heater. Improper use of this heater can cause serious injury or death from burns, fire, expl...

  • Page 3: Product Identification

    105850-01d 3 3 product identification figure 1 - 350,000 btu/hr model upper shell power cord thermostat fuel cap fuel tank hot air outlet lower shell flame-out control reset button hot air outlet unpacking 1. Remove all protective packing applied to heater for shipment. 2. Remove heater from shippin...

  • Page 4: Fuels

    105850-01d 4 fuels warning: follow the minimum fresh, outside air ventilation requirements. If proper fresh, outside air ventilation is not provided, carbon monoxide poison- ing can occur. Provide proper fresh, outside air ven- tilation before running heater. Ventilation fresh air opening requiremen...

  • Page 5: Operation

    105850-01d 5 5 operation continued to stop heater caution: never unplug heater while heater is running. Heater must go through purge cycle. The purge cycle cools the combustion chamber. Damage to heater can occur if combustion chamber is not cooled. Do not restart heater until purge cycle is complet...

  • Page 6: Preventative

    105850-01d 6 preventative maintenance schedule item fuel tank filler neck screen fuel filter assembly (fuel tank) fuel filter lines fuel filter (in pump or external canister) spark plug fan blades and air deflectors air passages around burner head motor warning: never service heater while it is plug...

  • Page 7: Troubleshooting

    105850-01d 7 7 troubleshooting observed problem heater will not ignite, but motor runs for a short period of time. 1. A) add fuel to tank b) check fuel tank for bubbles of water in bottom. If found, remove fuel (see storing, transporting, or shipping, page 5). Clean tank and fuel filters (see fuel f...

  • Page 8: Troubleshooting

    105850-01d 8 upper shell observed problem heater ignites, but flame-out control shuts off heater after a short period of time heater burns, but puffs of smoke can be seen heater does not burn steady heater burns with odor heater smokes continuously 1. Wrong pump pressure 2. Dirty fuel filters 3. Dir...

  • Page 9: Service Procedures

    105850-01d 9 9 service procedures service procedures continued figure 7 - fan blades and air deflectors fan blade air deflector fan blades and air deflectors 1. Remove upper shell (see upper shell removal, page 8). 2. Clean fan blades and air deflectors with clean, soft cloth moist- ened with kerosene...

  • Page 10: Service Procedures

    105850-01d 10 service procedures continued service procedures figure 11 - adjusting pump pressure figure 13 - location of screw on flange clamp hex screw on flange clamp fuel lines (procedure for tightening fuel lines) 1. Remove upper shell (see upper shell removal, page 8). 2. Use an adjustable wre...

  • Page 11: Service Procedures

    105850-01d 11 11 service procedures service procedures continued fuel line solenoid valve burner head fuel pump figure 15 - fuel line at solenoid valve figure 16 - fuel lines at pump fuel lines fuel filter fuel lines figure 17 - removing tank fuel filter fuel pump (filter under cover) figure 19 - fu...

  • Page 12: Illustrated Parts

    105850-01d 12 illustrated parts breakdown 350,000 btu illustrated parts breakdown 1 2 2 4 5 21 2 7 8 9 10 13 11 12 14 15 16 19 20 21 4 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 37 38 34 2 39 2 40 4 6 20 13 3 17 18 41.

  • Page 13: Parts List

    105850-01d 13 13 parts list parts list 350,000 btu this list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under repair service on the back page of this manual. Ref. No. Part no. Description qty. 1 130-20768 upper shell 1 2 130-20805 screw, #10-1...

  • Page 14: Illustrated Parts

    105850-01d 14 illustrated parts breakdown illustrated parts breakdown 600,000 btu 1 2 2 3 4 5 13 6 7 45 46 8 9 10 11 13 14 21 18 17 15 16 23 22 24 25 33 2 4 28 30 26 27 34 25 16 2 35 36 41 42 15 43 43 44 39 38 37 15 29 12 40 2 19 20 2 4 31 32 47.

  • Page 15: Parts List

    105850-01d 15 15 ref. No. Part no. Description qty. 1 130-21889 upper shell 1 2 130-20805 screw, #10-16 x 1/2" 28 3 130-21890 combustion chamber & shield 1 4 130-20931 bushing 5 5 130-21891 air deflector 5 6 † burner head assembly 1 7 130-21892 photocell assembly 1 8 130-21893 fan 1 9 130-21894 fan g...

  • Page 16: Part List

    105850-01d 16 ref. No. Part no. Description qty. 1 130-20868 wiring cover 1 2 130-20819 screw, 5/16-24 x 5/16" 4 3 130-20820 external lockwasher, 5/16" 4 4 130-20806 screw, #10-16 x 3/8" 3 5 130-20870 motor (350,000 btu/hr) 1 130-21912 motor (600,000 btu/hr) 1 6 130-20866 flange clamp (holds pump to...

  • Page 17: Part List

    105850-01d 17 17 ref. No. Part no. Description qty. 1 130-20868 wiring cover 1 2 130-20819 screw, 5/16-24 x 5/16" 4 3 130-20820 external lockwasher, 5/16" 4 4 130-20806 screw, #10-16 x 3/8" 3 5 120-20870 motor (350,000 btu/hr) 1 130-21912 motor (600,000 btu/hr) 1 6 130-20866 flange clamp (holds pump...

  • Page 18: Specifications

    105850-01d 18 specifications 350,000 btu/hr 600,000 btu/hr output rating (btu/hr) 350,000 600,000 fuel use only kerosene or no. 1 fuel oil fuel tank capacity (u.S. Gallons) 30 36 fuel consumption (gallons per hr) 2.5 4 electric requirements 120v/60 hz 120v/60 hz amperage (normal run) 7.1 11 motor rp...

  • Page 19: Notes

    105850-01d 19 19 notes _______________________________________________________________________________________________ _______________________________________________________________________________________________ _____________________________________________________________________________________...

  • Page 20: II. General Information

    105850-01d 20 for purchasing l. B. White. This l. B. White heater incorporates the benefits from the most experienced manufacturer of heating products using state-of-the-art technology. If you have any suggestions or comments, please call us toll-free at 1-800-345-7200 or write or fax us at: l.B. Wh...