SET TIME:
12/24-HOUR TIME: Hold the CF/SET button until 12hr or 24hr flashes in the lower
right hand corner. Press and release the MIX/MAX/+ button to switch between 12-hour
and 24-hour time. Press the CF/SET button once to continue.
HOUR: The Hour will flash. Press and release the MIX/MAX/+ button to change the
hour. Press the CF/SET button once to continue.
MINUTES: The minutes will flash. Press and release the MIX/MAX/+ button to change
the minutes.
NOTE: Hold the MIX/MAX/+ button to move quickly through the numbers. Press
CF/SET once to confirm and exit.
TEMPERATURE SELECTION:
FAHRENHEIT/CELSIUS: Press and release the CF/SET button once to switch from Fahrenheit to
Celsius.
FOUR LEVEL RF INDICATORS: The temperature station will indicate strength of signal
reception from the outdoor transmitter by the number of bars on the RF
indicator icon.
4-bars: Shows after initial set up and stays when reception is at full strength.
3-bars: Indicates one reception failure from the outdoor transmitter.
2-bars: Indicates two reception failures from the outdoor transmitter.
1-bar: Indicates three reception failures from the outdoor transmitter.
0-bars: Indicates four reception failures from the outdoor transmitter.
The antenna symbol will flash on initial set while searching for the signal. If it fails to receive a signal after
63 minutes the temperature station will display dashes (“--.-“). The temperature station will search again
for a signal for 3 minutes every next hour.
MIN/MAX RECORDING:
VIEW MIN/MAX: Press the MIN/MAX/+ button view indoor and outdoor MAX, MIN and Current
temperature.
RESET MIN/MAX: Hold the MIN/MAX/+ button for 3 seconds to reset all MIN/MAX readings to current
temperatures.
OUTDOOR TRANSMITTER RESET BUTTON:
The Temperature Transmitter has a RESET button. Use a small pointed object to gently press and
release to send a signal. Follow the instructions for in SET UP regarding the display.
NOTE: Removing power from the transmitter and display negates the need for the RESET button.
POSITIONING THE TEMPERATURE STATION:
Stand the Temperature Station on a tabletop, counter or desk, or mount on a wall. Ensure that the
Temperature Station continuously receives the 433MHz signal from the Sensor before mounting it in the
desired location.
WALL MOUNT
Install a mounting screw (not included) into a wall
—leaving approximately 3/16 of an
inch (5mm) extended from the wall.
Place the Temperature Station onto the screw, using the hanging hole on the
backside. Gently pull the Temperature Station down to lock into place.
NOTE: Always ensure that the Temperature Station locks onto the screw before
releasing the station.
TABLE STAND: The Temperature Station has a wide base to stand on a desk or table.