La Crosse WS9008UIT Manual

Summary of WS9008UIT

  • Page 1

    1 temperature station model ws9008uit instruction manual introduction: congratulations on purchasing this innovative 915mhz temperature station which displays indoor and outdoor temperature. To enjoy the full benefits of this innovative product, please read this operating manual. « instant transmiss...

  • Page 2

    2 features: the temperature station temperature display in degrees celsius (°c) or fahrenheit (°f) selectable indoor and outdoor temperature display with min/max recording function keys foldout stand battery compartment cover lcd display hanging hole.

  • Page 3

    3 all indoor and outdoor min/max recordings can be reset seperately low battery indicator wireless transmission at 915 mhz outdoor signal reception intervals at every 27.5 seconds table standing or wall mounting the outdoor temperature transmitter remote transmission of outdoor temperature to temper...

  • Page 4

    4 setting up: note: the temperature station will receive one outdoor transmitter only. 1. First, insert the batteries into the temperature transmitter. (see “install and replace batteries in the temperature transmitter“). 2. Immediately after and within 1 minute, insert the batteries into temperatur...

  • Page 5

    5 install and replace batteries in the temperature station the temperature station uses 2 x aa, iec lr6, 1.5v batteries. To install and replace the batteries, please follow the steps below: 1. Remove the cover at the back of the weather station. 2. Insert batteries observing the correct polarity (se...

  • Page 6

    6 2. Insert the batteries, observing the correct polarity (see marking). 3. Replace the battery compartment cover on the unit. Note: in the event of changing batteries in any of the units, all units need to be reset by following the setting up procedures. This is because a random security code is as...

  • Page 7

    7 function keys: temperature station: the temperature station has 2 easy to use function keys. In/out key to toggle between the indoor and outdoor temperature display press and hold to toggle between the temperature display of degree celsius (°c) and fahrenheit (°f) min/ max key to toggle between th...

  • Page 8

    8 press and hold to reset the min/max outdoor temperature records to the current outdoor temperature (if the outdoor temperature is displayed) lcd screen and settings: temperature display in ºc or °f receiver low battery outdoor signal reception icon* transmitter low battery icon.

  • Page 9

    9 * when the outdoor signal is successfully received by the temperature station, this icon will be switched on. (if not successful, the icon will not be shown in lcd) so user can easily see whether the last reception was successful (icon on) or not (icon off). Display of indoor temperature reading a...

  • Page 10

    10 display of outdoor temperature reading and outdoor min/max records: 1. Press the in/out key to view the current outdoor temperature 2. Press the min/max key to view the min record 3. Press again the min/max key to view the max record. 4. Press the min/max once more to return to current outdoor te...

  • Page 11

    11 resetting the min/max records when the indoor temperature is displayed, press and hold the min/max key for about 2 seconds to reset the indoor min/max temperature records to the current indoor temperature. When the outdoor temperature is displayed, press and hold the min/max key for about 2 secon...

  • Page 12

    12 1. The distance of the temperature station or transmitter should be at least 1.5 to 2 metres away from any interfering sources such as computer monitors or tv sets. 2. Avoid positioning the temperature station onto or in the immediate proximity of metal window frames. 3. Using other electrical pr...

  • Page 13

    13 positioning the temperature station: the temperature station has been designed to be hung onto a wall or free standing. To wall mount choose a sheltered place. Avoid direct rain and sunshine. Before wall mounting, please check that the outdoor temperature values can be received from the desired l...

  • Page 14

    14 positioning the temperature transmitter: the transmitter is supplied with a holder that may be attached to a wall with the two screws supplied. The transmitter can also be positioned on a flat surface by securing the stand to the bottom of the transmitter. To wall mount: 1. Secure the bracket ont...

  • Page 15

    15 care and maintenance: extreme temperatures, vibration and shock should be avoided as these may cause damage to the unit and give inaccurate forecasts and readings. Precautions shall be taken when handling the batteries. Injuries, burns, or property damage may be resulted if the batteries are in c...

  • Page 16

    16 do not expose the units to extreme and sudden temperature changes, this may lead to rapid changes in forecasts and readings and thereby reduce their accuracy. Specifications: temperature measuring range: indoor : -9.9°c to +59.9°c with 0.1°c resolution/ +14.2°f to +140°f with 0.2°f resolution (“o...

  • Page 17

    17 temperature transmitter : 2 x aaa, iec, lr3 1.5v battery life cycle (alkaline batteries recommended): temperature station : approximately 24 months temperature transmitter : approximately 12 months dimensions (l x w x h): temperature station : 74 x 29.1 x 98mm temperature transmitter : 32.4 x 14....

  • Page 18

    18 distributed by: sontax australia phone: 1800 653 238 email: sales@sontax.Com.Au website: www.Sontax.Com.Au ws9008uit printed in china.