La Pavoni EUROPICCOLA EPBB-8 Instructions For Use Manual - page 7
TECHNICAL PRECAUTIONS
I
1.
Install the machine on a steady, dry base.
2.
DO NOT immerse the machine or power cord in water.
3.
This machine develops warm spots (base) and hot spots (boiler 9). Subsequently, it should be kept
out of the reach of children.
4.
When operating, please take note of the hot surfaces.
OPERATING PRECAUTIONS
1.
Never operate this unit without sufficient water in the boiler (9) failure to maintain proper water
level can cause damage to internal parts.
2.
Never attempt to open the boiler cap (3) when the machine is in operation. The la Pavoni operates
on a hot water/steam pressure method. Opening the boiler cap when the machine is on and
pressure will result in the sudden release of hot water. If you would like to add water to the boiler,
then follow these precautions:
a.
Turn the machine off (6)
b.
Unplug the machine
C.
Release the existing steam in the boiler (9) via the steam tube (12). This is
accomplished by turning the steam knob (4) counterclockwise. After
ALL
the
steam has finished escaping, you may slowly open boiler cap.
3.
After making coffee, never remove the coffee handle until remaining coffee in the filter has
been allowed to drip out. Always remove this handle
to allow excess steam to
escape.
Your espresso machine is equipped with a manual reset fuse.
Should the
water level in the sight glass drop below a
1 5 of a tank or if the machine is left
on indefinitely, these occurrences may cause the machine to over-heat. If the
on/off switch does not light up the fuse may have blown, follow the below steps
to restart your machine.
1. Unplug the unit
2. Close the boiler knob tightly so water does not escape
3. Gently place the machine on its side.
Under the base of the unit you will notice a round grommet plug inserted into
the bottom, directly under the boiler tank.
Remove the plug and push in the
protruding red switch by using a blunt instrument (the end on a pencil of pen
works well) replace the grommet, add water if necessary, plug-in and restart.