Laars LMC User manual

Manual is about: Modulating Boiler Model LMH 125 MBTU/h Combination Boiler and Water Heater Model LMC 125 MBTU/h

Summary of LMC

  • Page 1

    User’s manual document 1239a h2338600a warning if the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other a...

  • Page 2

    Laars heating systems page 2 figure 2. Location of components. Contents familiarizing yourself to the laars mascot ii ................2 1. Caring for your mascott ii ........................................3 2. Filling, shut down and restart ...............................3-4 3. Digital display and ...

  • Page 3

    User’s manual - mascot ii boilers and water heaters page 3 1. Caring for your mascot ii your mascot ii will require very little maintenance. However, as with any fine appliance there are certain steps that should be taken to ensure continuing optimum performance. 1.1 general care keep the area aroun...

  • Page 4

    Laars heating systems page 4 shut off the manual gas valve, and call the unit for heat. Main gas valve will be energized, attempting to light, for four (4) seconds, and then will de- energize. The unit will go into lockout after the required number of trial for ignition periods. Press the manual res...

  • Page 5

    User’s manual - mascot ii boilers and water heaters page 5 figure 3. The user interface. The mascot ii has an integrated electronic control that replaces many of the individual component controls found on older appliances. The control acts as the ignition control, pump control, high limit and cascad...

  • Page 6

    Laars heating systems page 6 3.2 ignition control- sequence of events 1. Call for heat 2. Safety chain check 3. Fan starts. 4. Prepurge timer is started. 5. Preignitiontimeof2secondstochecktheflame sensor operation and status. 6. Trial for ignition period, 4 seconds. The direct spark ignition switch...

  • Page 7

    User’s manual - mascot ii boilers and water heaters page 7 3.8 lead lag / cascading lead lag/cascading allows multiple boilers to be connected together and controlled from one common sensor input. Up to 8 boilers can be connected together in a single system. To setup lead/ lag or cascading operation...

  • Page 8

    Laars heating systems page 8 h2338600a 800.900.9276 • fax 800.559.1583 (customer service, service advisors) 20 industrial way, rochester, nh 03867 • 603.335.6300 • fax 603.335.3355 (applications engineering) 1869 sismet road, mississauga, ontario, canada l4w 1w8 • 905.238.0100 • fax 905.366.0130 www...