Lab.gruppen fP Series FP 2400Q User Manual

Other manuals for fP Series FP 2400Q: Brochure, Specifications, Service Manual

Summary of fP Series FP 2400Q

  • Page 1

    Ñm=oqmmn= rpbo=j^kr^i= =.

  • Page 2: N= `lkqbkqp=

    N= `lkqbkqp= 1 contents .......................................................................................................................................1 2 approvals...................................................................................................................................

  • Page 3: O= =^mmols^ip=

    10 maintenance.........................................................................................................................17 10.1 troubleshooting........................................................................................................................17 11 specifications ....

  • Page 4

    9. Connect only to ac power outlets rated 200-240v, 50-60hz. 10. Do not use this amplifier if the power cord is broken or frayed. Protect the power cord from being walked upon or pinched particularly at the plugs and the point where it exits from the apparatus. 11. Only use accessories specified by ...

  • Page 5: Q= Fkqolar`qflk=

    • check if the affected unit complies with the emc limits for immunity, (ce-labelled). If not, address the problem with the manufacturer or supplier. All electrical products sold in the ec must be approved for immunity against electromagnetic fields, high voltage flashes, and radio interference. • c...

  • Page 6

    5. Clip/limit indicator this indicator signals if the amplifier output is clipping or limiting. It has two different indication states: if the clip limiter is engaged, it has a short time constant, and it illuminates briefly. If the clip limiter is not engaged, it has an increased time constant, and...

  • Page 7: R= Ob^o=M^kbi=Cb^qrobp=

    R= ob^o=m^kbi=cb^qrobp= before turning the amplifier on please read the following sections to make sure that the unit is set up properly for your specific application. Rknkn= d~áå= the gain of the fp 2400 is fixed to 32 db rknko= pÉåëáíáîáíó= sensitivity is defined as how many volts (rms) or dbu (re...

  • Page 8

    Rko= iáåâ=ëïáíÅÜ= the link switches located on rear panel (switches between the four xlr input connectors) are for changing the operation mode of the amplifier. (see below, section 5.3). Rkp= léÉê~íáçå=ãçÇÉë= rkpkn= píÉêÉç=ãçÇÉ= in this mode, both channels operate independently of each other. This i...

  • Page 9

    Rkpkq= _êáÇÖÉ=ãçåç=ãçÇÉ= bridge mono mode is used to deliver two channels' power to a single load. The nominal impedance of the load must be more than 3 ohms. Set the link switch to the pressed –“in”-position and use one of the input connectors. You can use the remaining input connectors to carry si...

  • Page 10

    Rkq= fãéÉÇ~åÅÉ=ã~íÅÜáåÖ=ejip=ëïáíÅÜf= the mls tm switch is located on the rear panel. The mls (minimum load select) switch offer impedance matching, so you can drive the fp 2400q into 2 ohms without increased heat loss. As stated earlier, the fp 2600can produce 380 watts into both, 2 and 4 ohms. Use...

  • Page 11: S= Fkpq^ii^qflk=

    Headroom for low impedance loads. The amp runs at higher efficiency, and the risk for going into thermal protection is significantly lower. Rkqko= jip=íÉÅÜåçäçÖó=Ó=íÜÉ=Ä~ÅâÖêçìåÇ= rkqkp= qÜÉ=éêçÄäÉã= assume that a power amplifier can deliver 1000 watts into 8 ohms, and it should be able to run also ...

  • Page 12

    Skp= léÉê~íáåÖ=îçäí~ÖÉ= warning! A label just below the mains cable on the rear of the amplifier indicates the ac mains voltage for which the amplifier is wired. Connect the power cable only to the ac source referred to on the label. The warranty will not cover damage caused by connecting to the wro...

  • Page 13: T= `lkkb`qflkp=

    Last, the "regular operating power" as defined by the safety standard iec 65/ansi/ul 6500 and used by a majority of safety agencies. The regular operating power is measured by using pink noise, and with an average output power equal to 1/8 of full power. The one eighth of the total power is as loud ...

  • Page 14

    Figure 4. Xlr input connector figure 5. Xlr balanced ojack there is a ¼”(6.3mm) phone jack, which is wired in parallel with the lr. Hot ing cold round within the neutrik® comb x tip r sleeve shield/g figure 6. ¼” trs plug the igh enough (20 kohms balanced) to allow ”daisy-chaining”, or multiple nput...

  • Page 15: U= Lmbo^qflk=

    Channel a and b (or c and d) into one speakon. . (quad or bi-amp) bridged mono never connect either output terminal to ground or to some other output or input terminal. For normal four-channel operation, connect each speaker load across the output’s positive and negative terminals. Pay attention to ...

  • Page 16: V= Molqb`qflk=Cb^qrobp=

    Ukq= fåÇáÅ~íçêë= the yellow led’s on the top, indicate if any protection circuits are activated. The protections a described further below on this page ( 15 re ). The clip indicator tells if the amplifier output is clipping or limiting. It has two different indication statuses: • if the clip limiter...

  • Page 17

    Vknkp= sec=éêçíÉÅíáçå= if a signal above 12khz is detected at the amplifier outputs for more than five seconds at full output power, the vhf protection mutes the input signal. This is indicated by the led’s on the front panel labeled protect. After five seconds the outputs will un-mute and return to...

  • Page 18: Nm=J^fkqbk^k`b=

    Nm=j^fkqbk^k`b= under normal use the amplifier should provide years of trouble-free service. The only user maintenance required by the user is to vacuum the front grill periodically. In some extreme cases it may be necessary for authorized service personnel to clean the inside of the amplifier. Thes...

  • Page 19: Nn=Pmb`fcf`^qflkp=

    Nn=pmb`fcf`^qflkp= i~ÄkÖêìééÉå== = = = = ====================== ======================== nu rëÉê=j~åì~ä===Ñm=oqmm=n=====sÉêëáçå=mku========ommpjnmjmt=.

  • Page 20: No=T^oo^kqv=

    No=t^oo^kqv= general this product is manufactured by lab.Gruppen and is warranted to be free from defects in components and factory workmanship under normal use and service for a period of three (3) years from the date of original purchase from an authorised lab.Gruppen dealer. When failing to perfo...