Lab.gruppen iP Series IP 900 Specifications - Specifications Ip 900
SPECIFICATIONS iP 900
Lab.gruppen AB, Gullregnsvägen 16, S-434 44 Kungsbacka, Sweden.
Tel. +46 300 168 23. Fax +46 300 142 46. e-mail: info@labgruppen.se www.labgruppen.se
LAB. GRUPPEN reserve the right to alter functions or specifications without prior notice.
MAX OUTPUT POWER
1)
EIA at 1 kHz and 1% THD FTC 20-20kHz @0.1%THD
8
Ω
per channel
200 W
90 W
4
Ω
per channel
320 W
300 W
2
Ω
per channel
470 W
2)
400
2)
W
8
Ω
bridged
640 W
600 W
4
Ω
bridged
900 W
2)
800
2)
W
Max output voltage
8 ohms load
39 Vrms
Peak voltage, no load
63 V
Distortion etc.
THD 20Hz-20kHz
and 1W to full power
0,02 %
THD @ 1kHZ and –1dB
under clip
0,005 %
DIM 30 at –3dB under clip
0,008 %
Hum and Noise
<-105 dB
Channel separation @10kHz
70 dB
Output impedance
30 m
Ω
Slew Rate
30 V/
µ
s
Inputs
Gain, selectable
[dB]
20, 23, 26, 29,
32, 35, 38, 41
Impedance
20 kohm
Common mode rejection
50 dB
Front Panel
Gain controls
(2) channel A, B
31 positions detent
Protect indicator
(2) yellow LEDs
80
°
C at heatsink or >12kHz at full power or shorted output
Clip Indicator
(2) red LEDs
Fast peak – slow release
Signal present indicator
(2) green LEDs
-40 dB below full output
On Indicator
(2) green LEDs
DC rail voltage for channel A and B
Rear Panel
Input connectors
(2) Neutrik Combo XLR type, 3 pin & 1/4” jack
Input /Link connector
(2) 3-pin Phoenix terminal block
Output connectors
(2) Neutrik 4-pole Speakon connectors
Switches
Clip limiter A and B
On-Off (switchable)
Link-switch
Ch.A-B
Power
230 V version
115 V version
Operation voltage
130 V-265 V AC
65 V – 135 V AC
Minimum start voltage
180 V
90 V AC
Full output power at 4ohms
230 V AC
115 V AC
Peak inrush current (Soft start limited)
10 A
5 A
Current Draw @ 4ohms&230V
Quiescent power (no load)
0.5 Arms
1 Arms
1/8 of full power (-9dB)
2.3 Arms
4.6 Arms
1/3 of full power (-5dB)
3.7 Arms
7.4 Arms
At full power (0 dB) @1 kHz 1% THD
6.5 Arms
13 Arms
Net Dimensions mm (inch)
483 (19”) W x 88 (3,5”) H x 325 (12.8”) D
Shipping Dimensions mm (inch)
560 (22”) W x 180 (7.1”) H x 500 (19.7”) D
Net Weight
12.5 kg (27.5 lbs)
Shipping Weight
14.1 kg (31 lbs)
Approvals
CE
Emission
EN 55 103-1, E3
Immunity
EN 55 103-2, E3, with S/N below 1% at normal operation level
4)
Safety
EN 60 065, class I
THX
iP900T
1) Specifications measured with 230 VAC
4) Normal operation level 1/8 of full power or –9dB below clip level.
2) Component tolerance dependent
3) Continuous power, one channel driven or peak power both channels driven
(Thermal protection may occur at high continuous power)
2002-03 V1