Static electric oven (option):
Enamelled sheet metal. Dimensions L x D x H: 400 mm (15
47
/
64
’’) x 465 mm (18
19
/
64
’’) x 265 mm (10
27
/
64
’’). 3 shelf level
with 70 mm spacing, 55 liters / 1.98 ft
3
.Thermostatically controlled roof and base heating elements, safety cut-out by safety
thermostat. Electric grill 2100 W.
Rating: 2200 W– Power supply: 240 VAC 60Hz.
Ventilated electric oven (Option):
Heating provided by circular heating element surrounding a reaction fan. Dimensions L x D x H: 400 mm (15
47
/
64
’’) x 420
mm (16
17
/
32
’’) x 280 mm (11
1
/
32
’’). 3 shelf level with 70 mm spacing, 45 liters / 1.59 ft
3
Electric grill 2100 W.
Thermostatically controlled heating elements, safety cut-out by safety thermostat.
Rating: 2650 W – Power supply: 240 VAC 60Hz.
Accessories:
One shelf, a roasting pan per oven.
Shipment / Packaging:
Unpack and check the appliance is in good condition. In case damage, note any reservations on the delivery note and
confirm them within 48 hours by registered letter with confirmation of delivery to the carrier.
Appliance
Width
Depth
Height mm / ’’
Weight Gross/Net - Kg / lb
D US 10 01 5 0T U S G - -- 1130 mm / 44.5’’
760 mm / 29.9’’
1050 mm / 41.3’’ 120 kg /108 kg – 267 / 240 lb
D US 14 01 5 0T U S G - -- 1450 mm / 57.1’’
840 mm / 33.1’’
1070 mm / 42.1’’ 200 kg /180 kg – 445 / 400 lb
D US 18 01 5 0T U S G - -- 1850 mm / 72.8’’
840 mm / 33.1’’
1070 mm / 42.1’’ 275 kg /245 kg – 605 / 540 lb
Gas connection:
1/2” ID NPT (Sch 40) inlet, on male coupling (Figures 1, 1a, 1b, 1c, 1d, 2a, 2b, 2c & 2d). Sealant on all pipe joints must be
resistive to LP gas.
If used, a flex gas line for the gas supply must be metal of at least 1/2” ID NPT approved by an approved certifying agency
(A.G.A., C.G.A., etc.) in compliance with ANSI Z21.41 and Z21.69. Never use a hose made of rubber or other synthetic
material.
Gas supplying:
Appliance gas supplying can be switched, please refer to rating plate and marking at the rear of the appliance.
Electrical connection:
On terminal block at the rear of the appliance. Use flexible cord in accordance with standard N.E.C., AINSI/NEMA 70-
1996 or latest edition (not cord provided) worktop (Figures 1, 1a,1b, 1c, 1d & 2, 2a, 2b, 2c, 2d).
Pressures and hourly consumption:
Appliance gas supplying can be switched (table 1).
Table 1
PRESSURE
6’’ WC
10’’ WC
GAS
Natural Gas
L.P. Propane
Burner
Btu / hr
Btu / hr
Gas Oven
13500
11000
Top Burner 18000 (5)
18000
17000
Heating plate (C)
18000
17000
Top burner 15000
15000
13000
Top burner 11000
11000
10000
Top burner 5000
5000
5000
F
F
SF