7.7 Air conditioning (optional extra)
The boat may be fitted with air conditioning as an optional extra.
The air conditioning unit consists of two compressors located in the
starboard engine bilge. It is an ice water circulation system.
There are unit heaters in every cabin and in the saloon ceiling.
Before you start the system :
- Open the sea water circulation system (suction valve) in the
starboard engine bilge.
Check the cooling pump and circulation pump breakers and the
electronical management breakers (access in the engine bilge, under
the watermaker location) are set to "ON".
Check the breakers of the different components on the AIR
CONDITIONING bus of the 110 V - 220 V electrical panel are set to
"ON".
POWER SUPPLY
Select the supply source (Generator or shore power socket # 2 using
the AIR CONDITIONING selector on the 110 V - 220 V selection panel.
Start the air conditioning unit and set the temperature and ventilation
desired on the air conditioning controls in the areas concerned.
Please note: in case the pressure should drop, open the filling valve
located before the manometer in the starboard engine bay, so as to
have some additional pressure in the system (one bar maximum).
ON BOARD UTILITY
ON BOARD UTILITY
7
LAGOON 62O
91
Caution: this system conveys water, not glycol.
- First make sure the water unit works.
- In case the pressure should drop again and again, seek advice from
a specialist.
For the draining, use and maintenance of the air conditioning system,
refer to its instruction guide.
7.8 Icemaker (optional extra)
The boat may be fitted as an optional extra with an icemaker located
in the cockpit.
The port tank supplies it with water.
Open the fresh water valve located behind the icemaker.
Turn the switch at the bottom of the icemaker on “ON”.
Check the GALLEY breaker located on the UTILITY bus of the 110 V -
220 V electrical panel is set to "ON".
Check its breaker located on the "Household appliances" panel (see
chapter ELECTRICITY, page 63) is set to "ON".
POWER SUPPLY
Select the supply source (Inverter, Generator or shore power socket
# 1 using the UTILITY selector on the 110 V - 220 V selection panel.
For the use and maintenance of the icemaker, refer to its instruction
guide.