Laird MTTC-1410 User Manual - page 4
4
www.lairdtech.com
Laird Technologies
MTTC-1410
Temperature Controller
user
Manual
In Figure 4, red represents solidly lit digits, while blue represents a blinking digit. The value of a blinking digit can
be changed by pressing the “Up” or “Down” keys. Pressing the cycle key (“ ”) changes the position of the blink-
ing digit one step to the left.
• Selecting the setpoint temperature.
Press and hold the “Set” button for 3 seconds. The setpoint temperature will be displayed. Use the “ ”
key to select a digit, and then push either the “Up” or the “Down” key to change the value of the
blinking digit. After choosing the set point, press “Set” once more to enter the setpoint temperature.
(The “Set” button must be pressed to store the new setpoint; otherwise, the controller will revert to
the previous setpoint.)
• Changing PID terms and the calibration offset value.
Press and hold both the “Up” and “Down” buttons for 3 seconds. The Proportional band adjustment
will be displayed. Use the “Up” or “Down” keys to scroll through the selection list to select which item
is to be adjusted (Proportional band, Integral Time, Derivative Action, Calibration Offset). Press “ ” to
select the digit to be changed, and then push “Up” or “Down” key to change the value of blinking
digit. Press “Set” once more to enter the new values. (The “Set” button must be pressed to store the
new values; otherwise, the controller will revert to the previous values.)
Figure 4 - Functions Menu
Figure 3 - User Interface
ConTroller aDjusTMenT