Manual is about: SENTRY 150W CDM color changer

Summary of IP65

  • Page 1

    L l l e e e d d d p p p o o o w w w e e e r r r r r r g g g b b b i ii p p p 6 6 6 5 5 5 l l l e e e d d d p p p o o o w w w e ee r rr s ss u u u p p p p p p l ll y y y user’ s manual release 2.0 this manual must be considered an integral part of the projector..

  • Page 2

    1 before connecting and using led power rgb, it is important to read carefully all the instructions in this manual. Qualified personnel only, in compliance with all the security laws, can do the installation, the maintenance and the utilisation of this power supply. Before connecting led power rgb, ...

  • Page 3

    2 dimensions & weight = 1,9 kg technical data - ip65 protection rate - aluminium body with silicone gasket - ideal for out-door, can be installed in any position - input voltage range: from 85vac to 265vac. Frequency: 50-60 hz - 0,95 pfc electronically controlled - can drive up to 36leds (rgb) or 48...

  • Page 4

    3 installation led power rgb can be installed in any positions. Attention, the ip65 protection rate does not allow to install the unit in places that can be flooded (for example under-ground box) the base of led power rgb has 4 blind holes. Open this holes if necessary. Distance of the holes: 172x13...

  • Page 5

    4 signal cable selection use only shielded and twisted cables with eia485 (rs485) standards. The cable must be low capacity and with an impedance between 82 and 120 ohm. It is preferable not to use audio cables. The wire size we recommend is 26 awg or higher. If the projector have cable clamps, the ...

  • Page 6

    5 always, use male xlr 3 or 5 pin connector to connect the projectors to the dmx controller. Solder on pin 1 of the xlr connector the shield of the signal cable, on pin 2 solder the negative (example: black wire of cable) and on pin 3 solder the positive (example: red or white wire of the cable). Th...

  • Page 7

    6 dmx signal cable connection for fixed installation it is better to connect signal cables in/out directly to the terminal connection block with the cable going through the pg9 cable clamps. The cable’s diameter must be compatible with the cable clamps of the projector (pg9), diameter from 4 to 7mm....

  • Page 8

    7 using cable with rj45 and hub it is possible to connect a 4 couples cable to the dedicated terminal connection block (leds) and terminate it with an rj45 female plug. This way you can use utp cables with rj45 cat.5 connectors and special hub rj45 for “t” junction. The projectors are connected in s...

  • Page 9

    8 schematic menu following the list of menu and submenu..

  • Page 10

    9 user’s interface use inside display interface to modify setting of the projector: change dmx starting address, enable stand alone function. Use the buttons + and - to surf the menu’s function. To enter into the menu, you have to push the mode button and after that you can search for the desiderate...

  • Page 11

    10 - dm.St : (leds state when dmx signal isn’t received). When the board is switched on and dmx signal is missing, the board can do this functions: black-out, leds on at 15% or led on at 100%. Default value 15.On go to this submenu pushing mode , choose dm.St with + and - and push enter . Use + and ...

  • Page 12

    11 - temp : (temperature) when ntc is connected, you can see heater’s temperature in celsius degrees. The board has an automatic control over the led’s power, so the leds are always under the safety temperature. Go to this submenu pushing mode , choose temp with + and - and push enter to enter in. P...

  • Page 13

    12 channel 6: strobe this channel sets the parameters of the strobe effect. On the following table you have the dmx values, the strobe frequency (flash speed) and the strobe hold. Dmx value strobe frequency (seconds) strobe light hold (seconds) dmx value strobe frequency (seconds) strobe light hold ...

  • Page 14

    13 30 0,17 112 0,84 195 1,51 31 0,18 113 to 114 0,85 196 1,52 32 0,19 115 0,86 197 1,53 from 33 to 34 0,20 116 0,87 198 1,54 35 0,21 117 0,88 from 199 to 200 1,55 36 0,22 118 0,89 201 1,56 37 0,23 from 119 to 120 0,90 202 1,57 38 0,24 121 0,91 203 1,58 from 39 to 40 0,25 122 0,92 from 204 to 205 1,5...

  • Page 15

    14 dimmer mode, one channel: 1c channel 1: dimmer to control the dimmer of all the leds, from max power to off. Dmx value function 0 led at max power from 1 to 254 proportional light output decrease 255 led off three colours mode: 3c channel 1: green, to control the light output of the green leds, f...

  • Page 16

    15 four colours mode: 4c channel 1: green, to control the light output of the green leds, from off to the max power. Dmx value function 0 led off from 1 to 254 proportional light output increase 255 led at max power channel 2: red, to control the light output of the red leds, from off to the max pow...

  • Page 17

    16 advanced mode, 16bit colour resolution: 13c d channel 1: green, to control the light output of the green leds, from off to the max power. Dmx value function 0 led off from 1 to 254 proportional light output increase 255 led at max power channel 2: green fine, 16bit regulation of green leds dmx va...

  • Page 18

    17 17 1,16 0,15 43 0,16 0,05 18 1,04 0,14 44 0,15 0,05 19 0,92 0,14 45 0,14 0,05 20 0,80 0,14 46 0,13 0,04 21 0,76 0,13 47 0,12 0,04 22 0,72 0,13 48 0,10 0,04 23 0,68 0,12 49 0,09 0,04 24 0,64 0,12 da 50 a 54 0,08 0,04 25 0,60 0,11 da 55 a 60 0,07 0,04 26 0,56 0,10 da 61 a 65 0,07 0,03 27 0,52 0,10 ...

  • Page 19

    18 channel 12: fade speed this channel allows the users to force a fade time (from 0s to 0,5s) to the speed of the r,g,b,a,dimmer channels. This function is very helpful for use the flash button of many consolle. Dmx value function 0 no fade from 1 to 255 fade from 0s to 0,5s channel 13: frequency (...

  • Page 20: Lampo

    19 lampo lighting designers s.R.L., via portogallo 4, 46042 castel goffredo (mn), italy this information only applies to customers in the european union, according to directive 2002/96/ec of the european parliament and of the council of 27/gen/2003 on waste electrical and electronic equipment (wee) ...