    LÄmpÖÄssÄ vmi 6 – 17 lÄmpÖÄssÄ 3/2016 instructions for use, installation and maintenance.

  • Page 2: 100% Geothermal Heat

    100% geothermal heat 2 foreword we thank you for your confidence in our products and congratu- late you on making an excellent choice! You have selected a long- lasting and environmentally friendly lämpöässä geothermal heat system. We hope that you will enjoy the trouble-free heating pro- vided by l...

  • Page 3

    3 contens user manual 4 1. Safety 4 2. Geothermal heating system operation 4 2.1 lämpöässä vmi structure and operating principle 5 2.1.1. Heat collection circuit 5 2.1.2. Compressor unit 5 2.1.3. Hot water storage tank 5 2.2 Ässäcooling cooling system 6 2.3. Ässäsolar solar heating system 6 3. How t...

  • Page 4: 100% Geothermal Heat

    4 100% geothermal heat user manual 1. Safety in order to ensure trouble-free operation of the lämpöässä geothermal heating system and achieve the best efficiency, the system must be transported and installed in accordance with the manufacturer’s instruc- tions. After performance of installation work...

  • Page 5: User Manual

    5 user manual use the button in the bottom left corner to return to the home screen. Use the arrow button in the bottom right corner to return to previous screen. For instructions screen, press the ‘i’ button in the top right corner. In case of operation faults, an alarm button is displayed on the t...

  • Page 6: 100% Geothermal Heat

    6 100% geothermal heat user manual use the button in the bottom left corner to return to the home screen. Use the arrow button in the bottom right corner to return to previous screen. For instructions screen, press the ‘i’ button in the top right corner. In case of operation faults, an alarm button ...

  • Page 7: User Manual

    7 user manual use the button in the bottom left corner to return to the home screen. Use the arrow button in the bottom right corner to return to previous screen. For instructions screen, press the ‘i’ button in the top right corner. In case of operation faults, an alarm button is displayed on the t...

  • Page 8: 100% Geothermal Heat

    8 100% geothermal heat user manual use the button in the bottom left corner to return to the home screen. Use the arrow button in the bottom right corner to return to previous screen. For instructions screen, press the ‘i’ button in the top right corner. In case of operation faults, an alarm button ...

  • Page 9: User Manual

    9 user manual use the button in the bottom left corner to return to the home screen. Use the arrow button in the bottom right corner to return to previous screen. For instructions screen, press the ‘i’ button in the top right corner. In case of operation faults, an alarm button is displayed on the t...

  • Page 10: 100% Geothermal Heat

    10 100% geothermal heat user manual use the button in the bottom left corner to return to the home screen. Use the arrow button in the bottom right corner to return to previous screen. For instructions screen, press the ‘i’ button in the top right corner. In case of operation faults, an alarm button...

  • Page 11: User Manual

    11 user manual use the button in the bottom left corner to return to the home screen. Use the arrow button in the bottom right corner to return to previous screen. For instructions screen, press the ‘i’ button in the top right corner. In case of operation faults, an alarm button is displayed on the ...

  • Page 12: 100% Geothermal Heat

    12 100% geothermal heat user manual use the button in the bottom left corner to return to the home screen. Use the arrow button in the bottom right corner to return to previous screen. For instructions screen, press the ‘i’ button in the top right corner. In case of operation faults, an alarm button...

  • Page 13: User Manual

    13 user manual use the button in the bottom left corner to return to the home screen. Use the arrow button in the bottom right corner to return to previous screen. For instructions screen, press the ‘i’ button in the top right corner. In case of operation faults, an alarm button is displayed on the ...

  • Page 14: 100% Geothermal Heat

    14 100% geothermal heat user manual use the button in the bottom left corner to return to the home screen. Use the arrow button in the bottom right corner to return to previous screen. For instructions screen, press the ‘i’ button in the top right corner. In case of operation faults, an alarm button...

  • Page 15: Installer Manual

    15 4. Installation works 4.1. Before installation pipe assemblies for the installation of the lämpöässä system may only be installed by qualified and trained persons. The equipment must be installed in compliance with instructions provided; after performance of installation works, the installation c...

  • Page 16: 100% Geothermal Heat

    16 100% geothermal heat 16 installer manual 4.1.4. Space requirements a lämpöässä vmi ground source heat pump can conveniently be placed into a technical or utility room. The floor space to be reserved for the machine needs not significantly exceed its external dimensions. Approx. 50-60 cm of instal...

  • Page 17: Installer Manual

    17 17 installer manual 10. When de-aeration has been completed turn the motor protection switch qm1 off and also manual control function off. 11. Open shut-off valve (1) at the back of the group of fill valves. 12. Close both ball valves (3) and (4). 13. Remove the fill hoses. 14. Fasten the expansi...

  • Page 18: 100% Geothermal Heat

    18 100% geothermal heat 18 installer manual the storage tank is to be filled with special care through the group of fill valves included in the system so that the storage tank pressure never exceeds 1.5 bar. While filling the storage tank, the air inside it must be allowed to escape freely and not t...

  • Page 19: Installer Manual

    19 19 installer manual • the heating system has been filled and de-aerated appropriately • the ground circuit has been installed, filled and de-aerated appropriately 4.3. Electrical installation and outdoor sensors only qualified electricians are permitted to carry out electrical work on the heat pu...

  • Page 20: 100% Geothermal Heat

    20 100% geothermal heat 20 installer manual • external supply is connected to terminals a1 and a2. • terminals 15 and 16 are connected to geothermal heat pump and interrupt the heating element’s supply with respect to the phase the current value of which is exceeded. • each phase must be lead throug...

  • Page 21: Maintenance Manual

    21 maintenance manual 5. Maintenance 5.1. Maintenance and care the lämpöässä ground source heat pump is an easy-care and reliable heating system that does not require regular maintenance. If the installa- tion is carried out with care and in accordance with the instructions pro- vided, there is usua...

  • Page 22: 100% Geothermal Heat

    22 100% geothermal heat 22 maintenance manual use the button in the bottom left corner to return to the home screen. Use the arrow button in the bottom right corner to return to previous screen. For instructions screen, press the ‘i’ button in the top right corner. In case of operation faults, an al...

  • Page 23: Maintenance Manual

    23 23 maintenance manual use the button in the bottom left corner to return to the home screen. Use the arrow button in the bottom right corner to return to previous screen. For instructions screen, press the ‘i’ button in the top right corner. In case of operation faults, an alarm button is display...

  • Page 24: 100% Geothermal Heat

    24 100% geothermal heat 24 maintenance manual use the button in the bottom left corner to return to the home screen. Use the arrow button in the bottom right corner to return to previous screen. For instructions screen, press the ‘i’ button in the top right corner. In case of operation faults, an al...

  • Page 25: Maintenance Manual

    25 25 maintenance manual use the button in the bottom left corner to return to the home screen. Use the arrow button in the bottom right corner to return to previous screen. For instructions screen, press the ‘i’ button in the top right corner. In case of operation faults, an alarm button is display...

  • Page 26: 100% Geothermal Heat

    26 100% geothermal heat 26 maintenance manual use the button in the bottom left corner to return to the home screen. Use the arrow button in the bottom right corner to return to previous screen. For instructions screen, press the ‘i’ button in the top right corner. In case of operation faults, an al...

  • Page 27: Maintenance Manual

    27 27 maintenance manual use the button in the bottom left corner to return to the home screen. Use the arrow button in the bottom right corner to return to previous screen. For instructions screen, press the ‘i’ button in the top right corner. In case of operation faults, an alarm button is display...

  • Page 28: 100% Geothermal Heat

    28 100% geothermal heat 28 6. Warranty conditions the manufacturer grants its products a two (2) year warranty from the commissioning date specified in the product’s warranty certificate. During the warranty period, the manufacturer is responsible for that the product complies with its agreed charac...

  • Page 29: Technical Specifications

    29 technical specifications 7. Technical specifications lÄmpÖÄssÄ vmi 6 vmi 9 vmi 11 vmi 11 1x230 vmi 14 vmi 14 1x230 vmi 17 width mm 1020 1020 1020 1020 1020 1020 1020 depth mm 700 700 700 700 700 700 700 height mm 1830 1830 1830 1830 1830 1830 1830 weight kg 422 426 440 440 450 450 458 heat pump t...

  • Page 30: 100% Geothermal Heat

    100% geothermal heat 30 technical specifications electrics: vmi 6 vmi 9 vmi 11 vmi 11 1x230 vmi 14 vmi 14 1x230 vmi 17 power supply 400v 3n~ 50hz 400v 3n~ 50hz 400v 3n~ 50hz 230v 1n~ 50hz 400v 3n~ 50hz 230v 1n~ 50hz 400v 3n~ 50hz starting current a 17 23 32 48 35 32 43 running curren (35 ⁰c/55⁰c) (2...

  • Page 31

    Xl 2015 811/2013 a ++ a a b c d e f g a ++ a + a b c d e f g vmi 6 38 db 00 db 8 kw 8 kw 8 kw.

  • Page 32: +++

    A +++ a + a a ++ a +++ a ++ a + a b c d e f g a +++ a ++ a + a b c d e f g + + + + xl 2015 811/2013 xl x vmi 6.

  • Page 33: 100% Geothermal Heat

    100% geothermal heat www.Lampoassa.Fi product description name or trademark lämpöässä model vmi 6 seasonal space heating application average water heating load profile xl seasonal space heating energy efficiency class a ++ water heating energy efficiency class a rated heat output under average clima...

  • Page 34: 100% Geothermal Heat

    100% geothermal heat www.Lampoassa.Fi declared capacity for heating at indoor conditions 20°c and outdoor temperature tj heating average tj = -7 °c 7,8 kw 3,42 copd tj = 2 °c 8,0 kw 3,97 copd tj = 7 °c 8,1 kw 4,33 copd tj = 12 °c 8,3 kw 4,61 copd tj = bivalent temperaturea 7,8 kw 3,30 copd tj = oper...

  • Page 35

    Xl 2015 811/2013 a ++ a a b c d e f g a ++ a + a b c d e f g vmi 9 41 db 00 db 10 kw 10 kw 10 kw.

  • Page 36: +++

    A +++ a + a a ++ a +++ a ++ a + a b c d e f g a +++ a ++ a + a b c d e f g + + + + xl 2015 811/2013 xl x vmi 9.

  • Page 37: 100% Geothermal Heat

    100% geothermal heat www.Lampoassa.Fi product description name or trademark lämpöässä model vmi 9 seasonal space heating application average water heating load profile xl seasonal space heating energy efficiency class a ++ water heating energy efficiency class a rated heat output under average clima...

  • Page 38: 100% Geothermal Heat

    100% geothermal heat www.Lampoassa.Fi declared capacity for heating at indoor conditions 20°c and outdoor temperature tj heating average tj = -7 °c 9,9 kw 3,32 copd tj = 2 °c 10,0 kw 3,88 copd tj = 7 °c 10,2 kw 4,28 copd tj = 12 °c 10,4 kw 4,64 copd tj = bivalent temperaturea 9,8 kw 3,10 copd tj = o...

  • Page 39

    Xl 2015 811/2013 a ++ a a b c d e f g a ++ a + a b c d e f g vmi 11 36 db 00 db 11 kw 11 kw 11 kw.

  • Page 40: +++

    A +++ a + a a ++ a +++ a ++ a + a b c d e f g a +++ a ++ a + a b c d e f g + + + + xl 2015 811/2013 xl x vmi 11.

  • Page 41: 100% Geothermal Heat

    100% geothermal heat www.Lampoassa.Fi product description name or trademark lämpöässä model vmi 11 seasonal space heating application average water heating load profile xl seasonal space heating energy efficiency class a ++ water heating energy efficiency class a rated heat output under average clim...

  • Page 42: 100% Geothermal Heat

    100% geothermal heat www.Lampoassa.Fi declared capacity for heating at indoor conditions 20°c and outdoor temperature tj heating average tj = -7 °c 11,6 kw 3,45 copd tj = 2 °c 11,8 kw 4,02 copd tj = 7 °c 12,0 kw 4,41 copd tj = 12 °c 12,3 kw 4,80 copd tj = bivalent temperaturea 11,5 kw 3,33 copd tj =...

  • Page 43

    Xl 2015 811/2013 a ++ a a b c d e f g a ++ a + a b c d e f g vmi 11 1x230v 41 db 00 db 11 kw 11 kw 11 kw.

  • Page 44: +++

    A +++ a + a a ++ a +++ a ++ a + a b c d e f g a +++ a ++ a + a b c d e f g + + + + xl 2015 811/2013 xl x vmi 11 1x230v.

  • Page 45: 100% Geothermal Heat

    100% geothermal heat www.Lampoassa.Fi product description name or trademark lämpöässä model vmi 11 1x230v seasonal space heating application average water heating load profile xl seasonal space heating energy efficiency class a ++ water heating energy efficiency class a rated heat output under avera...

  • Page 46: 100% Geothermal Heat

    100% geothermal heat www.Lampoassa.Fi declared capacity for heating at indoor conditions 20°c and outdoor temperature tj heating average tj = -7 °c 11,3 kw 3,26 copd tj = 2 °c 11,6 kw 3,82 copd tj = 7 °c 11,8 kw 4,25 copd tj = 12 °c 12,2 kw 4,62 copd tj = bivalent temperaturea 11,2 kw 3,11 copd tj =...

  • Page 47

    Xl 2015 811/2013 a ++ a a b c d e f g a ++ a + a b c d e f g vmi 14 38 db 00 db 14 kw 14 kw 14 kw.

  • Page 48: +++

    A +++ a + a a ++ a +++ a ++ a + a b c d e f g a +++ a ++ a + a b c d e f g + + + + xl 2015 811/2013 xl x vmi 14.

  • Page 49: 100% Geothermal Heat

    100% geothermal heat www.Lampoassa.Fi product description name or trademark lämpöässä model vmi 14 seasonal space heating application average water heating load profile xl seasonal space heating energy efficiency class a ++ water heating energy efficiency class a rated heat output under average clim...

  • Page 50: 100% Geothermal Heat

    100% geothermal heat www.Lampoassa.Fi declared capacity for heating at indoor conditions 20°c and outdoor temperature tj heating average tj = -7 °c 14,6 kw 3,50 copd tj = 2 °c 14,8 kw 4,02 copd tj = 7 °c 15,0 kw 4,42 copd tj = 12 °c 15,4 kw 4,82 copd tj = bivalent temperaturea 14,5 kw 3,33 copd tj =...

  • Page 51

    Xl 2015 811/2013 a ++ a a b c d e f g a ++ a + a b c d e f g vmi 14 1x230v 43 db 00 db 14 kw 14 kw 14 kw.

  • Page 52: Vmi 14 1X230V

    A ++ a + a a ++ a +++ a ++ a + a b c d e f g a +++ a ++ a + a b c d e f g + + + + xl 2015 811/2013 xl x vmi 14 1x230v.

  • Page 53: 100% Geothermal Heat

    100% geothermal heat www.Lampoassa.Fi product description name or trademark lämpöässä model vmi 14 1x230v seasonal space heating application average water heating load profile xl seasonal space heating energy efficiency class a ++ water heating energy efficiency class a rated heat output under avera...

  • Page 54: 100% Geothermal Heat

    100% geothermal heat www.Lampoassa.Fi declared capacity for heating at indoor conditions 20°c and outdoor temperature tj heating average tj = -7 °c 13,7 kw 3,11 copd tj = 2 °c 14,0 kw 3,77 copd tj = 7 °c 14,2 kw 4,01 copd tj = 12 °c 14,5 kw 4,36 copd tj = bivalent temperaturea 13,7 kw 2,95 copd tj =...

  • Page 55

    Xl 2015 811/2013 a ++ a a b c d e f g a ++ a + a b c d e f g vmi 17 42 db 00 db 17 kw 17 kw 17 kw.

  • Page 56: +++

    A +++ a + a a ++ a +++ a ++ a + a b c d e f g a +++ a ++ a + a b c d e f g + + + + xl 2015 811/2013 xl x vmi 17.

  • Page 57: 100% Geothermal Heat

    100% geothermal heat www.Lampoassa.Fi product description name or trademark lämpöässä model vmi 17 seasonal space heating application average water heating load profile xl seasonal space heating energy efficiency class a ++ water heating energy efficiency class a rated heat output under average clim...

  • Page 58: 100% Geothermal Heat

    100% geothermal heat www.Lampoassa.Fi declared capacity for heating at indoor conditions 20°c and outdoor temperature tj heating average tj = -7 °c 16,8 kw 3,41 copd tj = 2 °c 16,9 kw 3,96 copd tj = 7 °c 17,3 kw 4,36 copd tj = 12 °c 17,6 kw 4,75 copd tj = bivalent temperaturea 16,7 kw 3,25 copd tj =...

  • Page 59

    Current monitoring relay installations and connection these settings are initial and may require changing. Relays must always be adjusted in a case-specific manner. 1. Choose correct current range • turn switch 2 to position on (if master fuse size is less than 50 a) • other switches 1, 3-6 to posit...