Landa PGHW4-3000 Operator's Manual - Operation Instructions
8.916-485.0 • LANDA PGHW • REV. 5/12
OPERA
TOR’S MANU
AL
PRESSURE
W
ASHER
8
SenDEC
TACH/H
OU
R
1/10
8916485-14
OPERATION INSTRUCTIONS
STEP 4: With the spray nozzle
pointed away from you or anybody
else, press the trigger on the spray
gun to obtain pressurized cold water
spray.
STEP 6: Selection of high or low pressure is accompanied by turning the
handle.
NOTE: High pressure nozzle must be inserted at end of wand
to obtain high pressure. Variable pressure control wand handle must be
turned clockwise to enable water to flow out of the high pressure nozzle.
To apply detergent, place detergent pick-up tube into a container of
detergent and turn the detergent valve counterclockwise.
8916485-2
Variable Pressure
Control Handle
Trigger
Variable Pressure
Wand (VP)
High
Pressure
Nozzle
Brass Soap
Nozzle
STEP 5: For hot water, turn the
burner switch to ON when a steady
stream of water flows out of the
spray gun. Burner will now light
automatically.
NOTE: Do not start
machine with burner switch on.
8916485-3
SenDE
C
TACH/
HOUR
1/10
8916485-15
Burner
Switch
Detergent
Valve
STEP 2: Read engine manual provided and
pull choke. Pull spray gun trigger to relieve
pressure. Turn the engine switch to the START
position and hold it there until the engine
starts.
NOTE: Do not engage the electric
starter for more than five seconds at a
time. If the engine fails to start, release
the switch, pull spray gun trigger and wait
ten seconds before operating the starter
again. When the engine starts, allow the
engine switch to return to the ON position.
Push the choke in.
8916485-6
Engine
Switch
STEP 3: Pull wand coupler
collar back and insert de-
sired pressure nozzle into
wand coupler. Then secure
by pushing coupler collar
forward.
CAUTION: Never
replace nozzles without
engaging the safety latch
on the spray gun trigger.
STEP 1: Read safety, installation
and preventative maintenance
i n s t r u c t i o n s b e fo r e s t a r t i n g
machine. Connect the water supply
hose to the float tank inlet swivel
connector and turn on water supply.
NOTE: Before installing pres-
sure nozzle in wand coupler, run
machine allowing water to flush
through the system until clear.
2
1
1
8916485-33