Laney LA30C User Manual - page 4
Laney
6. Chorus:
2. Tape/CD input:
3. Gain:
5. Volume:
4. Guitar Inputs:
7. Bass:
8. Paramid-
Frequency:
9. Paramid-Level:
10. Treble:
11. Reverb:
12. Insert:
The input socket has been designed to accept both balanced and unbalanced signals from
microphones with an XLR input connector. Good quality low impedance condensor or dynamic
mics should preferably be used for best results, these will ensure the best possible results from
hand-held instruments or closely mic'd instruments.
Phono (RCA) sockets are provided for the connection of tape/CD machines.
Controls the overall signal level of the mic and the tape/CD auxiliary inputs.
Active and Passive/Active inputs are provided for connection of guitars. Guitars with active
circuitry should be connected via the Active socket. Non-active guitars should be connected using
the Passive input. Incidentally, guitars with active circuitry could be placed in the Passive input if
pre-amp overloading is desired.
Controls the overall listening volume of the guitar inputs.
Enables the onboard chorus.
Active Bass control allowing boost and cut of the low-frequency response of the pre-amplifier.
Selects the frequency at which the cut or boost selected by the paramid level control (9) acts; to
access LO mid frequencies turn the frequency control anti-clockwise, to access HI mid
frequencies turn the frequency control clockwise.
Sets the level of boost or cut applied to the frequency set by control 8: for frequency boost, turn
the control clockwise; for frequency cut, turn the frequency control anti-clockwise.
Active Treble control allowing boost or cut of the high frequency response of the of the pre-
amplifier.
Controls the level of reverb on the channel.
Socket provided for accepting the signal from another amplifier, see 13
Socket provided for sending signal to another amplifier or mixing desk. Connecting an LA30C to
another non chorus amp, such as an LA30 via the Line out socket to an insert socket will produce a
dramatic stereo chorus effect between the two amplifiers.
(Always switch off and
disconnect the power cord when not in use).
This fuse protects the AC power of the overall amplifier. Use only the correct size and rating.
Main power switch, the led will be lit when the amplifier is switched on.
13. Line Out:
1. Mic Input:
LA30C front panel
Chorus
Insert
Line Out
Acoustic Amplifier
Power
0
1
7
7
1
1
9
9
3
3
10
10
4
4
6
6
0
0
5
5
8
8
2
2
7
7
1
1
9
9
3
3
10
10
4
4
6
6
0
0
5
5
8
8
2
2
LA30C
CD In
Mic
Gain
1
7
7
1
1
9
9
3
3
10
10
4
4
6
6
0
0
5
5
8
8
2
2
7
7
1
1
9
9
3
3
10
10
4
4
6
6
0
0
5
5
8
8
2
2
Passive
Active
Instrument
Volume
2
Bass
Treble
Reverb
7
7
1
1
9
9
3
3
10
10
4
4
6
6
0
0
5
5
8
8
2
2
7
7
1
1
9
9
3
3
10
10
4
4
6
6
0
0
5
5
8
8
2
2
2
2
4
4
4
4
2
2
5
5
1
1
1
1
5
5
- 0+
- 0+
3
3
3
3
2
2
4
4
4
4
2
2
5
5
1
1
1
1
5
5
- 0+
- 0+
3
3
3
3
Paramid
Freq
Level
Anti-Feedback
1K
1K
100
100
500
500
2
2
4
4
4
4
2
2
5
5
1
1
1
1
5
5
- 0+
- 0+
3
3
3
3
11
22
33
44
11
55
66
77
88
99
10
10
11
11
12
12
13
13
14
14
W
ARNING
- T
HIS
EQUIPMENT
MUST
BE
EARTHED
.
W
ARNING
- T
HIS
EQUIPMENT
MUST
BE
EARTHED
.
W
ARNING
- T
O
REDUCE
THE
RISK
OF
FIRE
OR
ELECTRIC
SHOCK
DO
NOT
EXPOSE
THIS
APPLIANCE
TO
RAIN
OR
MOISTURE
.
W
ARNING
- T
O
REDUCE
THE
RISK
OF
FIRE
OR
ELECTRIC
SHOCK
DO
NOT
EXPOSE
THIS
APPLIANCE
TO
RAIN
OR
MOISTURE
.
C
AUTION
- T
O
REDUCE
THE
RISK
OF
ELECTRIC
SHOCK
DO
NOT
REMOVE
COVERS
.N
O
USER
SERVICEABLE
PARTS
INSIDE
. R
EFER
SERVICING
TO
QUALIFIED
PERSONNEL
ONLY
.
C
AUTION
- T
O
REDUCE
THE
RISK
OF
ELECTRIC
SHOCK
DO
NOT
REMOVE
COVERS
.N
O
USER
SERVICEABLE
PARTS
INSIDE
. R
EFER
SERVICING
TO
QUALIFIED
PERSONNEL
ONLY
.
A
TTENTION
- R
EMPLACER
LE
FUSIBLE
SEULEMENT
PAR
LE
MEME
TYPE
ET
LE
MEME
CALIBRE
.
A
TTENTION
- R
EMPLACER
LE
FUSIBLE
SEULEMENT
PAR
LE
MEME
TYPE
ET
LE
MEME
CALIBRE
.
A
TTENTION
- D
EBRANCHER
LE
CORDON
D
’
ALIMENTATION
AVANT
TOUTE
INTERVENTION
.
A
TTENTION
- D
EBRANCHER
LE
CORDON
D
’
ALIMENTATION
AVANT
TOUTE
INTERVENTION
.
A
VIS
- R
ISQUE
DE
CHOC
ELECTRIQUE
-
NE
PAS
OUVRIR
.
A
VIS
- R
ISQUE
DE
CHOC
ELECTRIQUE
-
NE
PAS
OUVRIR
.
C
AUTION
- F
OR
CONTINUED
PROTECTION
AGAINST
RISK
OF
FIRE
REPLACE
ONLY
WITH
SAME
TYPE
AND
RATED
FUSE
.
C
AUTION
- F
OR
CONTINUED
PROTECTION
AGAINST
RISK
OF
FIRE
REPLACE
ONLY
WITH
SAME
TYPE
AND
RATED
FUSE
.
M
ADE
I
N
C
HINA
M
ADE
I
N
C
HINA
F
ABRIQUE
E
N
C
HINE
F
ABRIQUE
E
N
C
HINE
N15039
N15039
www.laney.co.uk
Laney
P O W E R TO T H E M U S I C
P O W E R TO T H E M U S I C
!!
CAUTION
RISK OF ELECTRIC SHOCK DO NOT OPEN
P
OWER
C
ONSUMPTION
50 W
ATTS
~50/60H
Z
P
OWER
C
ONSUMPTION
50 W
ATTS
~50/60H
Z
~100VA
C 50/60H
Z
~100VA
C 50/60H
Z
P
OWER
S
OURCE
P
OWER
S
OURCE
~230V A
C 50/60H
Z
~230V A
C 50/60H
Z
~120VA
C 50/60H
Z
~120VA
C 50/60H
Z
T500
M
A L / 125V
T500
M
A L / 125V
~240V A
C 50/60H
Z
~240V A
C 50/60H
Z
T250
M
A L / 250V
T250
M
A L / 250V
S
ERIAL
N
UMBER
S
ERIAL
N
UMBER
D
ESIGNED
IN
THE
UK
BY
L
ANEY
D
ESIGNED
IN
THE
UK
BY
L
ANEY
M
ODEL
M
ODEL
LA30C
LA30C
ABC- 1 2 3 4 5 4 6 7 8 9 0 - 1 2 3 4 5 6 7 8 9
15
15
14. Power Switch:
15. Power Fuse:
3
ACOUSTIC
LA30C rear panel