Larius 2 Operating And Maintenance Instructions Manual - Cleaning After The
9
LARIUS 2 - painting
English
H6
H2
H1
H3
H4
H5
SPRAY ADJUSTMENT
•
Slowly turn the knob on the flow regulator clockwise, until
a pressure is obtained that guarantees good atomisation of
the product.
•
An irregular and marked spray on the sides indicates a low
working pressure. On the contrary, a too high pressure causes
a high fog (“overspray”) and waste of product.
•
In order to avoid overthickness of paint, let the gun advance
sideways (right-left) when spraying.
H
CLEANING AFTER THE
SPRAY PAINTING OR IN
CASE OF PRODUCT CHANGE
•
Reduce product pressure to the minimum (0,5-1 bar) by
means of knob (
H1).
•
Use knob (
H2) to set the air atomisation knob to zero.
•
Disconnect the return hose (
H4) from tank (H3) and introduce
it into an empty can for recuperating the product.
•
Open the recycling tap (
H5) and let the pump work until the
tank and the pump itself have been emptied.
•
Close the recycling tap (
H5).
•
Put back the recycling hose (
H4) into the tank (H3).
•
Pour some solvent in the tank (
H3).
•
Open the recycling tap (
H5), set the product pressure at the
minimum value by means of the knob (
H1).
•
The pump will be set to work. Let the solvent recycle for a
short time and then close the recycling tap (
H5).
•
Unscrew the atomizing head (
H6) and rinse it with the solvent,
put it back and by means of the spray gun discharge in a tank
the product left until the solvent comes out.
•
Always paint with regular parallel bands coats.
•
Keep a safety and constant distance between the gun and the
support to be painted and also keep yourselves perpendicular
to it.
NEVER point the spray gun at yourselves or at
other people. The contact with the casting can
use serious injuries. In case of injuries caused by
the gun casting, seek immediate medical advice
specifying the type of the product injected.