    Instruction manual doc no a340-d05-v22-q2 03/12 inverter with energy meter.

  • Page 2

    Welcome latronics latronics latronics latronics products are all proudly designed, engineered and manufactured in australia. As a specialist sine wave inverter company we produce inverters for a diverse range of applications such as; mining, railways, telecommunications, marine, remote power, motor ...

  • Page 3

    Table of contents page installation dc wiring / dc earthing wiring diagrams special features dip switch settings inverter operation solar input configuration fault finding radio frequency interference warranty conditions technical specifications 18 17 16 15 14 13 12 10 7 3 2 ac wiring 5 declaration ...

  • Page 4

    Declaration of conformity manufacturer: latronic sunpower pty ltd 105 grigor st west moffat beach industrial park caloundra queensland 4551 australia declare that the pv edge grid connected inverter model no. Pve1200 and pve2500 conform to the requirements of following standards en61000-6-1 en61000-...

  • Page 5

    3 dc wiring check solar array will not exceed inverter’s maximum voltage rating of 103v (pve1200) or 206v (pve2500) if other sources of dc input are required e.G. Wind turbines, micro hydro turbines etc. A battery bank or latronics turbine controller (see pg 9) will be required with the maximum powe...

  • Page 6

    Sbs50 connector wiring the inverter comes with an sbs50 connector panel mounted on the case. To assemble the connecting partner, take the sbs50 connector and follow the instructions below. 1. Remove the lugs with a screwdriver from the plug by inserting into the end and pressing down on the thin met...

  • Page 7

    Ac wiring both models require an external circuit breaker for protection of inverter’s ac input. Usually mounted in main switchboard and/or next to the inverter. The active and neutral of the ac output are electrically isolated from the dc inputs and earth connections. Latronics inverters have the a...

  • Page 8

    6. Connect the active, neutral and earth cables as per diagram below. 7. Push the socket back into the main body until it clips in. 8. Screw the pressure ring back in to form a tight seal. 9. Plug into pv edge. To disconnect the plug, simply push the release clip in and unplug. Note: the release cli...

  • Page 9

    7 batteryback-upsystem 10a legend pv edge lsinverter solarpanels ac t ransferswitch (acts -2) regulator (optional) switchboard power power lights lights hot w ater s tove aircon (exampleonly) pve1200 – 48v (min200ahrs) pve2500 – 96v (min200ahrs) batteries =circuitbreaker ac dc 10a exportmeter import...

  • Page 10

    8 s tandardgridconnectsystem w arning: theinverteroutputisconnectedtomainselectricity ,thusitisimport antthatall acwiringcomplies withtherequirement softherelevantwiringst andards,(as3000, as4777). Anyworkcarriedouton ac/mainswiringistobeperformedbyqualified andlicensed personnelonly . Solarpanels g...

  • Page 11

    12 special features digital energy display night time disconnect parallel operation note: maximum power point tracking protection maintenance cycle the backlit energy display shows instantaneous power, accumulative power, ac voltage, ac current, ac power factor and ac frequency. See page 14 for more...

  • Page 12

    10 11 dc solar connector for easy connection and disconnection of dc input power from solar panels or battery bank. Fan if the temperature inside the inverter reaches preset levels, the variable speed fan will switch on initially in low speed and then into higher speed if the temperature continues t...