Latronics PVE1200 Instruction Manual - page 10
8
S
tandardGridConnectSystem
W
ARNING:
TheInverteroutputisconnectedtomainselectricity
,thusitisimport
antthatall
ACwiringcomplies
withtherequirement
softherelevantwiringst
andards,(AS3000,
AS4777).
Anyworkcarriedouton
AC/MainswiringistobeperformedbyQualified
AndLicensed
personnelonly
.
SolarPanels
GridMains
Switchboard
Power
Power
Lights
Lights
Hot
W
ater
S
tove
AirCon
(Exampleonly)
10A
Legend
=CircuitBreaker
ExportMeter
Import
Meter
DIP SWITCH SETTINGS
Switch 1 -MPPT / Battery mode
Switch 2 - 50/60 Hz
Switch 4
Switch 5
Switch 6
In the ON position
the Maximum Power Point Tracking is enabled.
This is required when the DC input is Photovoltaic Solar Modules only.
In the OFF position the Maximum Power Point Tracking is disabled and the
voltage tracking will operate at a fixed voltage of 54V (PVE1200) or 108V
(PVE2500). This setting is required in a system where a 48V (PVE1200) or
96V (PVE2500) Battery Bank is required on the DC input.
In the ON position the Inverter is set for 60Hz operation.
In the OFF position
the Inverter is set for 50Hz operation.
Must be in OFF position
for normal operation. The ON position is a
factory AC test setting.
Must be in the OFF position
for normal operation. The ON position
is a factory DC test setting.
Not used.
(default)
(default)
(If Switch 1 OFF)
(If Switch 1 ON)
(Default)
(default)
(default)
Switch 3
ON = Gel/SLA battery.
ON = 255VAC sustained operation
OFF = Flooded battery.
OFF= Sustained operation turned off
13
DIP SWITCH LOCATION
MAIN PCB
DIP Switch located on Main PCB
1 2 3 4 5 6
OFF
ON
WARNING:
Due to dangerous voltages existing inside the unit, make sure
the external DC and AC solar isolators are turned off before
opening the unit. Only
are permitted to
adjust these settings.
qualified Trades Persons
PV
Edge