Lavry AD11 Manual - page 20
AD11
Specifications
16
XLR Unbalanced input:
With gain set to 6 dB
+18dBu
With gain set to 12 dB +12dBu
¼” input Balanced or Unbalanced:
With gain set to 0 dB
+11dBu (+8.8dBV)
With gain set to 12 dB - 1dBu ( -3.2dBV)
Input connections Line Level:
XLR
- Balanced analog: Pin 2 non-inverting, Pin 3 Inverting. Pin 1 shield
- Unbalanced analog: Pin 2 non-inverting, Pin 3 signal return, Pin 1 shield
¼”
- Balanced analog TRS: Tip non-inverting, Ring inverting, Sleeve shield
- Unbalanced analog TS: Tip non-inverting, Sleeve signal return and shield
Input connections for Low Impedance Balanced Microphone (uses same XLR inputs as Line Level):
Transformer-
free electronically balanced Pin 2 “+” XLR inputs.
Phantom Power- +48 volts Phantom power for condenser microphones, can be enabled or disabled
for each input channel individually using front panel setting. Automatically disabled for Gain settings
less than 20dB.
External Clock Input: BNC- Accepts either Word Clock or AES/SPDIF sync. Fixed internal 75 Ohm
termination.
External Clock Output: BNC-
Sample period “TTL” level Word Clock signal at the output SF. The
connection must have one 75 Ohm termination at the receiver.
Digital Output Connections:
XLR- Connect to AES inputs using standard 110 ohm XLR to XLR cables. Connect to coaxial SPDIF
inputs using XLR to RCA adapter or adapter cable. Output format set by front panel setting to either
AES or
“SPDIF” (IEC 60958 type II Consumer format). Output is always 24 bit Wordlength.
RCA- Connect to SPDIF/RCA inputs using standard 75 ohm RCA to RCA cables. Connect to XLR
inputs using RCA to XLR adapter or adapter cable. Output format set by front panel setting to either
AES or
“SPDIF” (IEC 60958 type II Consumer format). Output is always 24 bit Wordlength.
USB- Connects to computer using standard USB cable. Requires USB 2.0 or above.
AC Power:
Voltage 90-264 VAC, Frequency 40-63Hz,
Typical Current usage: 0.1A
Fuse Rating 2.5A
“Time Delay” *
*Subject to change! Please always check the rating on the fuse and the one printed next to the fuse
holder on the power supply PC board before replacement. Replace the fuse ONLY with a fuse of the
same rating. If you have any questions, contact:
techsupport@lavryengineering.com
Please Note: The AD11 automatically adjusts to AC power inputs in the range of 90 to 264 Volts AC
and line frequencies between 47 and 63 Hertz. There are no settings to change.
Dimensions and Weight:
8
”w x 1.75”h x 10.75” d (including front panel switches and rear panel connectors)
Optional Rack Mount Kit: An optional Rack Mount Kit is available which can be used to mount any
combination of two LavryBlack units in a 1U 19” rack space. Please note that this kit cannot be used
to rack mount a
single
LavryBlack unit.