Lavry DA10 User Manual

Other manuals for DA10: Manual
Manual is about: Digital to Analog Converter

Summary of DA10

  • Page 1

    Lavryblack series model da10 digital to analog converter lavry engineering, inc. P.O. Box 4602 rolling bay, wa 98061 http://lavryengineering.Com email: techsupport@lavryengineering.Com rev 3.52 august 6, 2009.

  • Page 4

    Lavryblack da10 operation 1 model da10 the lavryblack da10 features: - ultra low jitter modes. - included sample rate conversion for non-standard rates. - potentiometer-free digitally controlled analog volume circuitry. - high power discrete headphone output. - xlr, coaxial (rca) and optical (toslin...

  • Page 5

    Lavryblack da10 operation 2 cd’s may need to have the output format changed to “stereo” before the da10 can reproduce the audio on a cd. Some computer interfaces have optical outputs that can be set to “adat” which is multi channel, and is not compatible with the stereo digital input of the da10. Co...

  • Page 6

    Lavryblack da10 operation 3 - when the pll mode is set to narrow or crystal and the da10 receives a valid input signal, both the “lock” lamp and the sample rate indicator that corresponds to the input’s sample frequency illuminate. The input must have a sample frequency of 44.1, 48, 88.2, or 96 khz....

  • Page 7

    Lavryblack da10 operation 4 the polarity setting is provided for two reasons: 1. To provide flexibility with output connection wiring. 2. To allow the signal polarity to be corrected when it is inverted due to polarity inversion in the recorded music or other equipment/wiring in your system. - pleas...

  • Page 8

    Lavryblack da10 operation 5 2.) connect the main output of the da10 directly to the input of a power amp or powered monitors and use the volume control of the da10 to adjust the speaker volume. Please note: when operating the da10 connected directly to a power amp or powered monitors, it is importan...

  • Page 9

    Lavryblack da10 operation 6 volume setting xlr balanced operation xlr unbalanced operation headphone level 56 24dbu 18dbu 18dbu 50 18dbu 12dbu 12dbu --- --- --- --- 46 14dbu 8dbu 8dbu --- --- --- --- 01 -31dbu -37dbu -37dbu 00 off off off aes/ebu professional analog line levels: set to 56 for 24dbu ...

  • Page 10

    Lavryblack da10 operation 7 if you have difficulty determining the correct setting, please contact techsupport@lavryengineering.Com once you have the manufacturer’s ratings for your equipment. G. Setting the da10’s internal jumpers the internal jumpers must be configured to match the wiring of the c...

  • Page 11

    Lavryblack da10 operation 8 to set the jumpers for “pin 3 hot unbalanced” operation: 11.) the jumpers that need to move are the ones labeled: “hot, pin 2, & ground.” pull the small rectangular black plastic jumper straight “up” and off of the two pins it is on and re-position it to slide back down o...

  • Page 12

    Lavryblack da10 specifications 9 specifications: thd+n at max volume (volume = 56) – typical, 0.0008% fs, maximum 0.0013% fs test conditions: 20hz – 20khz, -3dbfs sine wave, 22-22khz bw at all possible settings and switch combinations. Dynamic range: -110db typical, -109 db minimum test conditions: ...

  • Page 13

    Lavryblack da10 warranty 10 l i m i t e d w a r r a n t y – l a v r y b l a c k s e r i e s m o d e l d a 1 0 subject to the conditions set forth below, for one year after the original purchase date of the product, lavry engineering will repair the product free of charge in the united states in the ...