Lavry DA2002 Operation Manual - Input Signal Selection
DA2002
Operation
5
PART I: Operating Instructions
Operation of the
Model DA2002 Digital to Analog Converter
requires the use of two push
button switches located on the front panel:
POLARITY
inverts the absolute polarity of the signal.
INPUT SELECT
controls selection of digital inputs to the DAC.
Input Signal Selection
Selecting the Digital Input
-The INPUT SELECT lamps indicate which input signal is
selected. Pressing the INPUT SELECT push button selects the next input position.
Search Mode/ Manual Mode
- Holding the INPUT SELECT button for more then one
second toggles the INPUT SELECT between Search Mode and Manual Mode. The mode
selected is retained when power is removed.
In
Search Mode
, each time the INPUT SELECT button is pressed, the DA2002 will
“scan” the inputs for the next input with a valid signal present. It will skip the inactive
input connectors (where no signal is present). The default setting is Search Mode enabled.
In
Manual Mode
, each press of the INPUT SELECT button moves the selection to the
next position. It will not skip inactive inputs.
Input Signal Connection
The unit can be connected to one, two, or three digital input connectors located on the rear panel:
AES/EBU input to the XLR connector designated as
AES INPUT 1
AES/EBU input to the XLR connector designated as
AES INPUT 2
SPDIF (consumer format) input to the connector designated as
IEC INPUT