Lay-Z-Spa 54112 Vegas Owner's Manual - page 4
Zone 2
Zone 1
Zone 0
Zone 0
Zone 2
2.5m
2.5m
1.5m
1.5m
2m
2m
h
h
WARNING:
RISK OF ELECTRIC SHOCK. The pump must be
tested before each use.
WARNING:
Insert the plug into a residual current device (RCD) protected power outlet only.
WARNING:
Before inserting plug into a power outlet, make sure the current rate of the power outlet is suitable for the pump.
WARNING:
Do not use the pump if this test fails.
1.
Insert the plug into a mains socket. The LED
automatically displays the current water
temperature.
2.
Press the “Test” button. All the indicator lights turn
off, and the pump beeps out a warning.
3.
Unplug and then plug the pump back in to start the
system. The pump is ready to use.
IM
P
O
R
TA
N
T
N
O
T
IC
E
T
hi
s
un
it
wi
ll a
uto
lo
cko
ut a
fter
5 min
utes. To lock or unlo
ck pla
ce fi
nge
r o
ve
r
fu
nc
tio
n f
or
3
s
ec
on
ds
.
Test
Test
Pump Test
INSTALLATION INSTRUCTIONS
2. Outdoor Installation:
• During filling, draining or when in use, water may spill out of the
spa. Therefore the Lay-Z-Spa should be installed near a floor
drain.
• Do not leave the spa's surface exposed to direct sunlight for
long periods of time.
WARNING:
TO AVOID ELECTRIC SHOCK, DO NOT USE THE
SPA WHEN IT IS RAINING.
1. Indoor Installation:
Be aware of special requirements if you install the spa
indoors.
• Humidity is a natural side effect with Lay-Z-Spa
installation. Determine the effects of airborne moisture on
exposed wood, paper, etc. in the proposed location. To
minimize these effects it is best to provide plenty of
ventilation to the selected area. An architect can help
determine if more ventilation is needed.
WARNING:
The appliance must be located in Zone 1, 2 or outside of all zones.
4
S-S-001409
Selected Location
WARNING:
The selected location has to be capable of supporting the expected load.
WARNING:
An adequate drainage system has to be provided to deal with overflow water for both indoor and outdoor installations.
IMPORTANT:
Because of the combined weight of the Lay-Z-Spa, water, and users, it is extremely important that the base where the
Lay-Z-Spa is installed is smooth, flat, level and capable of uniformly supporting the weight for the entire time the Lay-Z-Spa is
installed (not on the carpet or other similar material). If the Lay-Z-Spa is placed on a surface, which does not meet these
requirements, any damage caused by improper support is not covered under the manufacturer’s warranty. It is the responsibility of
the Lay-Z-Spa owner to assure the integrity of the site at all times.