2 enter/exit programming mode (☆represents the default value).
3 contents contents .......................................................... 3 introduction .................................................... 4 setup steps ...................................................... 4 system setting ................................................ 5 sleep time selec...
4 introduction this is an advanced programming guide for omnidirectional laser barcode scanner. If you want to read the detailed user’s manual, please visit the official website to download or contact your dealer for detail. Setup steps in order to change the scanner setting, please follow the steps...
5 system setting ☆reset (return to factory default) reading of the “reset” barcode label turns all parameters back to default values, and the scanner remains in the last interface set when it is reset. Abort (exit programming mode).
6 after the replacement of different types of data lines, please do the following interface settings according to your optional data line. ☆return to pc/at default return to rs-232 default.
7 return to usb default return as customer default.
8 save as customer default sleep time selection in this section, user can set both laser and motor to either into sleep mode. The timeout programming labels will allow users to set the different time frame before entering into laser or motor sleep mode. The feature reduces power consumption and prol...
9 mode as motor enters sleep mode. Motor sleep mode off motor sleep time 10 minutes.
10 ☆motor sleep time 30 minutes laser sleep mode off.
11 ☆laser sleep time 10 minutes laser sleep time 30 minutes.
12 same code delay time in order to avoid an unwanted reading the same barcode, the time interval of the same barcode should not set too short. 50ms 200ms.
13 ☆300ms 500ms.
14 infinite beeper sound selection ☆power up tone enable.
15 power up tone disable tone low.
16 ☆medium high.
17 silent duration 50ms.
18 ☆100ms 200ms.
19 volume low medium.
20 ☆high barcode identifier code setting code 39.
21 itf 2 of 5 chinese postal code.
22 upc-e upc-a.
23 ean-13 ean-8.
24 codabar code 128.
25 code 93 msi.
26 rss-14 rss-14 limited.
27 rss expanded save setting to confirm.
28 message terminator rs-232 none ☆cr/lf.
29 cr tab.
30 stx/etx eot.
31 usb hid & keyboard wedge none ☆enter.
32 tab rs-232c interface configuration baud rate 1200
33 2400 4800
34 ☆9600 19200
35 38400 57600
36 115200 capital lock s hift.
37 ☆reset function key emulation enable.
38 ☆disable data edit prefix and suffix the prefix and suffix section allows you to append a prefix or suffix to every message. There is no restriction in selecting prefix or suffix characters as far as the sum of the lengths of prefix and suffix is not greater than 10 digits. 1. Scan the “enter/exi...
39 2. Select either prefix or suffix that you are going to program by scanning the corresponding label. If you want to add both prefix and suffix, you should operate separately; 3. Scan the characters you want to set as header or trailer from the full ascii. 4. Scan “saving setting to confirm” label...
40 suffix save setting to confirm.
41 truncate header/trailer character this setting allows you to truncate a number of header or trailer for symbology. As a result, the specific character you select is deleted from the symbology you want. 1. Scan the “enter/exit programming mode” label; 2. Select the “truncate header/ truncate trail...
42 truncate trailer save setting to confirm.
43 add code length this setting is used to set whether the barcode length character can be used as header. Enable disable.
44 reading code selection ☆code 39 enable code 39 disable.
45 codabar enable ☆codabar disable.
46 ☆upc/ean/jan enable upc/ean/jan disable (only can’t transmitted but can decode).
47 itf 2 of 5 enable ☆itf 2 of 5 disable.
48 chinese postal code enable ☆chinese postal code disable.
49 ☆code 128 enable code 128 disable.
50 code 93 enable ☆code 93 disable.
51 ean-128 enable ☆ean-128 disable.
52 ean convert to issn/isbn enable ean convert to issn/isbn disable.
53 code 32 enable ☆code 32 disable.
54 msi enable ☆msi disable.