LCD Concepts MES-6P-F User Manual - Precautions
3 |
P a g e
Connecting the Switch
PC to MES-6P-F
Connect the switch to a computer using a cable supplied by or purchased from Furuno with a
Furuno connector on one end and a RJ-45 connector on the opposite end.
Suggested Furuno cables: 000-159-689, 0.5 Meters
MES-6P-F to NavNet 2 or Other Ethernet Devices
The MES-6P-F can be connected to the NavNet 2 using the cables provided or purchased.
Suggested Furuno cables: 000-154-027, 1 Meter
000-154-049, 5 Meters
000-154-050, 10 Meters
The MES-6P-F can also be connected to other Ethernet devices using Furuno
cable/connectors and the appropriate RJ-45 adapter. The connection can be from any port on
the MES-6P-F to any of the MDI-X, 10Mbps or 100Mbps ports on another switch or other
device.
Port Speed and Duplex Mode
After plugging in the selected cable to a specific port, the MES-6P-F uses auto-negotiation to
determine the transmission mode, auto-detecting the network speed, 10Mbps or 100Mbps.
If the attached device does not support auto-negotiation or has auto-negotiation disabled, an auto-
sensing process is initiated to select the speed and half-duplex is selected.
Precautions
Switch to be installed 6’ from sources of electromagnetic noise (generators, etc.)
Not intended for prolonged submersion