LCN 4600CS Installation Instructions Manual - page 16
Page 16
CONTROLLER PROGRAMMING MODES
UP
DOWN
MODE
HOLD OPEN TIME
POWER
1
MODE
OPERATING
INDICATORS
2
3
4
5
6
7
8
9
90° SLOW DOWN TIME
ONE SHOT INPUT
EXTERIOR MODE
E.S. DELAY
E.S. 3 SEC. POWER
SEQUENTIAL DELAY
ALTERNATE ACTION TIME
LOCKOUT TIME
FIRE ALARM
NORMAL / SEQ
H.O. / ALT. ACTION
LOCKOUT TIMER
SAFETY CLEAR
SAFETY ACTIVE
1.
HOLD OPEN TIME:
Adjusts the amount of time door stays open after reaching the 90° position.
2.
90° SLOW DOWN TIME:
The time from start of door movement to a transition at approximately 70°, when door opening speed is
reduced.
3.
ONE SHOT INPUT (OFF/ON):
If off, hold open delay starts upon last activation input signal. If on, hold open delay starts upon first
activation input signal and ignores all others.
4.
EXTERIOR MODE (OFF/ON):
If off, door stops and hold open timer starts after door encounters first restriction. If on, door will pause
for 1 second upon first restriction(wind), then try to open again. Hold open timer starts after door encounters second restriction.
5.
E.S. DELAY:
Controls the time between activation signal and actual door movement. Allows time for electric latching hardware to
release before door starts to open. Default time should only be adjusted when using electric latching hardware.
6.
E.S. 3 SECOND POWER (OFF/ON):
If off, E.S. Relay is powered entire time door is open. Releases when door starts to close. If on,
E.S Relay is powered for only 3 seconds after door is activated, then releases.
7.
SEQUENTIAL DELAY:
Controls the time from first door activation to second door activation during sequential door application.
Should only be adjusted for sequential door application.
8.
ALTERNATE ACTION TIME:
Controls the time the door will remain open after an alternate action input is received. Provides an
automatic second input to close the door if a second alternate action input is not received within the preset time. Should only be set if
using alternate action door application.
9.
LOCKOUT TIME:
Controls the time that a safety scanner input is ignored during door closing. Should only be set if safety scanners
are used.