NOTICE:
The following procedures involve electrical connections and
running conduit for both high & low voltage wiring.
Electrical
power must be disconnected
during the installation of the
4600CS series door operator. It is also important to examine the
proper template for your installation to determine the mounting
channel position and correct conduit location.
SECTION 1
SECURING MOUNTING PLATE
ASSEMBLY TO FRAME
NOTE:
Before beginning installation, determine which conduit
connection option is to be used.
CONCEALED WIRING:
Both high & low voltage conduit lines should be run to door
frame and made accessible through two holes to be drilled in
frame per proper template on page 4 or 5.
SURFACE WIRING:
Mounting channel must be mounted to frame
BEFORE
running
high & low voltage conduit lines to the operator.
1. Prepare door and frame per template on page 4 for 4630CS/
page 5 for 4640CS. Be sure all holes are located correctly
before drilling and/or tapping. Mounting surface of frame
must be vertically level. Conduit access holes in frame are
for
CONCEALED WIRING ONLY!
If using concealed wiring
option, see step 2 below.
FOR SURFACE WIRING
, proceed to
step 3.
2. Refer to correct template to determine proper location for
conduit. Remove appropriate conduit plugs, exposing conduit
holes in back of mounting channel, as shown in
Fig 1
. Attach
1/2” conduit to mounting channel, as shown in
Fig 2
. Place
mounting channel into position on frame. Once mounting
channel is in position and flush on frame, insert fasteners and
tighten securely.
NOTE:
The conduit set-up shown is for a 4630CS mounting.
Conduit location will vary with other mountings.
CONNECTIONS
HIGH VOLTAGE
LOW VOLTAGE
CONNECTIONS
END CAP
REMOVED
FROM
THIS END
Fig. 1
HIGH
VOLTAGE
LOW
VOLTAGE
HIGH VOLTAGE
CONNECTIONS
LOW VOLTAGE
CONNECTIONS
END CAP
REMOVED
FROM
THIS END
Fig. 2
3. Position mounting channel on frame, connect conduit and
tighten securely.
CONDUIT THROUGH TOP OF MOUNTING CHANNEL:
After mounting plate is attached to frame, run 1/2” conduit to
access holes in top of mounting channel. Conduit should be
connected to channel as shown here in
Fig. 3
.
LOW VOLTAGE
CONNECTION
HIGH VOLTAGE
CONNECTION
Fig. 3