LDA NEO 8060 User Manual

Other manuals for NEO 8060: User Manual

Summary of NEO 8060

  • Page 1

    User's manual en 54-16 certified pa/va system lda neo.

  • Page 2

    Safety instructions please read carefully these safety instructions. 1. Keep this user manual for future reference. 2. Power connectors must stay accessible for disconnection and power cord must be placed where people will not step or stumble. Unplug the equipment from the ac/dc before cleaning. 3. ...

  • Page 3: Index

    Index 1 introduction............................................................................................................................ 1 2 description............................................................................................................................... 2 2.1 indica...

  • Page 4

    5.3 protection devices ............................................................................................................ 40 5.4 power supply ........................................................................................................................40 5.5 link....................

  • Page 5

    1 introduction the pa/va system lda neo is certified according to en 54-16, ensuring a safe and controlled emergency evacuation. Its high performance, versatility and audio quality make it also a powerful and cost-effective background music and paging system for all types of facilities. This documen...

  • Page 6

    2 description the main controller of the pa/va system manages all the audio inputs of the system, either conventional or emergency inputs, and routes them to the existing zones. The controller neo, follows all the requirements in accordance with en 54-16 and en 60849 normatives. In order to scale th...

  • Page 7

    (f) emg: “emergency” . Red active (on) when the equipment is in a state of emergency operation (voice alarm) or by manual or automatic activation from the cie, of any of the voice alarm zones. When the system is in a state of emergency and it is broadcasting a spoken voice, either through the emerge...

  • Page 8

    (p) emic: “emergency microphone” active (on) when the microphone is available to perform an emergency evacuation in the selected zones. If the indicator is off, wait for it to be turned on, a warning sound signal might be played. Amber colour. 2.2 controls 2.2.1 direct access controls these controls...

  • Page 9

    2.2.5 ack the button " ack " is situated under the button "reset " on the right side of the screen. I allows the con firmation that the emergency mode or fault status indication has been acknowledged. By pressing it, the emergency or fault audible beep will be muted. 2.2.6 control window the followi...

  • Page 10

    Once the selection has been made, press the "ok" control to con firm navigation, pressing the "back" button, the selection will be cleared. If you did not select any zone, and press "ok", and the equipment / system will perform an automatic selection of all zones. In each zone depicted on screen, it...

  • Page 11

    2.3 user profiles - access level. Passcode the access levels de fine the different user pro files that can operate the equipment / system. Each of the access levels, provides permissions to different menu items, level 1 having the lowest, and level 3 the highest number of options available. To acces...

  • Page 12

    2.4 inputs y outputs in this chapter are described the rear connectors of the neo series equipment. Depending on the model, the equipment will or will not include some of the types described in this section and quantity may vary. The monitoring interfaces for emergency power supply and general input...

  • Page 13

    2.4.2 emergency activation interface the emergency activation interface is indicated to perform an interconnection with a fire control and indication equipment (cie). All input connections are supervised in order to detect fault in the transmission line. This interface has three sections: (a) genera...

  • Page 14

    (b) supervised status outputs the equipment has two output signals, which indicate the operating state of the system. The emg signal indicates that the system is operating in emergency mode. Flt signal indicates that the system is in failure mode. They consist of two voltage-free contact closure out...

  • Page 15

    Marking description type signals activation ov-x attenuation of attenuators output output + - 24v dc 40ma table 5: attenuators override outputs note: the average consumption of the attenuator override signal is 10ma per unit. (*): the output voltage could vary between 20 and 27v depending on the sta...

  • Page 16

    The connection is made using standard cat 5 ethernet network cable rj-45 t568b (the connection cable is supplied with the equipment). Marki ng description type signals activation x/a/b ports for system connection port ethernet cat5 flexnet (propriety protocol) udp cobranet table 7: system connection...

  • Page 17

    Marking description type signals activation cfg port a : control data exclusively puert b : audio data exclusively puert x : flexnet** config. Na posición 00 cfg puert a : flexnet** puert b : flexnet** puert x : control data exclusively config. Na posición 01 cfg puert a : flexnet** puert b : flexne...

  • Page 18

    2.4.5 power supply every equipment in the neo series has double redundant power supply. (a) ac line voltage selector the equipment has an ac line voltage selector 230v / 115v, by default in the 230v position. Check the local line voltage to con figure the selector. Marking description type signals a...

  • Page 19

    2.4.6 speakers lines (a) spare channels input the equipment has 8 inputs back-up ampli fier channels per each internal ampli fier. Each connection has two terminals + and – where the redundant ampli fier output will be connected. The redundant ampli fier must be a 100v line public address ampli fier...

  • Page 20

    2.4.7 inputs and outputs of audio sources a ) record ouput the equipment has a line level balanced audio output, which includes a switching signal active at low level (ttl). It allows monitoring and recording the messages sent from the emergency microphone. When at one or more voice evacuation zones...

  • Page 21

    Marking description types signals activation audio outputs x balanced audio line level output replicant of the signal of the integrated amplifiers output ┴ + - na table 16: pre-amp/line-level outputs (e) audio source inputs the neo 8060 has 5 line-level balanced audio inputs. Input no.5 is shared wi...

  • Page 22

    The connection is made using 7 female connectors euroblock type with 3 contacts and pitch 3.81 mm (supplied with the unit). The wire size range for each pole of this connector is: 0.14 1.5 mm2 (30 14 awg). Marking description type signal s activation gpio x port general purpose i / o configurable in...

  • Page 23

    3 functioning 3.1 system booting before connecting the equipment to the electricity network, check that the equipment's rated voltage selector, located at the rear, is in the position corresponding to the power supply voltage available in the region, see chapter 2.4.5 for more information. Connect t...

  • Page 24

    Led indicators of evac or alert will turn on when a message is being played in any zone. B ) “select emic zones” for activation of emic in the selected zones. Select the zones and press the ptt button in the emg microphone to broadcast the announcement. The emic led will turn on indicating it is pos...

  • Page 25

    3.3 failure 3.3.1 failure state log the system has a log of detected failures. This log will be automatically displayed on the screen when the equipment / system is in this state for five minutes since the last entry occurred in the log. A whole year's log will be accessible through the con figurati...

  • Page 26

    Press the shortcut button "pa", the access control for users with level 2 will appear (see 2.3). To return, press the "back" button. Once passed the access control, the level of access authorization, will change to "level 2" and access the menu, which contains the options: zone volume setting, routi...

  • Page 27

    (d) volume indicator the volume indicator goes from -100db to 0db, minimum and maximum respectively zone volume. If a zone is selected , the current volume level will be displayed, and will be updated while you make the settings. If you have made a multiple selection, any value will be shown, until ...

  • Page 28

    (c) selection indicator when the audio source has been selected, a blue band selection within the source button will appear. (d) deroute audio source to clear the current assignment of an audio source to a zone / zones, select the source marked as an "x". A new routing is done automatically if you a...

  • Page 29

    3.5.4 avanced options. Audio input. (a) audio input selection buttons the audio inputs are in the left half of the screen. Click on the desired entry and if the progress indicator appears (see 2.2.6 ), use the scroll control to display the rest of available audio inputs. (b) “lda sound enhancement” ...

  • Page 30

    3.5.5 avanced options. Audio output. (a) audio output selection buttons in the left half of the screen, there are the audio outputs (output channel for ampli fier). Click on the desired output. If the progress indicator appears (see 2.2.6), use the scroll control to display the rest of outputs avail...

  • Page 31

    3.5.6 avanced options. Monitor (a) selection buttons on the left side of the screen there are buttons for selecting the element to be monitored. Click on the desired item. If the progress indicator is shown (see 2.2.6) use the scroll control to display the rest of elements available. (b) type of mon...

  • Page 32

    3.5.1 avanced options. Messages. (a) message list in the left column of the screen, you can find the list of pre-recorded messages. If the progress indicator is present (see 2.2.6), use the scroll control to display the remaining messages available. To select one, press its corresponding button in t...

  • Page 33

    To play a message, first select it in the left side column list and then press the play button. To pause or stop the playback, press the pause or stop buttons. If you would like to hear from the speaker monitor the selected message being played, use the monitor controls placed in the right side of t...

  • Page 34

    (b) system identifier in this section, you will find information of the equipment related to the system. First, there is the name or identi fier of the equipment, followed by the serial number associated with it. Below, you will see the version of the equipment's operating system, followed by the ve...

  • Page 35

    F ) network configuration button the network con figuration button, enters into the equipment's network con figuration menu. Note: you must press the ok button present in the numbers keyboard, as shown in the following picture, to save changes in the con figuration. (g) date and time settings/ ident...

  • Page 36

    4 connnection and setup 4.1 emergency supply system the equipment requires an external emergency power supply to work as an en 54 voice evacuation system. This power supply system must manage the battery charge and monitor the status of the external batteries that will provide the required power in ...

  • Page 37

    4.2 paging microphones and pa elements (acsi bus) the equipment has a connection for public address elements, such as microphones, remote panels, etc. The type of connection for all these elements is in bus mode. Each device is connected one after another, until a maximum of 8 devices, and a maximum...

  • Page 38

    The bandwidth that flexnet occupies in the standard ethernet network is of 25mb/s. On ethernet networks of 100mb/s, it works at network layer 2 for audio and layer 3 for communications. Operation of the connection between neo devices: the return connection to the port b will be generally on standby....

  • Page 39

    To make a connection, you must use the same cabling system that was used in the line of speakers for voice evacuation zones. 4.6 speaker lines the equipment has 8 independent ampli fication channels, each of them with two speakers line outputs. The power ampli fication of each channel is distributed...

  • Page 40

    4.6.3 supervision of speaker connections every speaker connection is supervised independently. There are two complementary ways to do it: measuring line impedance and end of line devices. Using the impedance of the line, the devices emits a signal periodically every 30 seconds, in a non audible freq...

  • Page 41

    Indicator description type signals activation orange speaker lines connection input ab 19khz pilot tone green connection to eol inputs output cd voltage-free contact closure between c and d (nc) table 20: connector of the eol note: do not connect the eol device to the secondary side of a volume cont...

  • Page 42

    Eol installation 1. Connect the two wires from the end of the speaker lines to the line terminator input. 2. Connect the two output cables of the end of line device to the line of input correspondent to the “end of line inputs” installation of the end of line device in a sequence with a con figurati...

  • Page 43

    4.7 volume controllers the device has 8 outputs for volume controls 24v (4-wires). The maximum number of attenuators that can handle each output must be calculated from the technical characteristics (see chapter 7). The connection of the end of line devices must be done in parallel, respecting the i...

  • Page 44

    5 failure detection 5.1 speakers line the system will indicate a failure in the speaker's line in case a short circuit or an open circuit has been detected or the impedance of the line has varied by at least 14%. If this error occurs, check the speci fied line in the system error log. To do this, di...

  • Page 45

    The system will indicate a link failure when there is a problem in the way of communication between distributed devices. If this failure occurs, you can see which are the equipment connected to the controller, in the window system, of the advanced options menu (3.5.2). Restart the equipment that is ...

  • Page 46

    6 maintenance instructions the equipment/system requires a reduced periodical maintenance. The periodicity of the maintenance must be adjusted in function of the condition of installation of the equipment/device. It is advisable that the maximum period for maintenance of the equipment should be of o...

  • Page 47

    7 technical features data (model) ac power 110-120v / 220-240v~ 50/60hz. Consumption - (neo8060) - (neo8250e) - (neo4250e) - (neo4500e) - (neo4500le) 550w max / 120w a 1/8 output power / 40w standby 900w max / 300w a 1/8 output power / 50w standby 900w max / 260w a 1/8 output power / 58w standby 900...

  • Page 48

    Emergency power status input euroblock type display screen tft 480 x 272, 4,3'' with resistive touch panel operating conditions -5 ºc to +45 ºc / 23 ºf to 113 ºf 5% to 95% relative humidity (no condensation) finish front: fe, grey ral 7016 rear: fe, black ral 9005 case: al, black ral 9005 weight - (...

  • Page 49

    Lda audio tech - severo ochoa nº 31- 29590 mÁlaga, espaÑa. Tlf: +34 952028805 45 user's manual: en 54-16 pa/va system lda neo.

  • Page 50

    8 appendix a: en 54-16 features neo implements all mandatory functions for compliance with the en54- 16: 2008. It includes the following optional features certi fied: 1. Audible warning 2. Phased evacuation 3. Manual mute of the voice alarm state 4. Manual reset of the voice alarm state 5. Exit voic...

  • Page 51

    Lda audio tech - severo ochoa nº 31- 29590 mÁlaga, espaÑa. Tlf: +34 952028805 47 user's manual: en 54-16 pa/va system lda neo.

  • Page 52

    9 appendix b: log content 9.1 state of emergency log • emg state active(local) • emg state active(remote) • emg state reset • emg state ack • evac msg on (zone x) • evac msg off (zone x) • alert msg on (zone x) • alert msg off (zone x) • emic on (zone x) • emic off (zone x) 9.2 state of failure log ...

  • Page 53

    10 appendix c: cabling section for speaker lines. The table below re flects the maximum desirable distance for 100v speaker lines. The type of cable that is used for the calculations is a two-wire type with copper conductor. The values shown may be used as a guide for planning, being the responsibil...

  • Page 54: Index Of Pictures

    Index of pictures picture 1: indicators............................................................................................................... 2 picture 2: controls..................................................................................................................4 picture 3: c...

  • Page 55: Index Of Tables

    Index of tables table 1: emergency source monitor inputs.......................................................................... 8 table 2: general emergency inputs.................................................................................... 10 table 3: system status outputs...................

  • Page 56

    Ver. 1.1 05- 2017.