Ledj spectra flood 18T3 User Manual - page 10
Spectra Flood 18T3
DMX Set up
9.
Notice:
• Be sure to follow figures 2 & 3 when making your own cables. Do not connect the cable’s shield
conductor to the ground lug or allow the shield conductor to come in contact with the XLR’s outer
casing. Grounding the shield could cause a short circuit and erratic behaviour.
Special Note: Line termination:
• When longer runs of cable are used, you may need to use a DMX terminator on the last unit to
avoid erratic behaviour (LEDJ260).
AC Plug:
• The Spectra Flood 18T3 features captive power cords terminated with IP66 connectors for power
input and power linking. The fixture is then supplied with a short 13A to IP66 connector power
cord. If at any stage the 13A plug is removed please follow the chart below. Any changes to the
connector types must be verified by a PAT test or equivalent electrical safety test.
Power linking:
• The Spectra Flood 18T3 supports power linking. You can link up to 8 products at 120 VAC or 16
at 240 VAC.
•This product supplied with a fixed power input cord. This product is not suppled with a power link
cable; however, power cables are available as an option (see page 8).
Termination reduces signal transmission problems
and interferance. it is always advisable to connect a
DMX terminal, (resistance 120 Ohm 1/4 W) between
pin 2 (DMX-) and pin 3 (DMX+) of the last fixture.