WIRE CONNECTIONS AND EQUIPMENT INSTALLATION
Check all wires for shorts to each other and for grounds. Connect all wires (EXCEPT 117 VAC CONNECTIONS TO TRANSFORMERS) as shown in the
connecting diagram FIG. 5 and in accordance with the wiring instructions. Refer to FIG. 6 for dual entrance wiring.
ENTRANCE PANEL (VM-300/4T):
A. Install frame (OF-200 series) into housing (BB-200 series).
B. Connect all wires necessary as shown in connecting diagram FIGURE. 5. Refer to FIGURE. 6 for dual entrance wiring.
C. Connect coaxial video cable (RG-59U) to the camera cable connector on the back of the camera. Connect the remaining wires from the cable connector
to CN and CP to supply power.
D. Install the front panels into frame following the directions included with the directory panel.
VIDEO MONITOR (VM-104):
A. Connect all necessary wires as shown in the connecting diagram FIG. 5. Refer to FIG. 6 for dual entrance wiring. IH-357 and IH-358 housing includes
four knock-out holes for cable inlet.
B. Mount the VM-104 to the IH-357 and IH-358 ring housing using the adapter plate.
TRANSFORMER (PS-250):
A. Connect transformer 16 volt terminals to PK-314A, terminals T1 and T2. Connect transformer primary to 117 VAC observing all applicable electrical codes.
SYSTEM CHECK-OUT
Check entire system according to the operating instructions, turning each monitor on individually so that if a problem exists it may be easily identified. If the
system does not operate as indicated, refer to Trouble Shooting section.
OPERATING INSTRUCTIONS
A.
AT ENTRANCE PANEL (VM-300/4T Van-Guard
®
, or QM-300/2 Quantum
TM
):
1. Momentarily press button corresponding to desired suite.
2. Reply in a normal voice when spoken to. Reply is hands-free.
3. When door release buzzes, enter through door.
B.
AT SUITE STATION (VM-104):
1. When call tone is heard, pick up intercom handset.
2. Adjust picture brightness and contrast as necessary using the slide control switches located just below lower right corner of video screen.
3. Identify caller on the video screen and converse with them.
4. The door may be opened by pressing the door release button marked "Door".
Each monitor stays on for approximately 1 minute when called. Picture is delayed approximately 3 to 5 seconds. When the door release is activated or when
a second caller rings another suite, the monitor will shut off.
Calls may also be initiated from the VM-104 by pressing the video monitor button marked "Monitor". This activates the camera and may be used to re- initiate
a call that has been canceled, or to monitor the entrance panel. The monitor will stay on for approximately 1 minute. Only 1 monitor at a time should be on
using video monitor button.
If standby control is switched ON, red LED will light and monitor will remain on standby, ready to operate when another call is placed from the entrance panel.
NOTE: Performance may vary with large or small installations. If no video contact with the entrance is desired or if a tenant is leaving the suite, the standby
switch may be turned OFF. Audio communication will still operate in the normal manner.
SYSTEM MAINTENANCE
ENTRANCE PANEL (VM-300/4T):
Directory panels are accessible by removing the self-tapping metal screw(s) located in the top L-channel just above each module. After removing screws,
lift L-channel away from frame. Panel can now be removed. Apply directory listings as desired and replace panels be reversing the above procedure.
CONTROL UNIT (PK-314A):
Each PK-314A has a 5 amp, 3AG fuse as an overload protection. Replace this fuse with same type and rating only. If this fuse continually opens, check
for wrong wiring or equipment failure.