Additional Warnings and Notices
Carbon Monoxide (CO) Awareness
Carbon monoxide, referred to as CO, is a colorless, odorless gas that is produced during combustion of coal and other fuels. CO fumes
are toxic and can be fatal.
e TLC 2000 is a natural draft system which relies on a properly designed chimney to remove CO
and other combustion by-products from the stove. Even though this stove is designed to be as safe as possible, it is important that you
install a CO detector.
is is true for oil, gas, or wood as well. CO is not specifcally heavier or lighter than air.
erefore, it is best to
install the detector at table top level rather than on the ceiling like a smoke detector.
CO detectors are very sensitive and may sound an alarm for fumes other than CO or CO from sources other than the stove such as car
or lawn mower exhaust. If the alarm sounds
1. Increase ventilation by opening windows or doors.
2. Make sure the stove doors are closed and latched.
3. Check stove for normal operation.
4. Check for false alarm.
5. Have all occupants exit the building until the cause for the alarm is discovered and/or remedied.
THIS APPLIANCE IS ALSO APPROVED FOR INSTALLATION INTO A SHOP.
NEVER SLEEP IN THE SAME ROOM WITH ANY COAL BURNING STOVE!
CAUTION! NEVER USE GASOLINE,
GASOLINE-TYPE LANTERN FUEL,
KEROSENE, CHARCOAL LIGHTER FLUID,
OR SIMILAR LIQUIDS TO START OR
FRESHEN UP A FIRE IN THIS HEATER. KEEP
ALL SUCH LIQUIDS WELL AWAY FROM THE
HEATER WHILE IT IS IN USE
WARNING: DO NOT INSTALL A FLUE
DAMPER IN THE EXHAUST VENTING
SYSTEM OF THIS APPLIANCE. DO NOT
CONNECT THIS UNIT TO A CHIMNEY FLUE
SERVING ANOTHER APPLIANCE.
CAUTION! FAILURE TO FOLLOW THE
INSTALLATION INSTRUCTIONS IN THIS
MANUAL, OR USING MAKESHIFT
COMPROMISES DURING INSTALLATON MAY
RESULT IN PROPERTY DAMAGE,
PERSONAL INJURY OR DEATH!
DO NOT CONNECT TO ANY AIR
DISTRIBUTION DUCT OR SYSTEM
DO NOT USE CHEMICALS OR FLUIDS TO
START A FIRE.
DO NOT BURN GARBAGE OR FLAMMABLE
LIQUIDS SUCH AS GASOLINE, NAPTHA, OR
ENGINE OIL.
HOT WHILE IN OPERATION. KEEP
CHILDREN, CLOTHING AND FURNITURE
AWAY. CONTACT MAY CAUSE SKIN BURNS.
WHEN INSTALLING IN A TIGHTLY
CONSTRUCTED HOME, A SOURCE OF
FRESH AIR TO THE ROOM MAY BE
NECESSARY FOR PROPER OPERATION OF
THE APPLIANCE.
DO NOT INSTALL IN A MOBILE HOME
-8-