Legend 739ILN Owner's Manual

Manual is about: dv gas insert

Summary of 739ILN

  • Page 1

    L egend 4001839-12 ©2011, miles industries ltd. Manufactured by miles industries ltd., british columbia, canada www.Valorfi replaces.Com dv gas insert (logs) 739iln (ng) & 739ilp (lpg) installation and owner’s manual warning: if the information in these instructions is not followed exactly, a fi re ...

  • Page 2: Do Not Put

    We recommend that our gas hearth products be installed and serviced by professionals who are certifi ed in the united states by nfi (national fireplace institute ® ). Thank you ... For purchasing a valor by miles industries. Your new radiant gas heater is a technical appliance that must be installed...

  • Page 3: Safety And Your Fireplace

    Safety and your fireplace safety and your fireplace please follow these important child safety precautions and recommendations, • parts of your valor fireplace become extremely hot while in operation. • the glass viewing window temperature can exceed 500 f at full capacity. Momentary contact with a ...

  • Page 4

    Safety and your fireplace .............................................................................3 safety and warning information...................................................................5 specifi cations ...................................................................................

  • Page 5

    Owner’s info safety and warning information children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid burns or clothing ignition. Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young childr...

  • Page 6

    Owner’s info x x safety and warning information ratings model ng lpg gas natural propane altitude (ft.)* 0-4,500 feet* input maximum (btu/h) 26,000 24,000 input minimum (btu/h) 6,500 13,000 manifold pressure (in w.C.) 3.6 10.0 minimum supply pressure (in w.C.) 5.0 11.0 maximum supply pressure (in w....

  • Page 7

    Installation overview this appliance may only be installed in an existing unaltered, functioning solid-fuel burning fi replace with a working fl ue and constructed of non-combustible material. Do not install into combustible construction. This appliance is not approved for installation with a zero c...

  • Page 8

    Installation 28-5/8” (727 mm) 19-1/2” (495 mm) 12” (305 mm) or 12-5/8” (321 mm) varies with outer trim options 9-3/8” (238 mm) or 10” (254 mm) varies with outer trim options 20” (508 mm) gas inlet gas connection electrical inlet optional outer trim or surround sold separately x y dimensions cavity c...

  • Page 9

    Installation 9” (229 mm) a b do not put furniture or objects within 36” (914 mm) of the front of appliance combustible mantel clearances *measure taken from the underside of the mantel to fi nished hearth or surface that the unit is sitting on. Finishing materials combustible materials: material suc...

  • Page 10

    Installation 3” liners 3” min. Bend radius terminal cap flashing 2 x 3” fl ex liners—see venting table for length allowed typical vent installation see list of approved venting accessories on page 29 of this manual. Vent location the vent terminal must be located through the roof. This direct vent a...

  • Page 11

    Installation installation planning installer—read this first 1. You need to know from the homeowner what accessories (surround, door, etc.) will be installed with this fi replace; 2. Unpack the appliance. 3. Check that you have everything. 4. Clean cavity, chimney, ash dump, and clean-out. 5. Instal...

  • Page 12

    Installation unpacking the appliance beware of sharp edges! Wear gloves! 1. Unpack the appliance. 2. Unpack any loose items from around the appliance and check against the pack content list provided in the documentation package. 3. Remove the window and set aside in a safe place to avoid damage—see ...

  • Page 13

    Installation appliance preparation window removal the window is held in place by four spring-loaded bolts, two at the top and two at the bottom. 1. To remove the window, turn each bolt a quarter turn to disengage the bolt pin. 2. Gently pull the bottom of the window outward and unhook it from the fi...

  • Page 14: Option 2B

    Installation venting installation important: this appliance’s venting system is room sealed and therefore, does not require room air to be used in the combustion process. 1. Rough-in two 3” diameter vent liners into the existing chimney system from the roof. Be careful not to tear or damage the line...

  • Page 15

    Installation supply pressure test tapping manifold pressure test tapping gas supply installation the gas supply inlet connection is a 3/8” npt female connector and is located on the left hand side of the control valve. Use only new black iron or steel pipes or copper tubing if acceptable—check local...

  • Page 16

    Installation ceramic bricks installation the following guidelines apply for all brick liners. 1. Inside the fi rebox, on the top of each side, release the screw of the side brick anchors (one per side) just enough to allow them to rotate. 2. Place the rear panel against the back of the fi rebox, on ...

  • Page 17

    Installation both front logs to rest slightly on the edge of the fi rebox window frame. 5. Identify the right cross log; it has a hole under on of its end and it is the shortest cross log. Place it on the right pin located on the rear log. Rest its other end in the crook of the front right log. 6. I...

  • Page 18

    Installation bottom of window (wider frame) window refi tting 1. To refi t the window, hook its top part to the fi rebox’s opening frame. Make sure that the wider part of the window frame is at the bottom. 2. While you hold it, push in and turn the two top spring-loaded bolts a quarter turn to engag...

  • Page 19

    Installation packing contents: 1 wall bracket a 2 screws b 1 screw c 2 wall anchor d 1 spacer e (detach before assembly) 1 wall bracket f switch plate alternative 1 alternative 2 alternative 3 remote control handset wall holder installation the remote control kit for this fi replace comes complete w...

  • Page 20

    Owner’s info read the safety information on pages 3 and 5 of this manual. Operating your fireplace for your safety, this appliance is fi tted with a fl ame supervision device which will shut-off the gas supply if, for any reason, the pilot fl ame goes out. This device incorporates a fi xed probe, wh...

  • Page 21

    Owner’s info bottom of window (wider frame) to refi t the window: 1. To refi t the window, hook its top part to the fi rebox’s opening frame. Make sure that the wider part of the window frame is at the bottom. 2. While you hold it, push in and turn the two top spring- loaded bolts a quarter turn to ...

  • Page 22

    Owner’s info on off manual on/off switch owner’s information lighting, operation and rating information the lighting, operation and rating information is located on a plate under the burner. To access the plate, remove the fret or access panel, grab the plate and take it out to read it. There is imp...

  • Page 23

    Owner’s info remote control operation your fi replace remote control helps you get the comfort, convenience and aesthetics you want from your gas fi replace. The remote controls your fi replace in different ways. Important: before you begin, please note that on this system, the settings of time, tem...

  • Page 24

    Owner’s info remote control operation operation modes man man mode —manual mode. You can use this mode to adjust the flame height up or down. ☼ temp temp mode —daytime temperature mode (appliance must have pilot ignited): the room temperature is measured and compared to the set temperature. The flam...

  • Page 25

    Owner’s info remote control operation temperature use this setting when you come in and want to enjoy a set temperature. 1. Select either the ☼ temp mode or the ☽ temp mode by briefly pressing the set button. 2. Hold the set button until the temp display flashes. 3. Set the desired temperature with ...

  • Page 26

    Owner’s info remote control operation options venting (required) see approved venting accessories listed below. Inner front (required) see your dealer for your choice of inner fronts. Outer surrounds, trims & frets (optional) see your dealer for your choice of outer surrounds and trims and frets. Op...

  • Page 27

    Owner’s info lighting instructions warning : if you do not follow these instructions exactly a ¿re or exslosion pay result causinj sroserty dapaje sersonal inmury or loss of life )ij )ij )ij a for your safety, read before lighting a. This appliance has a pilot which must be lighted by hand or by rem...

  • Page 28

    Installation optional wall switch kit 1265wsk connector red yellow gv60 wiring diagram wiring diagram 28.

  • Page 29

    Installation venting accessories approved direct vent suppliers for valor models 739 & rf24dv venting parts description venting parts code / availability by manufacturer simpson dura-vent selkirk icc excel direct secure vent rlh industries miles industries t ermination caps v ertical standard co-axi...

  • Page 30: Lor

    Owner’s info warranty 1. Extended warranty coverage for a period of up to ten (10) years, miles industries ltd., (the “company”) or its appointed distributor will at its option pay the initial purchaser for the repair of, or will exchange the following parts or components which are found to be defec...

  • Page 31

    Owner’s info code description part number 1 exhaust slide assembly 4001133 2 exhaust slide gasket 4000176 3 fan closure plate 4001136 4 port cover 4001820ah 5 log support 4001841 6 side bricks anchors (2) 4001283 7 top mounting bracket 4000136by 8 side mounting brackets (2) 4000135by 9 window assemb...

  • Page 32

    Owner’s info spare parts ng lpg 18 20 25 21 22 23 24 19 49a 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 44 43 45 62 63 64 65 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 14a ng lpg 13a 32.

  • Page 33

    Thank you ... For purchasing a valor by miles industries. Your new radiant gas heater is a technical appliance that must be installed by a qualifi ed dealer. Please circle where appropriate - ask your installer or your dealer if in doubt. The information provided will be used for customer records on...

  • Page 34

    Tape shut thank you for choosing a valor product postage needed miles industries ltd. 190 - 2255 dollarton highway north vancouver, bc v7h 3b1 canada fold here online warranty registration at www.Valorfi replaces.Com.