    1 operating manual bedienungsanleitung online preamplifier online-vorverstärker 97211.

  • Page 2

    2 r 97115 97118 97119 r r r 97110 change off on power refill empty 97106 97125 97108 97127 97110 97123 r 97123 esc 97103 97204 r 97103 esc a b a b b a 97115 97118 97119 97211 loctite deutschland gmbh made in germany cat. No. 97211 r 97211 output 1v 5v 10v 1x 2x 1x 2x 1x 2x 2x 1x 1x 2x z6113100 z6113...

  • Page 3: Contents

    3 contents english ...................................................................................................................... 4-32 deutsch................................................................................................................... 33-59.

  • Page 4: Contents

    4 contents 1 please observe the following ......................................................................................6 1.1 emphasized sections.....................................................................................................6 1.2 items supplied.............................

  • Page 5

    5 5 measuring ................................................................................................................... 18 5.1 adjusting of the dispense quantity.............................................................................. 18 5.2 adjusting the preamplifier 97211 .............

  • Page 6

    6 1 please observe the following for safe and successful operation of the unit, read these instructions completely. If the instructions are not observed, the manufacturer can assume no responsibility. Be sure to retain this manual for future reference. Refer to the technical data sheet for the locti...

  • Page 7

    7 1 please observe the following 1.2 items supplied 1 preamplifier 97211 1 connection cord preamplifier to controller 1 operating manual 97211 purchasing the preamplifier 97211 includes the permission to use the monitor software of the controller 97103 and 97123. As a result of technical development...

  • Page 8

    8 1 please observe the following 1.4 field of application (intended usage) the integrated flow monitor of a loctite controller in connection with the preamplifier online monitor 97211 is used for monitoring the quality and quantity of adhesive dispensed on parts, i.E. The flow monitor recognizes and...

  • Page 9: 2    Description

    9 2 description 2.1 theory of operation the integrated flow monitor of the loctite controller in connection with the preamplifier 97211 measures the dispense pressure characteristic by means of a pressure sensor and stores this parameter. The pressure sensor is integrated in the dispensing valve. Th...

  • Page 10: 2    Description

    10 2 description it measures the last preceding dispensing cycle relative to a reference measurement previously recorded and found to be o. K. All adjustments have to be done in the setup menu of the controller, to make sure that authorized personnel can store this reference value only. Tolerance ca...

  • Page 11: 2    Description

    11 2 description at the preamplifier online monitor 97211 the amplification factor has to be adjusted to get an optimum signal for correct interpretation at the loctite controller. Before each new start of a dispensing cycle, the controller generates a ready signal or fault signal. This happens at t...

  • Page 12: 2    Description

    12 2 description 2.2 displays, operating elements and connections 1 led row 1-10 v output displays the measured and amplified signal from the sensor during a measuring. The best adjustment of the amplification is during a measuring (dispensing) the signal will be not higher than 5 v. It has to be ad...

  • Page 13: 3    Technical Data

    13 3 technical data power input 24 vdc power output 1 – 10 vdc protection grade ip 65 dimensions w x h x d: 80 mm x 57 mm x 141 mm: operating temperature +10 °c to +40 °c (+50 °f to +104 °f) storage temperature -10 °c to +60 °c (+14 °f to +140 °f) weight 0,24 kg continuous noise level max length of ...

  • Page 14: 4    Installation

    14 4 installation 4.1 environmental and operating conditions - non-condensing humidity. - no splash water. - housing may not get in touch with solvent! 4.2 space requirements 1v output 97211 5v 10v henkel loctite deutschland gmbh arabellastr. 17 81925 m nchen made in germany cat. No. 97211.

  • Page 15: 4    Installation

    15 4 installation 4.3 connecting the unit • use only the cable supplied 4.3.1 automatic controller 97123 4.3.2 dual channel automatic controller 97103 90-260 vac 47-63 hz phase = 1 xs1 star t xs2 reser voir xs3 flo w monitor xs5 plc interf ace xs4 rs232 2 am cat. No. 97123 loctite (ireland) ltd. Tal...

  • Page 16: 4    Installation

    16 4 installation 4.3.3 pressure sensor handle sensor with absolute care! No scratching or touching of the membrane! Never exceed a pointed pressure load in the extremely thin and sensitive sensor diaphragm. Otherwise the sensor will be destroyed! Absolutely consider the tightening torque described ...

  • Page 17: 4    Installation

    17 4 installation 4.4 disconnect the pressure sensor.

  • Page 18: 5    Measuring

    18 5 measuring the operating manual of the used equipment is required. The adjustments of the preamplifier (section 5.1 - 5.6) in connection with the multichannel controller 97153 are described in the operating manual of the 97153. The sequence of the first installation of the complete system is des...

  • Page 19: 5    Measuring

    19 5 measuring 5.2 adjusting the preamplifier 97211 the amplification factor has to be adjusted in order to get an optimum signal to noise ratio for correct interpretation by the loctite controller. When you start dispensing a signal is available. The range of the amplified signal is 1-10v (1-10 led...

  • Page 20: 5    Measuring

    20 5 measuring 5.3 setup at the controller • open the main directory periphery setup, see operating manual of the used controller. • set the directory point flow.Monitor respectively disp.Control from [ o ] to [ i ]. The subdirectory is open. • choose the required tolerance and store it. Toler.: low...

  • Page 21: 5    Measuring

    21 5 measuring 5.4 storing a reference in order to monitor dispensed quantities, reference-dispensing cycles have to be made. Only for the automatic controller 97103: choose the dispensing channel in which the dispensing is required to be monitored. • to get the reference mode first press the button...

  • Page 22: 5    Measuring

    22 5 measuring 5.5 monitoring 5.5.1 normal monitoring mode the flow control system controls the following characteristic values: t measured time in 1/100 seconds i integral, represents dispensing pressure and quantity. This value should act linear to the dispensed quantity so the increase (decrease)...

  • Page 23: 5    Measuring

    23 5 measuring when very small quantities are required then use – dispensing valve 98013 with integrated pressure sensor, – a not too low viscose adhesive and – the conical dispensing needle with the smallest possible diameter. Check the measured values at a laptop or use an oscilloscope. In case of...

  • Page 24: 5    Measuring

    24 5 measuring 5.5.2 extended monitoring mode this option requires knowledge of serial data communication! In this mode you can select several dispensing cycles for monitoring at your own choice. Therefore you have to set up the serial interface at your pc or plc, connect this interface with the loc...

  • Page 25: 5    Measuring

    25 5 measuring 5.6 software interface for statistic process control (spc) the flow monitoring system offers you the possibility to get data for further process control. The system provides the measured data at the serial i/o port on the controller. The process data contains information about – numbe...

  • Page 26: 5    Measuring

    26 5 measuring example for a reference measurement. Ref: 0 t:00120 i:01443 h:00697 tol:015% ref: reference tol:015% adjusted tolerance 15 %. Example for a measurement with error. Meas: 0 t+00180 i:01443 h–00476 o:00354 the + means the value lies over the adjusted tolerance of the reference measureme...

  • Page 27: 7    Troubleshooting

    27 6 care, cleaning and maintenance the preamplifier needs no care and maintenance. Cleaning do not use solvent to clean the housing. 7 troubleshooting type of malfunction possible causes corrections no led lights. – no 24 v supply. – pressure sensor is defect. – sensor cord is defect. – led is defe...

  • Page 28: 8    Annex

    28 8 annex 8.1 spare parts pos. No. Description loctite order no. – pressure sensor 3.5 bar, m5, coated for anaerobic products 8952025 – pressure sensor 35 bar, m5, coated for anaerobic products 8952026 – pressure sensor 70 bar, m5, uncoated version for silicones 8952027 – protected pressure sensor ...

  • Page 29: 8    Annex

    29 8 annex 8.2 pin assignment 8.2.1 4 pin plug for connection to controller 8.2.2 4 pin socket for connection to the pressure sensor 1 2 3 1 2 3 4 4 5 6 7 8 9 analogue out 0-10vdc +0vdc +24vdc black blue white brown preamplifier 97211 controller 1 schwarz black 4 rot red 2 grün green 3 weiß white ge...

  • Page 30: 8    Annex

    30 8 annex 8.2.3 plc interfaces xs 5 controller 97123 and xs 9 controller 97103 (internal voltage) 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 10 11 12 13 14 15 1 2 3 4 2 3 1 4 1 1 1 1 1 2 2 2 2 2 1 2 gnd ready error start reset tank refill tank empty controller plc pot. 24 v pot. 0 v + 24...

  • Page 31: 8    Annex

    31 8 annex 8.2.4 plc interfaces xs 5 controller 97123 and xs 9 controller 97103 (external voltage) 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 + 24vdc 10 11 12 13 14 15 10 11 12 13 14 15 1 2 3 4 2 3 1 4 1 1 1 1 1 2 2 2 2 2 1 2 gnd 0 vdc/gnd ready error start reset tank refill tank empty controller plc pot. ...

  • Page 32: 8    Annex

    32 8 annex 8.3 declaration of conformity declaration of conformity in accordance with the ec regulations for electro-magnetic compatibility 89/336/eec, appendix i the manufacturer henkel loctite deutschland gmbh arabellastraße 17 d-81925 münchen declares that the unit designated in the following is,...

  • Page 33: Inhaltsverzeichnis

    33 inhaltsverzeichnis 1 bitte beachten sie...................................................................................................... 35 1.1 hervorhebungen .......................................................................................................... 35 1.2 lieferumfang .........

  • Page 34

    34 5 messen ........................................................................................................................47 5.1 einstellen der dosiermenge .........................................................................................47 5.2 einstellen des online vorverstärkers 9...

  • Page 35: 1    Bitte Beachten Sie

    35 1 bitte beachten sie für den gefahrlosen und erfolgreichen einsatz des gerätes diese anleitung vollständig lesen. Werden die anweisungen nicht befolgt, übernimmt der hersteller keine garantie. Bewahren sie diese anleitung nach durchsicht griffbereit auf. Beziehen sie sich auf das technische daten...

  • Page 36: 1    Bitte Beachten Sie

    36 1 bitte beachten sie 1.2 lieferumfang 1 online vorverstärker 97211 1 anschlusskabel vorverstärker - steuergerät 1 bedienungsanleitung 97211 der erwerb des online vorverstärkers 97211 schließt die lizenz zur benutzung der steuerungs-software für die steuergeräte 97103 und 97123 mit ein. ☞ bedingt ...

  • Page 37: 1    Bitte Beachten Sie

    37 1 bitte beachten sie 1.4 einsatzbereich (bestimmungsgemäße verwendung) die integrierte durchflussüberwachung eines loctite-steuergeräts wird in verbindung mit dem online vorverstärker 97211 zur Überwachung der qualität und der menge des klebstoffs eingesetzt, der auf teile aufgetragen wird. Das h...

  • Page 38: 2    Gerätebeschreibung

    38 2 gerätebeschreibung 2.1 funktionsbeschreibung die integrierte durchflussüberwachung eines loctite-steuergeräts misst in verbindung mit dem online vorverstärker 97211 über einen drucksensor den dosierdruckverlauf und speichert diesen. Der drucksensor ist in das dosierventil integriert. Die dauer ...

  • Page 39: 2    Gerätebeschreibung

    39 2 gerätebeschreibung das gerät misst den letzten dosierzyklus und vergleicht ihn mit einer vergleichsmessung, die zuvor gespeichert und für o.K. Befunden wurde. Alle einstellungen müssen am steuergerät im setup-menü vorgenommen werden, um sicherzustellen, dass dieser vergleichswert nur von autori...

  • Page 40: 2    Gerätebeschreibung

    40 2 gerätebeschreibung an dem online vorverstärker 97211 muss der verstärkungsfaktor so eingestellt sein, dass ein optimales signal das loctite-steuergerät erreicht und korrekt ausgewertet wird. Am ende eines dosierzyklus generiert jedes mal das steuergerät entweder die meldung “ready” oder “fault”...

  • Page 41: 2    Gerätebeschreibung

    41 2 gerätebeschreibung 2.2 anzeigen, bedienelemente und anschlüsse 1 led-block 1-10 v output zeigt das während einer messung gemessene und verstärkte signal vom sensor an. Am besten wird die verstärkung während einer messung (dosierung) eingestellt. Das signal muss am potentiometer 3 eingestellt we...

  • Page 42: 3    Technische Daten

    42 3 technische daten versorgungsspannung 24 vdc analog-ausgangsspannung 1 - 10 vdc schutzgrad ip 65 abmessungen b x h x t: 80 mm x 56 mm x 140 mm betriebstemperatur +10 °c bis +40 °c (+50 °f bis +104 °f) lagertemperatur -10 °c bis +60 °c (+14 °f bis +140 °f) gewicht 0,24 kg dauerschalldruckpegel ma...

  • Page 43: 4    Installieren

    43 4 installieren 4.1 umgebungs- und betriebsbedingungen - keine kondensierende luftfeuchtigkeit. - kein scharfer spritzwasserstrahl. - gehäuse nicht mit lösemittel in berührung bringen. 4.2 platzbedarf 1v output 97211 5v 10v henkel loctite deutschland gmbh arabellastr. 17 81925 m nchen made in germ...

  • Page 44: 4    Installieren

    44 4 installieren 4.3 anschließen des gerätes • das mitgelieferte kabel verwenden. 4.3.1 universalsteuergerät 97123 4.3.2 2-kanal-universalsteuergerät 97103 xs1: start xs2:reservoir xs3:turntable xs4: dc motor xs5: monitor a xs6: monitor b xs7: rs232 master xs8: rs232 slave xs9: plc interface xs10:i...

  • Page 45: 4    Installieren

    45 4 installieren 4.3.3 drucksensor sensor mit absoluter vorsicht behandeln! Niemals membrane zerkratzen oder berühren! Die maximale druckbelastung für die extrem dünne und empfindliche membran niemals überschreiten. Der sensor wird sonst zerstört! Unbedingt das unten angegebene anzugsmoment beachte...

  • Page 46: 4    Installieren

    46 4 installieren 4.4 entfernen des drucksensors.

  • Page 47: 5    Messen

    47 5 messen die bedienungsanleitung des verwendeten gerätes ist erforderlich. Die einstellung des vorverstärkers (kapitel 5.1 bis 5.6) in verbindung mit dem mehrkanal-steuergerät 97153 werden in der bedienungsanleitung des 97153 beschrieben. Der ablauf der ersten installation des kompletten systems ...

  • Page 48: 5    Messen

    48 5 messen 5.2 einstellen des online vorverstärkers 97211 der verstärkungsfaktor muss so eingestellt werden, dass ein optimales signal das loctite-steuergerät erreicht und korrekt ausgewertet werden kann. Beim start des dosiervorgangs ist ein signal verfügbar. Das verstärkte signal liegt im bereich...

  • Page 49: 5    Messen

    49 5 messen 5.3 einrichten des steuergerätes • Öffnen sie das hauptverzeichnis periphery setup (siehe bedienungsanleitung des verwendeten steuergerätes). • den verzeichnispunkt flow.Monitor bzw. Disp.Control von [ o ] auf [ i ] umschalten. Das unterverzeichnis ist offen. • erforderliche toleranz aus...

  • Page 50: 5    Messen

    50 5 messen 5.4 erstellen eines vergleichswertes zur Überwachung der dosiermengen müssen vergleichsdosierungen durchgeführt werden. Nur für universalsteuergerät 97103: dosierkanal für die Überwachung der dosierung auswählen. • zum aufrufen des vergleichsmodus zuerst die taste drücken, gedrückt halte...

  • Page 51: 5    Messen

    51 5 messen 5.5 Überwachen 5.5.1 normaler Überwachungsmodus die durchflussüberwachung überwacht die folgenden kennwerte: t gemessene zeit in 1/100 sekunden i integral, entspricht dosierdruck und menge. Dieser wert sollte sich linear zur dosiermenge verhalten, so dass erhöhung bzw. Abfall des drucks ...

  • Page 52: 5    Messen

    52 5 messen wenn sehr kleine dosiermengen benötigt werden, verwenden sie bitte – dosierventil 98013 mit integriertem drucksensor, – einen nicht zu niedrigviskosen klebstoff und – die konische dosiernadel mit dem kleinstmöglichen durchmesser. Messwerte an einem laptop überprüfen oder oszilloskop verw...

  • Page 53: 5    Messen

    53 5 messen einrichten der seriellen schnittstelle sämtliche zeichen müssen großgeschrieben und sollten im ascii-code gesendet und empfangen werden. Setup: baudrate 9600 parität keine datenbit 8 handshake xon/off stopbit 1 steckerbelegung der plc-schnittstelle xs 5 (97123) siehe abschnitt 8.2. Befeh...

  • Page 54: 5    Messen

    54 5 messen 5.6 software-schnittstelle für die statistische prozesskontrolle (spk) das durchflussüberwachungssystem bietet die möglichkeit, daten für weitere prozesskontrollvorgänge abzurufen. Voraussetzungen für das abrufen von prozessdaten sind die verbindung des durchflussüberwachungssystems zu e...

  • Page 55: 5    Messen

    55 5 messen beispiel einer referenzmessung ref: 0 t:00120 i:01443 h:00697 tol:015% ref: 0 referenz nummer 0 tol:015% eingestellter toleranzwert 15% beispiel einer messung mit fehler meas: 0 t+00120 i:01443 h–00697 o:00354 + heißt, der gemessene wert liegt über der eingestellten toleranz im vergleich...

  • Page 56

    56 6 pflege, reinigung und wartung der online vorverstärker bedarf keiner besonderen pflege, reinigung und wartung. Reinigen zum reinigen des gehäuses keine lösemittelhaltige reiniger verwenden. 7 beseitigen von störungen art der störung mögliche ursachen abhilfe keine led leuchtet. – keine 24-v-ver...

  • Page 57: 8    Anhang

    57 8 anhang 8.1 ersatzteile pos. Nr. Gerätebeschreibung loctite-bestellnummer – drucksensor 3.5 bar, m5, beschichtet für anaerobe produkte 8952025 – drucksensor 35 bar, m5, beschichtet für anaerobe produkte 8952026 – drucksensor 70 bar, m5, unbeschichtete version für silikone 8952027 – geschützter d...

  • Page 58: 8    Anhang

    58 8 anhang 8.2 steckerbelegung 8.2.1 4-pol. Stecker für anschluss an steuergerät 8.2.2 4-pol. Buchse für anschluss des drucksensors 1 schwarz black 4 rot red 2 grün green 3 weiß white gegen-uhrzeigersinn lötseitig gesehen counterclockwise viewed from solder side 1 2 3 4 1 2 3 4 0vdc 10vdc signal si...

  • Page 59: 8    Anhang

    59 8 anhang 8.2.3 sps-schnittstellen xs 5 für steuergerät 97123 und xs 9 für steuergerät 97103 (interne spannungsversorgung) 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 10 11 12 13 14 15 1 2 3 4 2 3 1 4 1 1 1 1 1 2 2 2 2 2 1 2 gnd fertig fehler start zurück- setzen tank nachfüllen tank lee...

  • Page 60: 8    Anhang

    60 8 anhang 8.2.4 sps-schnittstellen xs 5 für steuergerät 97123 und xs 9 für steuergerät 97103 (externe spannungsversorgung) 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 + 24vdc 10 11 12 13 14 15 10 11 12 13 14 15 1 2 3 4 2 3 1 4 1 1 1 1 1 2 2 2 2 2 1 2 gnd 0 vdc/gnd fertig fehler start zur ck- setzen tank n...

  • Page 61: 8    Anhang

    61 8 anhang 8.3 konformitätserklärung konformitätserklärung im sinne der eu richtlinie über elektromagnetische verträglichkeit 89/336/ewg, anhang i hersteller henkel loctite deutschland gmbh arabellastraße 17 d81925 münchen erklärt, dass das nachfolgend bezeichnete gerät aufgrund seiner konzipierung...

  • Page 62

    Henkel loctite deutschland gmbh arabellastraße 17 telefon 0 89/92 68-0 d-81925 münchen telefax 0 89/9 10 19 78 henkel corporation 2005 c.