- DL manuals
- M Design
- Indoor Fireplace
- LUNA 550 DV Gold Gas
- Installation And Use Instructions Manual
M Design LUNA 550 DV Gold Gas Installation And Use Instructions Manual
Summary of LUNA 550 DV Gold Gas
Page 1
Luna 850 v / 550 v gold gas luna 850 dv / 550 dv gold gas instruction for installation and use passion for fire english 09-2011.
Page 2: M - D E S I G N
Instruction for installation and use - luna 1000-1150-1300-1600 h gold - gas m-design 2 v e r y i m p o r ta n t i n s ta l l at i o n i n s t r u c t i o n s f o r t h e m - d e s i g n g a s f i r e p l a c e s t h e s u p p l i e r ta k e s n o r e s p o n s b i l i t y f o r a n y p o s s i b l ...
Page 3
Instruction for installation and use - luna 1000-1150-1300-1600 h gold - gas m-design 3 summary 1. General remarks .............................................................. 5 2. Connection .......................................................................... 5 3. Installing the fireplace ....
Page 4
Instruction for installation and use - luna 1000-1150-1300-1600 h gold - gas m-design 4 open closing key if some dust or waste is seen on the window ( inside and outside ), clean this before the first use of the fireplace. Open and close the door.
Page 5
Instruction for installation and use - luna 1000-1150-1300-1600 h gold - gas m-design 5 1. General remarks this is a moulding of the closed combustion system, designed for the atmosphere and comfort of your living-room. It constitutes an efficient source of heat and gives the impression of a real ch...
Page 6
Instruction for installation and use - luna 1000-1150-1300-1600 h gold - gas m-design 6 3. Installing the fireplace after having checked the appliance, you ready to install your appliance. This is done as follows 3.1.1 positioning the fireplace place the fireplace on a stable surface using the adjus...
Page 7
Instruction for installation and use - luna 1000-1150-1300-1600 h gold - gas m-design 7 4. Installing the chimney install the concentric flue duct as indicated by ontop - metaloterm. The only authorised pipes are ontop metaloterm™. Ontop-metaloterm tested our fireplace with their conduct and we only...
Page 8
Instruction for installation and use - luna 1000-1150-1300-1600 h gold - gas m-design 8 fig. 1 fig. 1 roof exit ( c31 ) tab. 2 this is recommanded with a roof exit tab. 1 this is recommanded with a roof exit > 3m Ø 150/100 appliance c (min) c (max) restrictiion hr+ (as from 4m) luna 850 v / 550 v 3 ...
Page 9
Instruction for installation and use - luna 1000-1150-1300-1600 h gold - gas m-design 9 fig. 2 fig. 2 roof exit via existing chimney (c 31s ) tab. 1 tab. 2 it is obligatory to use the sanitation set ussan with placing. This ussan piece must be saeled at the roof. * * ou/of usdhc10 usdhc13 flex 100 o...
Page 10
Instruction for installation and use - luna 1000-1150-1300-1600 h gold - gas m-design 10 Ø 150/100 with reduction usvk13 on the aplliance appliance a (min) b (min) b (max) restriction hr+ 850 v / 550 v 1,25m wall exit a+0,5m Ø 75 850 dv / 550 dv 1,25 wall exit a Ø 75 (a) Ø 200/130 in combination wit...
Page 11
Instruction for installation and use - luna 1000-1150-1300-1600 h gold - gas m-design 11 Ø 200/130 appliance a (min) b (min) restriction hr+ b (max) 850 v / 550 v 1,25m wall exit Ø 75 a+8m 850 dv / 550 dv 1,25 wall exit Ø 75 a+7m 3° important : be carefull every horizontal part does not have an nega...
Page 12
Instruction for installation and use - luna 1000-1150-1300-1600 h gold - gas m-design 12 fig. 5 roof exit with 90° bends caution : if the vertical lenght is over 3 meter longer than the horizontal lenght, you will need to place a reduction ring of Ø 60. Appliance Ø 150/100 and Ø 200/130 850 v / 850 ...
Page 13
Instruction for installation and use - luna 1000-1150-1300-1600 h gold - gas m-design 13 pic. 1 pic. 2 pic. 3 referential distances in regards to finishing the mantlepiece a very essential point when setting up the luna gold is that the distance has to be respected inbetween fireplace and the finish...
Page 14
Instruction for installation and use - luna 1000-1150-1300-1600 h gold - gas m-design 14 the enclosure of the furnace must be provided with ventilation grills or openings allowing for the elimination of heat by con- vection. It is possible to have a convection kit fitted with the furnace. This syste...
Page 15
Instruction for installation and use - luna 1000-1150-1300-1600 h gold - gas m-design 15 out in out in or inlet inlet design grill ( outlet ) 2 dm² 4 dm².
Page 16
Instruction for installation and use - luna 1000-1150-1300-1600 h gold - gas m-design 16 you have to connect at least two appertures situated at the top of the appliance. Ures. The stove may not be placed direct on the stove may not be placed direct on the floor, wthout the feets. This to allow natu...
Page 17
Instruction for installation and use - luna 1000-1150-1300-1600 h gold - gas m-design 17 7. Mounting a 3-sided frame first remove the profile that is delivered with the fireplace ( pic. 1 ) the 3 sided frame consist of 3 parts and are assembled to the luna ( pic. 2 ) the 3 sides frame and his 3 part...
Page 18
Instruction for installation and use - luna 1000-1150-1300-1600 h gold - gas m-design 18 8. Putting in place the logs, diamond, sapphire and white stones • please check that the pilot light is switched off and that the furnace has cooled down. • move the window to the front by pulling it. The window...
Page 19
Instruction for installation and use - luna 1000-1150-1300-1600 h gold - gas m-design 19 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1 2 11 10 12 3 1 4 5 8 6 7 9 14 13 luna 850v / 850dvgas.
Page 20
Instruction for installation and use - luna 1000-1150-1300-1600 h gold - gas m-design 20 luna 850v 850dv gas.
Page 21
Instruction for installation and use - luna 1000-1150-1300-1600 h gold - gas m-design 21 luna 850 v gas / gaz only for 850v with two burners seulement pour appareil 850v avec deux brûleurs en escaliers.
Page 22
Instruction for installation and use - luna 1000-1150-1300-1600 h gold - gas m-design 22 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 luna 550 v / 550 dv gas.
Page 23
Instruction for installation and use - luna 1000-1150-1300-1600 h gold - gas m-design 23 1 2 3 4 5 6 7 8 luna 550 v / 550 dv gas.
Page 24
Instruction for installation and use - luna 1000-1150-1300-1600 h gold - gas m-design 24 9. First-time use the masonry and plaster surrounding a recently installed furnace hold a great deal of moisture, which must first evaporate before commissioning the appliance. If not, the plaster may crack or s...
Page 25
Instruction for installation and use - luna 1000-1150-1300-1600 h gold - gas m-design 25 11. Startpilot the m-design gas appliance are provided with “constant startpilot”. After the first use or when the winterperiod is coming and you use the fireplace daily, you must let the startpilot switch on. D...
Page 26
Instruction for installation and use - luna 1000-1150-1300-1600 h gold - gas m-design 26 13. Specification sheet type of gas natural gas butane-propane / lpg category i 2h i 2l i 2e+ i 2e i 3+ i 3b/p category g25 g20 g31 g30 type c 11 , c 31 , c 31s c 11 , c 31 , c 31s c 11 , c 31 , c 31s c 11 , c 3...
Page 27
Instruction for installation and use - luna 1000-1150-1300-1600 h gold - gas m-design 27 type of gas natural gas butane-propane / lpg category i 2h i 2l i 2e+ i 2e i 3+ i 3b/p category g25 g20 g31 g30 type /type c 11 , c 31 , c 91 c 11 , c 31 , c 91 c 11 , c 31 , c 91 c 11 , c 31 , c 91 entry pressu...
Page 28
Instruction for installation and use - luna 1000-1150-1300-1600 h gold - gas m-design 28 luna 850 v gold gas.
Page 29
Instruction for installation and use - luna 1000-1150-1300-1600 h gold - gas m-design 29 luna 850 dv gold gas.
Page 30
Instruction for installation and use - luna 1000-1150-1300-1600 h gold - gas m-design 30 luna 550 v gold gas.
Page 31
Instruction for installation and use - luna 1000-1150-1300-1600 h gold - gas m-design 31 luna 550 dv gold gas.
Page 32
Instruction for installation and use - luna 1000-1150-1300-1600 h gold - gas m-design 32 min. Distance between appliance and maconery : 4cm x = inside measurement frame ( finished size ) y = measurment from underneath 4th side frame till upper side frame above window 4 mm = thickness frame 2 mm = ga...
Page 33
Instruction for installation and use - luna 1000-1150-1300-1600 h gold - gas m-design 33 min. 4cm min. 5mm inlet convection: obliged ! Example how to mount without a 4-sided frame two flexible tubes can be connected to one design grid ( 2 connections ) connecting flex tubes 1000h/1150h/1300h : 2x ( ...
Page 34
Instruction for installation and use - luna 1000-1150-1300-1600 h gold - gas m-design 34 4-sided frame x = 3,5 cm x = 7 cm x = 10,5 cm onderlat / baguette 35 70 105 z x detail z.
Page 35
Instruction for installation and use - luna 1000-1150-1300-1600 h gold - gas m-design 35 14. Spare parts x = 850v, 550v, gs-x typ 14-00 gs 02-10 gs-26-00 gs-x 02-00-00 gs-x 15-00 gs-x typ 03-04-00 gs-x typ 03-03-00 gs-x typ 03-00-00 gs typ 02-12 gs-x typ 28-00 gs-x typ 25-00 gs-typ 05-00 gs 06-04 gs...
Page 36
Instruction for installation and use - luna 1000-1150-1300-1600 h gold - gas m-design 36 14. Spare parts x = 850dv, 550dv.
Page 37
Instruction for installation and use - luna 1000-1150-1300-1600 h gold - gas m-design 37 15. Guarantee this page is your warranty card. The guarantee is only valid for faults caused by construction defects or defects in the parts used to build the furnace. M-design offers a 12 month guarantee on all...
Page 38
Instruction for installation and use - luna 1000-1150-1300-1600 h gold - gas m-design 38.
Page 39
Instruction for installation and use - luna 1000-1150-1300-1600 h gold - gas m-design 39.